logo
Rumah ProdukPompa hidraulik Rexroth

A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump

I 'm Online Chat Now

A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump

A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump
A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump

Gambar besar :  A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump

Detail produk:
Tempat asal: Jerman
Nama merek: Rexroth
Sertifikasi: ISO
Nomor model: A4VSO250DRG/30L-PPB13N00
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Kemasan rincian: kotak kayu
Waktu pengiriman: 2 minggu
Syarat-syarat pembayaran: Western Union,T/T,D/P,D/A,L/C
Menyediakan kemampuan: 100

A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump

Deskripsi
Tipe Poros: Poros Kunci Paralel (DIN 6885) Arah Rotasi: L = Berlawanan Arah Jarum Jam (CCW)​ — dilihat dari ujung poros
Flensa Pemasangan: ISO 3019-2 (4 baut, metrik) Konfigurasi Pelabuhan: PPB13: Port bergelang SAE, sekrup metrik, pelat port Seri 13
Melalui Drive: N00 = Tidak ada through-drive​ (tidak dapat memasang pompa bantu di belakang)

A4VSO250DRG/30L-PPB13N00 — Variable Displacement Axial Piston Pump (A4VSO Series, Open Circuit)

⚠️ Important:​ A4VSO is a hydraulic pump (not a motor)​ for mineral oil hydraulic systems only. It cannot pump water and must not be run dry or in reverse rotation.


📋 Parameter Specification Table

Parameter Category

Parameter

Specification / Description

General Information

Manufacturer / Series

Rexroth (Germany), A4VSO​ Open Circuit Variable Axial Piston Pump


Full Model Code

A4VSO250DRG/30L-PPB13N00


Functional Summary

250 cm³ displacement · DRG Pressure Compensator w/ Remote Pilot Option · CCW Rotation · PPB13 Ports · No Through-Drive

Hydraulic Performance

Geometric Displacement

250 cm³/rev (≈ 15.3 in³/rev)


Nominal Continuous Pressure

350 bar (≈ 5075 psi)


Peak Intermittent Pressure

400 bar (≈ 5800 psi)


Recommended Speed Range

1000 – 1500 rpm​ (Max ~1800 rpm subject to inlet conditions)


Theoretical Flow @ 1500 rpm

250 × 1500 ÷ 1000 = 375 L/min


Control Type

DRG — Pressure Compensator (Constant Pressure Control) with Remote Pilot Port (X):
• Local mechanical screw sets max pressure
• Port X accepts external pilot pressure to reduce/override setpoint
• Below set pressure → full displacement; at set pressure → de-strokes to maintain pressure

Mechanical Interface

Shaft Type

Parallel Key Shaft (DIN 6885)


Rotation Direction

L = Counter-Clockwise (CCW)​ — viewed from shaft end


Mounting Flange

ISO 3019-2 (4-bolt, metric)


Port Configuration

PPB13: SAE flanged ports, metric screws, Series 13 port plate


Through Drive

N00 = No through-drive​ (cannot mount auxiliary pump on rear)

Seals & Media

Seal Material

NBR (Nitrile Rubber)​ — standard for mineral oil


Compatible Fluids

Mineral oils (HL/HLP), HFC (Water Glycol with derating); NOT HFD unless FKM-sealed


Oil Temperature Range

−20 °C to +70 °C (with NBR seals)


Fluid Cleanliness Required

ISO 4406 17/15/12​ or cleaner (NAS 1638 Class 7 equivalent)

Physical Data

Approximate Weight

135 kg


Case Drain Ports

2 × G1/2 (use one to tank, plug the other; backpressure ≤ 0.5 bar)


Recommended Suction Line

≥ DN50/DN65, short & straight, with 100 mesh (149 µm) suction strainer

A4VSO250DRG/30L-PPB13N00 Rexroth Germany original A4VSO250 series hydraulic piston pump  0

A4VSO250DR/30R-PKD63N00E
A4VSO250DR/30R-PKD63N00ESO103
A4VSO250DR/30R-PKD63N00ESO103
A4VSO250DR/30R-PKD63N00ESO103
A4VSO250DR/30R-PKD63N00ESO127
A4VSO250DR/30R-PPB13N00
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00E
A4VSO250DR/30R-PPB13N00ESO103
A4VSO250DR/30R-PSD63K38E
A4VSO250DR/30R-PSD63N00
A4VSO250DR/30R-PSD63N00E
A4VSO250DR/30R-VKD63K05E
A4VSO250DR/30R-VKD63N00
A4VSO250DR/30R-VKD63N00E
A4VSO250DR/30R-VKD63N00E
A4VSO250DR/30R-VKD63N00E
A4VSO250DR/30R-VKD63N00E
A4VSO250DR/30R-VKD63N00E
A4VSO250DR/30R-VKD63N00ESO19
A4VSO250DR/30R-VKD75K07ESO886
A4VSO250DR/30R-VKD75U99E
A4VSO250DR/30R-VKD75U99E
A4VSO250DR/30R-VKD75U99ESO103
A4VSO250DR/30R-VKD75U99ESO103
A4VSO250DR/30R-VSD75U18E
A4VSO250DR/30R-VSD75U99E
A4VSO250DR/30R-VSD75U99E
A4VSO250DR/31R-VKD75K07E
A4VSO250DRG/30R-FKD75U99E
A4VSO250DRG/30R-PKD63K21E
A4VSO250DRG/30R-PKD63K22E
A4VSO250DRG/30R-PKD63K22ESO580
A4VSO250DRG/30R-PKD63K22ESO580
A4VSO250DRG/30R-PKD63K22-SO580
A4VSO250DRG/30R-PKD63N00E
A4VSO250DRG/30R-PKD63N00E
A4VSO250DRG/30R-PKD63N00-SO91
A4VSO250DRG/30R-PKD63N00-SO91
A4VSO250DRG/30R-PPB13N00
A4VSO250DRG/30R-PPB13N00E
A4VSO250DRG/30R-PPB13N00E
A4VSO250DRG/30R-PPB13N00E
A4VSO250DRG/30R-PPB13N00E
A4VSO250DRG/30R-PPB13N00E
A4VSO250DRG/30R-PPB25N00
A4VSO250DRG/30R-PSD63K24-SO859
A4VSO250DRG/30R-VKD63N00
A4VSO250DRG/30R-VKD63N00
A4VSO250DRG/30R-VKD75U99E-SO206
A4VSO250DRG/30R-VSD75U18E
A4VSO250DRG/30R-VSD75U18E
A4VSO250DRG/30R-VSD75U99E
A4VSO250DRG/30R-VSD75U99E



🔍 Model Code Br

eakdown

A4VSO  250   DRG  /   30   L   -   PPB13   N00
 │      │     │        │   │       │       └── No through-drive
 │      │     │        │   │       └── PPB13: SAE flanged / metric screws / Series 13
 │      │     │        │   └── L: Counter-Clockwise (CCW) viewed from shaft end
 │      │     │        └── 30: Series code (size group / design generation)
 │      │     └── DRG: Pressure Compensator + Remote Pilot Port X (local adj. sets max; pilot can lower it)
 │      └── 250 cm³/rev geometric displacement
 └── A4VSO: Open Circuit Variable Axial Piston Pump (Heavy-Duty Industrial)

FAQ — Frequently Asked Questions (In-Depth)


Q1: What is "DRG" control and how is it different from plain "DR" or "DFR"?

A:

  • DR (basic):​ Pressure compensator with local mechanical adjustment only. Set screw determines the cutoff pressure; no external influence possible.

  • DRG (this model):​ Same pressure compensator PLUS a pilot port (X). The local screw sets the maximumpressure; an external pilot signal (e.g., from a hand pump, pneumatic pilot valve, or proportional reducing valve) can reduce the effective setting​ — i.e., pilot pressure at X subtractsfrom the local spring setting. Useful when you need to change the pump's pressure cap electrically/pneumatically or from a remote station.

  • DFR / LR2:​ Adds Load Sensing (LS)​ function — pump tracks valve-bank LS signal with a fixed ∆p. DRG has no LS; it's purely a remotely-influenceable pressure limiter.

  • When to choose DRG:​ You need a simple pressure-limited pump but also want the ability to remotely lower/modulate the pressure setpoint (e.g., energy save mode, multi-stage pressure system) without a full LS setup.


Q2: The rotation code is "L" (30L) — how do I verify and what if it's wrong?

A:

  • L = Counter-Clockwise (CCW):​ Face the drive shaft end (coupling side looking into the pump); the shaft must rotate counter-clockwise.

  • Check motor rotation arrow or perform a brief jog test before final coupling.

  • Running in reverse on an L pump:

    • Port plate suction/pressure windows are asymmetrical → suction failure → cavitation/seizure

    • Internal lubrication galleries are directional → immediate loss of lube film

    • Damage is near-instantaneous → total pump destruction

    • Correct by re-phasing motor or ordering an "R" (clockwise) version — never force reverse run.


Q3: What are the suction (inlet) requirements for this 250 cc pump?

A:

  1. Minimum absolute inlet pressure ≥ 0.8 bar​ (gauge ≈ −0.2 bar vacuum max).

  2. For sustained 1500+ rpm, a boost pump​ providing 1.0–1.5 bar positive head is recommended for margin.

  3. Suction line:

    • Inner diameter ≥ DN50 (DN65 preferred)

    • Length as short as possible (< 1.5 m), minimize elbows

    • 100 mesh (149 µm) suction strainer with < 0.05 bar pressure drop

  4. Tank outlet submerged ≥ 300 mm or above pump inlet.

    Cavitation symptoms: high-pitched whine, valve plate pitting, flow drop, premature bearing failure.


Q4: Can I mount a gear pump on the rear for charge/pilot pressure?

A:No.​ The suffix N00​ = no through-drive shaft. Rear housing is blanked. If you need a through-drive for an auxiliary pump, select a version with through-drive code such as K01, K02, K51, etc. For DRG you typically still need a separate pilot pressure source for port X if remote control is used.


Q5: How must the case drain (L port) be plumbed?

A:

  • Connect one case drain port​ via a dedicated line directly to the tank​ (above oil level or looped to prevent siphon).

  • Backpressure ≤ 0.5 bar (ideally 0 bar). Plug the unused drain port.

  • Never:​ block it, tie it into a pressurized return line, or share a small-bore return with other valves.

  • Result of neglect:​ Housing pressurizes → shaft seal blowout, valve plate distortion, bearing overheating → pump fails.


Q6: What drive motor power is required?

A:​ At 350 bar / 1500 rpm / full displacement:

  • Hydraulic power Pₕ = (250 × 10⁻⁶ × 350 × 1500) ÷ 600 ≈ 219 kW

  • With ηₘₑcₕ ≈ 0.90 → shaft input ≈ 243 kW

Recommended drive:250 kW (≈335 HP)​ electric motor, S1 duty, with adequate starting torque for 400 bar peak. Avoid prolonged operation below ~750 rpm minimum continuous speed.


Q7: Are NBR seals OK with HFC or HFD fluids?

A:

  • HFC (Water Glycol):​ NBR acceptable with pressure/temperature derating per Rexroth (typically ×0.8 pressure factor, watch Tmax).

  • HFD (Phosphate Ester):​ NBR will swell → must specify FKM (Viton) seal version​ (/V suffix or explicit FKM option).

  • Standard mineral oil (HL/HLP) → no issue with NBR.


Q8: What are the key commissioning steps?

A:

  1. Fill & bleed:​ Loosen case drain and HP port bleed screw. Hand-rotate shaft while filling till oil flows bubble-free.

  2. Verify case drain line​ is open to tank.

  3. Jog-test rotation​ — confirm CCW (L), no abnormal noise.

  4. Low-pressure run-in:​ Back off DR adjustment screw (minimum pressure); run briefly to purge air from system and lines.

  5. Set pressure:​ Slowly turn DR screw clockwise to desired max pressure. If using pilot port X, verify remote lowering function.

  6. Lock & document:​ Tighten lock nut on DR adjuster; record both local and (if applicable) pilot-influenced settings.