제품 상세 정보:
|
| 최대. 조정 가능한 압력: | 200 바 | 압력 조정 범위: | 대략. 5~200바 |
|---|---|---|---|
| 공칭 크기: | 10mm | 모델: | DR 10-5-5X/200YM |
| 주문번호: | R900598358 |
|
Parameter |
Specification |
|---|---|
|
Model |
DR 10-5-5X/200YM |
|
Order No. |
R900598358 |
|
Type |
Pilot-Operated, Screw-In Relief Valve |
|
Function |
Pressure Limiting/Relief |
|
Nominal Size |
10 mm |
|
Max. Adjustable Pressure |
200 bar |
|
Pressure Adjustment Range |
Approx. 5 to 200 bar |
|
Port Designation |
P (Pressure Inlet), T (Tank Outlet) |
|
Port Thread |
P and T: 7/8" - 14 UNF |
|
Mounting Interface |
Cartridge Style, Screw-In (ISO 7368) |
|
Pressure Adjustment |
Via Pilot Stage Screw with Lock Nut |
|
Max. Flow Capacity |
Up to 100 L/min (depending on pressure setting) |
|
Pilot Stage Type |
Direct-Acting |
|
Main Stage Type |
Hydraulically Balanced Piston |
|
Standard Seal Material |
FKM (Viton) |
|
Suitable Media |
Mineral Oils (HL, HLP per DIN 51524) |
|
Media Temperature Range |
-20°C to +80°C |
|
Media Viscosity Range |
10 to 400 mm²/s |
|
Hysteresis |
≤ ±5% of set pressure |
|
Leakage |
Very Low Internal Leakage in Closed State |
![]()
| DR20-4-5X/200YM |
| DR20-5-5X/50YM |
| DR10DP2-4X/75Y |
| DR10DP2-4X/75YM |
| DR10DP2-4X/25YM |
| DR30-4-5X/315YM |
| DR10-4-5X/315YM |
| DR10DP1-4X/75YM |
| DR10DP2-4X/210YM |
| DR30-5-5X/50YM |
| DR30-5-5X/50Y |
| DR10-5-5X/200Y |
| DR10-5-5X/50Y |
| DR20-4-5X/200Y |
| DR30-5-5X/350YM |
| DR30-4-5X/200Y |
| DR20-5-5X/200YV |
| DR30-6-5X/50YM |
| DR25G5-5X/200YM |
| DR30-5-5X/200YV |
| DR30-4-5X/200YM |
| DR30-5-5X/200YMV |
| DR10-7-5X/100Y |
| DR20-5-5X/50YV |
| DR10G4-5X/50YM |
| DR20-5-5X/315YMV |
| DR20-4-5X/50Y |
| DR20-7-5X/200YM |
| DR20-7-5X/200Y |
| DR30-7-5X/200YM |
| DR6DP7-5X/210YM |
| DR6DP7-5X/25YM |
| DR6DP2-5X/315YM |
| DR20K7-1X/200YM |
| DR30-5-5X/100Y |
| DR30-5-5X/200Y |
| DR10-4-5X/200Y |
| DR20-4-5X/315Y |
| DR20-4-5X/100Y |
| DR20-5-5X/315YM |
| DR10-4-5X/315Y |
| DR10-5-5X/100Y |
| DR30-5-5X/315YM |
| DR20-4-5X/100YM |
| DR10-4-5X/200YM |
| DR10-5-5X/315Y |
| DR30-4-5X/315Y |
| DR20-5-5X/315Y |
| DR30-5-5X/100YMV |
| DR10-5-5X/315YM |
| DR30-5-5X/200YM |
| DR10-5-5X/100YM |
| DR20-5-5X/100Y |
| DR20-5-5X/200YM |
Q: This valve is rated for 200 bar. How does that compare to the 100YM model?
A: The primary difference is the maximum adjustable pressure. The DR10-5-5X/200YM can be set up to 200 bar, while the DR10-4-5X/100YM is limited to 100 bar. The internal pilot spring in the 200YM model is calibrated for this higher force range. The nominal size, flow capacity, and basic function are otherwise similar. Always select the valve whose maximum rating meets or exceeds your system's required relief pressure.
Q: The model number includes a "5-5X" code. What does this signify?
A: This is a Rexroth internal design variant code. The number ("5" in this case) following the size designation typically indicates a specific series or generation within the DR10 family, which may involve differences in performance, internal damping, or construction details. The "5X" suffix provides further specification on the exact configuration. For precise technical data (like the pressure-flow curve), you must refer to the official datasheet for this specific variant.
Q: How does the pilot-operated design benefit performance compared to a direct-acting valve?
A: The pilot-operated design offers two main advantages: 1) Minimal Pressure Override: The pressure required to pass full flow is very close to the cracking pressure, resulting in a flatter pressure-flow curve. This provides more precise system pressure control, especially at high flows. 2) Low Leakage: In the closed position, the main piston provides a tight seal, leading to lower internal leakage and better energy efficiency compared to a direct-acting poppet that may have slight leakage.
Q: The valve is making a high-frequency chattering noise. What could be the cause?
A: Chattering in a pilot-operated relief valve is often caused by instability in the pilot stage. Common reasons include: 1) Contamination: Dirt in the small pilot orifice or on the pilot poppet seat. 2) Air in the System: Entrained air can cause the pilot stage to oscillate. 3) Excessive System Pulsation: Pressure spikes from the pump can trigger the pilot stage repeatedly. 4) Incorrect Setting: Operating too close to the system's normal working pressure. Solutions include checking fluid cleanliness, bleeding air, installing a pulsation damper, or increasing the margin between working and relief pressure.
Q: Is a special manifold required to install this screw-in cartridge valve?
A: Yes. This valve requires a precision-machined mounting cavity in a manifold block or subplate. The cavity must conform to the ISO 7368 standard for Size 10 cartridges. The design includes specific dimensions, sealing grooves, and port connections for P and T. The valve is inserted into this cavity and secured with a retaining screw or cover plate. It cannot be installed in a standard threaded port.