Product Details:
|
Pressure: | High Pressure | Certifisaarion: | ISO9001 |
---|---|---|---|
Max Pressure: | 350 Bar | Pump: | Rexroth |
After Serive: | Online Video | Pressure Rating: | 280 Bar |
Standard Or Nonstandard: | Standard | Structure: | Gear Pump |
Material No: | R910998495 R902418985 |
A10VSO71DFR1/31R-PPA12N00 A10VSO71DFR1/32R-VPB12N00 Rexroth Germany hydraulic piston pump hydraulic oil pump
85267220981 | yli97584@gmail.com | ||
Brand Name | Rexroth | Place of Origin | fujian, China |
Warranty | 12 Months | Video outgoing-inspection | Provided |
Machinery Test Report | Provided | Application | Machinery Repair Shops |
Material | Iron | Condition | Oringal |
Type | A10VSO71DFR1/31R-PPA12N00 A10VSO71DFR1/32R-VPB12N00 | Quality | 100% Tested Great Performance |
Certification | ISO | Feature | Long Life Low Noise |
Function | Filter Diesel Oil | Power | Hydraulic Power |
Payment Term | T/T 100% |
R900224261 A10VSO71DFLR/31R-PPA12N00 (18,5-1750) |
R910075790 A10VSO71DFR + 1PF2G3-3X/038 |
R900216412 A10VSO71DFR/31L-PPA12N00 |
R900220486 A10VSO71DFR/31R-PPA12K27 |
R902419050 A10VSO71DFR1 + 1PF2G2-4X/022 |
R900302498 A10VSO71DFR1/31R-PPA12K01 -W3CS (RINA) |
R900020891 A10VSO71DFR1/31R-PPA12K25 |
R900571887 A10VSO71DFR1/31R-PPA12K27 |
R902411514 A10VSO71DFR1/31R-PPA12KB3 SO127 |
R900230411 A10VSO71DFR1/31R-PPA12N00 SO135 |
R900573819 A10VSO71DFR1/31R-PPA12N00 SO169 |
R900225180 A10VSO71DFR1/31R-PSA12K02 SO126 |
R900220377 A10VSO71DFR1/31R-PSA12KB4 SO13 |
R900216691 A10VSO71DR + G3-3X/026 |
R900219977 A10VSO71DR/31L-PPA12N00 |
R900228432 A10VSO71DR/31R-PPA12K25 |
R900241051 A10VSO71DR/31R-PPA12N00 -W31B |
R900227044 A10VSO71DR/31R-PSA12C14 |
R902427942 A10VSO71DRG/31R+A10VSO28DRG/31R |
R900572999 A10VSO71DRG/31R-PPA12K26 |
R900063552 A10VSO71DRG/31R-PPA12K51 |
FAQ:
• Reason:
Excessive resistance in the oil suction pipeline (such as clogged oil filter, low oil tank level, or air leakage in the inlet pipe).
Internal leakage of the pump (scratches on the oil distribution plate, poor sealing, sand holes, etc.).
The inclination angle of the inclined plate is too small and the displacement is insufficient.
Motor reversal (requires adjustment of phase sequence).
• Solution:
Clean the oil filter, add oil to the normal liquid level, and check the sealing of the pipeline.
Replace worn parts (such as plungers, oil distribution plates) or grind mating surfaces.
Adjust the variable piston to increase the inclination angle of the inclined plate.
2. How to adjust if there is still traffic output at the median level?
Reason: Deviation, looseness, or wear of the control mechanism (such as wear of the inclined plate ear shaft).
Solution: Reset the controller, tighten or replace damaged parts, and check the angle holding force.
How to troubleshoot the high vibration and noise during pump operation?
• Mechanical reasons:
The pump and motor shaft are not concentric, the coupling is damaged, or the bolts are loose.
Wear of bearings or variable head bearings (dry friction or impurities in the oil during start-up).
• Hydraulic reasons:
The oil inlet pipe is too thin, the oil filter is clogged, or the oil viscosity is too high.
• Solution:
Reinstall and replace worn parts.
Select appropriate oil to ensure smooth fuel tank design and piping.
What are the causes and solutions for overheating of the pump body?
Contact Person: Mr. liyun