Produktdetails:
|
| Teilenummer: | R900410875 | Modell: | ZDR 10 - DP2 - 5X / 75YM |
|---|---|---|---|
| Max. Einstellbarer reduzierter Druck: | 75 bar (einstellbarer Bereich typischerweise 3–75 bar – Niederdruckstufe) | Flüssigkeitstemperaturbereich: | -20 °C bis +90 °C (FKM-Dichtungen) |
| Viskositätsbereich: | 10–800 mm²/s |
|
Parameter |
Value |
|---|---|
|
Part Number |
R900410875 |
|
Model |
ZDR 10 - DP2 - 5X / 75YM |
|
Valve Type |
Direct-acting, 3-way pressure reducing valve (sandwich / stackable) |
|
Nominal Size (NG) |
10 — sandwich mounting per ISO 5781 / NG10 (DIN 24340 Form E) |
|
Function |
Reduces & maintains pressure in secondary circuit to set value; 3-way action (excess pressure dumped via external drain) |
|
Adjustment Type |
DP2 = Rotary hand knob with protective cap (hand-adjustable, no tool — NG10 sandwich version) |
|
Component Series |
5X (series 50–59, dimensionally interchangeable) |
|
Max. Adjustable Reduced Pressure |
75 bar (adj. range typically 3–75 bar — low-pressure stage) |
|
Max. Operating Pressure (Primary P-port) |
315 bar |
|
Max. Operating Pressure (Secondary port) |
315 bar |
|
Max. Flow Rate (Qmax) |
approx. 120–150 L/min (Size 10 ZDR) |
|
Pilot Oil Drain |
Y = External pilot drain (separate Y-port to tank) |
|
Seal Material |
M = FKM (Viton) — specified by "M" suffix |
|
Hydraulic Fluid |
Mineral oil HL, HLP; HEES, HETG (bio-oils — FKM recommended); HFC (short-term OK, NBR preferred for prolonged HFC) |
|
Fluid Temperature Range |
-20 °C to +90 °C (FKM seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
3.3 kg |
|
Body Material |
Cast iron / steel, zinc-plated |
![]()
| R901387787 4WRPEH6CB04L-2X/G24K0/C6V |
| R901387788 4WRPEH6C4B40L-2X/G24K0/C6V |
| R901396859 4WRPEH6C3B08L-3X/M/24A1 |
| R901396969 4WRPEH6C3B04L-3X/M/24F1-885 |
| R901402614 4WRPEH6C3B24L-3X/G24K0/A1M=KM |
| R901402817 4WRPEH6C3B24L-2X/G24K0/A1M=KM |
| R901408241 4WRPEH6C5B24L-3X/V/24A1 |
| R901409296 4WRPEH6C3B02L-2X/G24K0/A1M-816=KM |
| R901410492 4WRPEH6C3B40L-3X/M/24A1-15 |
| R901412522 4WRPEH6C4B12L-3X/M/24A1-561 |
| R901422942 4WRPEH6CB40L-3X/V/24F1 |
| R901423624 4WRPEH6C1B24L-3X/V/24A1 |
| R901429091 4WRPEH6CB15P-3X/M/24F1 |
| R901431666 4WRPEH6C4B12L-3X/V/24A1 |
| R901436252 4WRPEH6C1B12L-3X/M/24F1 |
| R901438744 4WRPEH6CB40L-3X/V/24A1 |
| R901445011 4WRPEH6C1B04L-3X/M/24F1 |
| R901P74368 4WRPEH6C3B24L-2X/G24K0/A1M-936 _PT |
| R901P74370 4WRPEH6C3B40L-2XR901174370-PT |
| R901PT0044 4WRPEH6C5B24L-2X/G24K0/A1M |
| R901PT0086 4WRPEH6C3B04L-2X/G24K0/F1M-885 |
| R927000557 4WRPEH6C4B40L-2X/G24K0/A1M |
| R927000622 4WRPEH6C3B12L-2X/G24K0/A1M |
| R927000625 4WRPEH6C3B04L-2X/G24K0/A1M |
| R927000626 4WRPEH6C4B40L-2X/G24K0/A1V |
| R927000627 4WRPEH6C3B24L-2X/G24K0/A1M |
| R927000628 4WRPEH6C4B04L-2X/G24K0/A1M |
| R927000629 4WRPEH6C4B12L-2X/G24K0/A1M |
| R927000630 4WRPEH6C4B24L-2X/G24K0/A1M |
| R927000631 4WRPEH6C3B40P-2X/G24K0/A1M |
| R927000632 4WRPEH6C4B02L-2X/G24K0/A1M |
| R927000633 4WRPEH6C4B40P-2X/G24K0/A1M |
| R927000635 4WRPEH6C3B04L-2X/G24K0/F1M |
| R927000636 4WRPEH6C3B12L-2X/G24K0/F1M |
| R927000637 4WRPEH6C3B24L-2X/G24K0/F1M |
| R927000639 4WRPEH6C3B40L -2X/G24K0/F1M |
| R927000641 4WRPEH6C3B04L-2X/G24K0/B5M |
| R927000642 4WRPEH6C3B24L-2X/G24K0/B5M |
| R927000643 4WRPEH6C3B12L-2X/G24K0/B5M |
| R927000644 4WRPEH6C4B24L-2X/G24K0/B5M |
| R927000645 4WRPEH6C3B40P-2X/G24K0/B5M |
| R927000646 4WRPEH6C3B40L-2X/G24K0/B5M |
| R927000905 4WRPEH6CB40L-2X/G24K0/A1M |
| R927000906 4WRPEH6C3B15P-2X/G24K0/A1M |
| R927000909 4WRPEH6C4B25P-2X/G24K0/A1M |
| R927000910 4WRPEH6C4B15P-2X/G24K0/A1M |
| R927000911 4WRPEH6C1B40L-2X/G24K0/A1M |
| R927000920 4WRPEH6CB04L-2X/G24K0/A1M |
| R927000921 4WRPEH6CB40L-2X/G24K0/F1M |
| R927001152 4WRPEH6C1B40P-2X/G24K0/A1M |
| R927001153 4WRPEH6C3B02L-2X/G24K0/A1M |
| R978714494 4WRPEH6CB40L-2X/G24K0/A1M SO43A-1851 |
| R978714502 4WRPEH6C3B40L-2X/G24K0/A1M SO43A-1850 |
| R978716388 4WRPEH6C3B24L-2X/G24K0/A1M SO43A-1849 |
| 0811404001 4WRP10E63S-1X/G24Z4/M |
| 0811404002 4WRP10W63S-1X/G24Z4/M-791 |
| 0811404003 4WRP10E32S-1X/G24Z4/M |
| 0811404004 4WRP10W32S-1X/G24Z4/M-787 |
| 0811404011 REGELVENTIL |
| 0811404016 WEGEVENTIL |
| 0811404019 4WRP10EA63S-1X/G24K4/M-851 |
| 0811404020 4WRP10E63S-1X/G24Z4/M-850 |
| 0811404021 4WRP10EA63S-1X/G24Z4/M-850 |
| 0811404032 4WRPH6KB50L-2X/G24Z4/M |
| 0811404033 4WRPH6C3B04L-2X/G24Z4/M |
| 0811404034 4WRPH6C3B12L-2X/G24Z4/M |
| 0811404035 4WRPH6C3B24L-2X/G24Z4/M |
| 0811404036 4WRPH6C3B40L-2X/G24Z4/M |
| 0811404037 4WRPH6C4B12L-2X/G24Z4/M |
| 0811404038 4WRPH6C4B24L-2X/G24Z4/M |
| 0811404039 4WRPH6C4B40L-2X/G24Z4/M |
| 0811404040 4WRPH6KB50P-2X/G24Z4/M |
| 0811404041 4WRPH6C3B02L-2X/G24Z4/M |
| 0811404042 4WRPH6C3B04P-2X/G24Z4/M |
Q1: Is ZDR a relief valve / overflow valve?
No. A relief valve (DB/DBD) limits upstream/system pressure; a pressure reducing valve (ZDR) maintains a lower, constantpressure in a downstream (secondary) circuit. If inlet (primary) pressure drops below the set reduced pressure, the ZDR opens fully and passes flow unregulated — it does not protect the pump from overpressure.
Q2: What does "DP2 /75YM" mean?
DP2 = NG10 sandwich, rotary hand knob with protective cap (hand-adjustable).
/75 = spring stage, max. adjustable reduced pressure = 75 bar (low-pressure stage; also available: /150, /210, /315).
Y = external pilot drain — pilot oil returns via separate Y-port to tank, not via the sandwich T-channel.
M = FKM (Viton) seal material.
Q3: How do I adjust the reduced pressure?
With the secondary circuit under flow, lift/remove the cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Verify with a pressure gauge at the secondary port — the knob has no calibrated scale. Factory preset is typically near minimum; fine-tune under operating flow if possible.
Q4: How is the valve mounted?
As a sandwich (stackable) valve between a directional control valve and the NG10 subplate. Uses NG10 DIN 24340 Form E / ISO 5781 bolt pattern (four M10 bolts). Sandwich port IDs: P = primary (high pressure from pump side), A (or B) = reduced secondary pressure to actuator, T = tank return, Y = external pilot drain to tank (must be plumbed separately!).
Q5: Why specify the "Y" (external drain) version?
If the T-line in the valve stack has >2–3 bar backpressure, an internally drained ZDR's set reduced pressure will increase by the amount of T-backpressure. The Y-version drains the pilot independently to tank, keeping the set reduced pressure stable. Always use Y-version if T-backpressure is present or uncertain.
Q6: What is the "M" seal version for?
M = FKM (Viton) seals — for:
Higher fluid temperature (up to ~90 °C)
Biodegradable oils (HEES, HETG — NBR not recommended)
Some HFC applications (short-term; NBR preferred for prolonged HFC exposure)
Not for phosphate ester (HFD) unless specially confirmed.
Q7: Common faults & causes?
Reduced pressure too high / cannot lower: wrong spring stage (e.g. /210 or /315 installed), pilot orifice clogged, Y-drain line blocked (Y-version!), inlet pressure insufficient to allow regulation.
Reduced pressure drifts / unstable: contaminated pilot seat, damaged O-ring on sandwich face causing internal leak, Y-line restricted or pinched.
Excessive heating at T: Normal for 3-way ZDR — some bypass to T occurs to hold set pressure; excessive heat may indicate stuck spool from contamination — flush system & verify filtration (ISO 4406 18/16/13 or better).
Ansprechpartner: Mr. liyun
Telefon: +8615280488899