Dettagli:
|
| Peso.: | ca. 12,6kg | Intervallo di viscosità: | da 20 a 380 mm²/s |
|---|---|---|---|
| Temperatura del supporto: | Da -20°C a +80°C (ottimale 40–50°C) | Supporti adatti: | Oli minerali (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR |
| Interfaccia di montaggio: | ISO 4401-07-07-0-05 (sottopiastra CETOP 7) | ||
| Evidenziare: | Rexroth servo proportional valve,Valvola idraulica Rexroth tedesca,Valvola proporzionale 4WRZE16W8 con garanzia |
||
|
Parametro |
Specificità |
|---|---|
|
Numero d'ordine- Sì. |
R900721116- Sì. |
|
Modello- Sì. |
4WRZE16W8-150-7X/6EG24N9ETK31/F1D3M |
|
Tipo- Sì. |
A pilotaggio, valvola proporzionale di direzione a due fasi |
|
Funzione- Sì. |
4/3-way (3 posizioni, 4 porte), a molla |
|
Tipo di bobina- Sì. |
W8 (spirale di sovrapposizione, caratteristiche specifiche di transizione)- Sì. |
|
Dimensione nominale- Sì. |
NG16(CETOP 7) |
|
Pressione di funzionamento massima- Sì. |
P, A, B:350 barPortata T:210 bar- Sì. |
|
Flusso nominale- Sì. |
150 l/min(a Δp = 10 bar per terreno di controllo) |
|
Max. flusso- Sì. |
Approximativamente.460 l/min- Sì. |
|
Elettronica- Sì. |
Elettronica integrata di bordo (OBE)- Sì. |
|
Tensione di alimentazione- Sì. |
24 V di corrente continua(19.4...35 VDC) |
|
Segnale di controllo- Sì. |
4 ̊20 mA(input di corrente analogica,/F1Suffisso) |
|
Feedback- Sì. |
Sì (LVDT, posizione della bobina a circuito chiuso)- Sì. |
|
Fornitura di olio pilota- Sì. |
Interno (da P)- Sì. |
|
Ritorno dell'olio pilota- Sì. |
Interno (fino a T)- Sì. |
|
Sottoscrizione manuale- Sì. |
Sì (N9, nascosto)- Sì. |
|
Valvola di riduzione della pressione- Sì. |
Sì (D3, ZDR 6 DP0-4X/...)- Sì. |
|
Materiale del sigillo- Sì. |
NBR- Sì. |
|
Collegamento elettrico- Sì. |
con una tensione di 20 V o piùK31) |
|
Interfaccia di montaggio- Sì. |
ISO 4401-07-07-05 (sottopiastra CETOP 7) |
|
Media adatti- Sì. |
Oli minerali (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR |
|
Temperatura del supporto- Sì. |
-20°C a +80°C(optimale 40°C-50°C) |
|
Intervallo di viscosità- Sì. |
Da 20 a 380 mm2/s |
|
Peso- Sì. |
Approximativamente.120,6 kg- Sì. |
![]()
| 4WRZE16EA150-72/6EG24K31/A1M |
| 4WRZE16EA150-72/6EG24K31/F1V |
| 4WRZE16EA150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16EB150-72/6EG24EK31/A1D3V |
| 4WRZE16W6 150-72/6EG24K31/A1M |
| 4WRZE16W6-100-72/6EG24ETK31/A1D3M |
| 4WRZE16W6-100-72/6EG24ETK31/A1D3V |
| 4WRZE16W6-100-72/6EG24ETK31/F1D3V |
| 4WRZE16W6-100-72/6EG24K31/A1M |
| 4WRZE16W6-100-72/6EG24K31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/A1M |
| 4WRZE16W6-100-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/F1D3V |
| 4WRZE16W6-100-72/6EG24N9K31/A1M |
| 4WRZE16W6-100-72/6EG24N9K31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9K31/F1V |
| 4WRZE16W6-100-72/6EG24N9TK31/F1D3M |
| 4WRZE16W6-150-72/6EG24EK31/A1D3M |
| 4WRZE16W6-150-72/6EG24EK31/A1M |
| 4WRZE16W6-150-72/6EG24EK31/A1V |
| 4WRZE16W6-150-72/6EG24EK31/F1D3M |
| 4WRZE16W6-150-72/6EG24ETK31/A1D3M |
| 4WRZE16W6-150-72/6EG24ETK31/A1M |
| 4WRZE16W6-150-72/6EG24ETK31/F1D3M |
| 4WRZE16W6-150-72/6EG24K31/A1D3M |
| 4WRZE16W6-150-72/6EG24K31/A1V |
| 4WRZE16W6-150-72/6EG24K31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1V |
| 4WRZE16W6-150-72/6EG24N9EK31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/F1D3V |
| 4WRZE16W6-150-72/6EG24N9EK31/F1V |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1D3V |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1M |
| 4WRZE16W6-150-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9K31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9K31/A1M |
| 4WRZE16W6-150-72/6EG24N9K31/A1V |
| 4WRZE16W6-150-72/6EG24N9K31/F1D3V |
| 4WRZE16W6-150-72/6EG24N9K31/F1V |
| 4WRZE16W6-150-72/6EG24N9TK31/A1D3M |
| 4WRZE16W8-100-72/6EG24EK31/F1D3V |
| 4WRZE16W8-100-72/6EG24K31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9EK31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9EK31/A1D3V |
| 4WRZE16W8-100-72/6EG24N9EK31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/A1M |
| 4WRZE16W8-100-72/6EG24N9K31/A1V |
| 4WRZE16W8-100-72/6EG24N9K31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/F1V |
| 4WRZE16W8-100-72/6EG24N9TK31/F1M |
| 4WRZE16W8-150-72/6EG24EK31/A1M |
| 4WRZE16W8-150-72/6EG24EK31/F1D3M |
| 4WRZE16W8-150-72/6EG24ETK31/A1D3M |
| 4WRZE16W8-150-72/6EG24ETK31/A1M |
| 4WRZE16W8-150-72/6EG24ETK31/F1D3M |
| 4WRZE16W8-150-72/6EG24K31/A1D3M |
| 4WRZE16W8-150-72/6EG24K31/F1M |
| 4WRZE16W8-150-72/6EG24N9EK31/A1D3M |
| 4WRZE16W8-150-72/6EG24N9EK31/A1D3V |
| 4WRZE16W8-150-72/6EG24N9EK31/A1M |
| 4WRZE16W8-150-72/6EG24N9EK31/F1D3M |
| 4WRZE16W8-150-72/6EG24N9EK31/F1D3V |
| 4WRZE16W8-150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W8-150-72/6EG24N9ETK31/A1M |
| 4WRZE16W8-150-72/6EG24N9ETK31/F1D3V |
| 4WRZE16W8-150-72/6EG24N9ETK31/F1V |
| 4WRZE16W8-150-72/6EG24N9K31/A1D3M |
FAQ:
D: Qual è la differenza principale tra questa valvola e la precedente R900757605?
A:Questa valvola (R900721116) utilizzaRitorno dell'olio pilota interno (a T, codice "ET")Il modello precedente richiedeva un collegamento esterno a Y-port.La contropressione della porta T rimane inferiore a 30 barper garantire il corretto funzionamento della valvola pilota.
D: Cosa significa il suffisso /F1D3M?
A:Il/F1il suffisso indicaInput di corrente di controllo di 4 ′20 mA(ideale per i segnali industriali a prova di rumore)./D3il suffisso indica unValvola riduttrice di pressione integrata (ZDR 6)Per regolare la pressione del pilota./Mil suffisso specificasigilli NBR standard.
D: Come funziona la configurazione dell'olio pilota?
A:Questa valvola (/6EG24N9ETK31) utilizzaapprovvigionamento interno di olio pilota (dal porto principale P) e ritorno interno di olio pilota (al porto principale T)Questa configurazione "ET" è la più conveniente in quanto non richiede linee di pilotaggio esterne, ma è necessario assicurarsi che la contrapposizione della linea principale del serbatoio (porta T) sia controllata.
D: Perché scegliere questa configurazione specifica?
A:Questo modello è ideale perapplicazioni che richiedono un controllo regolare (spole W8) con impianti idraulici semplificati. ilControllo 4 ′20 mA (/F1)offre una buona immunità acustica escarico pilota interno (ET)L'impianto integrato è dotato di un sistema di accensione per il trasporto di energia elettrica./D3 riduttore di pressioneprotegge lo stadio pilota dalle fluttuazioni di pressione del sistema.
D: Qual è la nota di installazione critica?
A:Dal momento che la fase pilota drena internamente a T, sideve garantire che la contropressione della porta T principale sia inferiore a 30 barL'elevata contropressione sulla T può impedire che la valvola pilota si scarichi correttamente, causando un funzionamento irregolare della fase principale.Mantenere un'alta pulizia dell'olio (consigliato per il livello principale di classe 8 o superiore secondo la norma NAS 1638).