logo
제품 소개렉스로스 수압 펌프

A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump

제가 지금 온라인 채팅 해요

A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump

A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump
A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump

큰 이미지 :  A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump

제품 상세 정보:
원래 장소: 독일 사람
브랜드 이름: Rexroth
인증: ISO
모델 번호: A4VSO500DR/30L-PPB13N00
결제 및 배송 조건:
최소 주문 수량: 1
포장 세부 사항: 나무 상자
배달 시간: 2주
지불 조건: 서부 동맹, T/T, D/P, D/A, L/C
공급 능력: 100

A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump

설명
제조사/시리즈​: Rexroth(독일), A4VSO​ 개방형 가변 축 피스톤 펌프 전체 모델 코드​: A4VSO500DR/30L-PPB13N00
기능 요약​: 500cc 변위 · DR 압력 보상기 · 반시계 방향 회전 · PPB13 포트 · 관통 드라이브 없음 기하학적 변위​: 500cm³/rev(≒ 30.5in³/rev)​
공칭 연속 압력​: 350bar(≒ 5075psi)​

Parameter Category

Parameter

Specification / Description

General Information

Manufacturer / Series

Rexroth (Germany), A4VSO​ Open Circuit Variable Axial Piston Pump


Full Model Code

A4VSO500DR/30L-PPB13N00


Functional Summary

500 cc displacement · DR Pressure Compensator · Counter-Clockwise Rotation · PPB13 Ports · No Through-Drive

Hydraulic Performance

Geometric Displacement

500 cm³/rev (≈ 30.5 in³/rev)


Nominal Continuous Pressure

350 bar (≈ 5075 psi)


Peak Intermittent Pressure

400 bar (≈ 5800 psi)


Recommended Speed Range

750 – 1200 rpm​ (Max ~1500 rpm subject to inlet conditions)


Theoretical Flow @ 1200 rpm

500 × 1200 ÷ 1000 = 600 L/min


Control Type

DR — Pressure Compensator (Constant Pressure Control): Below set pressure → full displacement; at set pressure → swashplate de-strokes to maintain pressure

Mechanical Interface

Shaft Type

Parallel Key Shaft (DIN 6885)


Rotation Direction

L = Counter-Clockwise (CCW)​ — viewed from shaft end


Mounting Flange

ISO 3019-2 (4-bolt, metric)


Port Configuration

PPB13: SAE flanged ports, metric screws, Series 13 port plate


Through Drive

N00 = No through-drive​ (cannot mount auxiliary pump on rear)

Seals & Media

Seal Material

NBR (Nitrile Rubber)​ — standard for mineral oil


Compatible Fluids

Mineral oils (HL/HLP), HFC (Water Glycol with derating); NOT compatible with HFD (Phosphate Ester)


Oil Temperature Range

−20 °C to +70 °C (with NBR seals)


Fluid Cleanliness Required

ISO 4406 17/15/12​ or cleaner (equivalent to NAS 1638 Class 7)

Physical Data

Approximate Weight

240 kg


Case Drain Ports

2 × G1/2 (use one to tank, plug the other; backpressure ≤ 0.5 bar)


Recommended Suction Line

≥ DN80/DN100, as short and straight as possible, with 100 mesh (149 µm) suction strainer

A4VSO500DR/30L-PPB13N00 Hydraulic motor, German Rexroth piston pump, water pump  0

A4VSO180DR/30R-PKD63K03
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00E
A4VSO180DR/30R-PKD63N00ESO103
A4VSO180DR/30R-PKD63N00ESO127
A4VSO180DR/30R-PKD63N00-SO127
A4VSO180DR/30R-PPB13N00
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PPB13N00E
A4VSO180DR/30R-PSD63K07E
A4VSO180DR/30R-VKD63I60
A4VSO180DR/30R-VKD63K24
A4VSO180DR/30R-VKD63K70E
A4VSO180DR/30R-VKD63K70E
A4VSO180DR/30R-VKD63N00
A4VSO180DR/30R-VKD63N00E
A4VSO180DR/30R-VKD63N00E
A4VSO180DR/30R-VKD63N00E
A4VSO180DR/30R-VKD75U99E
A4VSO180DR/30R-VKD75U99ESO103
A4VSO180DR/30R-VSD75U99E
A4VSO180DR/30R-VSD75U99E
A4VSO180DRG/22R-PZB13N00
A4VSO180DRG/30R-FKD75U99E
A4VSO180DRG/30R-PKD63K03E
A4VSO180DRG/30R-PKD63K03E
A4VSO180DRG/30R-PKD63K05ESO91
A4VSO180DRG/30R-PKD63K21
A4VSO180DRG/30R-PKD63K21E
A4VSO180DRG/30R-PKD63K21E
A4VSO180DRG/30R-PKD63K21E
A4VSO180DRG/30R-PKD63K38
A4VSO180DRG/30R-PKD63K70E
A4VSO180DRG/30R-PKD63K70E
A4VSO180DRG/30R-PKD63K78
A4VSO180DRG/30R-PKD63N00E
A4VSO180DRG/30R-PKD63N00E
A4VSO180DRG/30R-PPB13N00
A4VSO180DRG/30R-PPB13N00E
A4VSO180DRG/30R-PPB13N00ESO171
A4VSO180DRG/30R-PSD63N00
A4VSO180DRG/30R-PSD63N00ESO91
A4VSO180DRG/30R-VKD63N00
A4VSO180DRG/30R-VKD63N00
A4VSO180DRG/30R-VKD63N00E
A4VSO180DRG/30R-VKD75U99E
A4VSO180DRG/30R-VKD75U99E-SO206
A4VSO180DRG/30R-VSD75U99E
A4VSO180DRGM/30R-EKD63N00
A4VSO180DRGNT/30R-VKD75U99E
A4VSO180DS1/30W-PPB13T041ZE
A4VSO180EM1035/30R-PPB13N00E
A4VSO180EO2/22R-PKD63N00-SO62

🔍 Model Code Breakdown

A4VSO  500   DR   /   30   L   -   PPB13   N00
 │      │    │        │   │       │       └── No through-drive
 │      │    │        │   │       └── PPB13: SAE flanged ports / metric screws / Series 13
 │      │    │        │   └── L: Counter-Clockwise (CCW) viewed from shaft end
 │      │    │        └── 30: Series code (size group / design generation)
 │      │    └── DR: Pressure Compensator (constant pressure), local mechanical adjustment
 │      └── 500 cm³/rev geometric displacement
 └── A4VSO: Open Circuit Variable Axial Piston Pump (Heavy-Duty Industrial)

FAQ — Frequently Asked Questions (In-Depth)


Q1: Can this A4VSO500DR be used as a hydraulic motor? Can it pump water?

A:

  • Not usable as a motor:​ The A4VSO is designed exclusively as a pump for open-circuit operation. Driving it in reverse as a motor will not produce useful torque and will cause internal damage.

  • Strictly prohibited for pumping water:​ Axial piston pumps rely on oil film lubrication between moving parts (pistons/cylinder barrel/valve plate). Water will:

    • Destroy lubrication → immediate seizure of copper-steel friction pairs

    • Cause corrosion and rusting of precision surfaces

    • Swell standard NBR seals, causing leakage

    • For high-pressure water applications, use dedicated plunger pumps or centrifugal pumps — never a hydraulic piston pump.


Q2: What is the difference between DR, DFR, and LR2 control? When should I choose DR?

A:

  • DR (this model):​ Pressure compensator only. Below set pressure → full flow; at set pressure → pump de-strokes to maintain constant pressure (delivering only leakage compensation flow). Best for:​ Simple pressure-limiting systems (presses, power units) where load sensing is not needed.

  • DFR / LR2:​ Adds Load Sensing (LS)​ function. The pump maintains a constant differential pressure (∆p ≈ 14–18 bar) between pump outlet and the LS signal from the valve bank, delivering only the flow demanded by the system. Best for:​ Multi-actuator valve-controlled systems (injection molding, machine tools) where energy saving matters.

  • When to choose DR:​ Your system has no LS signal line, requires only pressure limitation, or simplicity/reliability is prioritized over energy efficiency.


Q3: How do I verify counter-clockwise rotation (30L)? What happens if I run it backward?

A:

  • L = Counter-Clockwise (CCW):​ Facing the drive shaft end (coupling side looking into the pump), the shaft must rotate counter-clockwise.

  • Verify by checking the motor/engine rotation arrow (usually stamped on the fan cover) or perform a brief jog test.

  • Reverse rotation will cause catastrophic failure within seconds:

    • The internal port plate is asymmetrical — reverse rotation misaligns suction and pressure ports

    • Lubrication passages are directional — loss of lubrication causes immediate seizure

    • Cavitation and dry running destroy the cylinder barrel/piston assembly

    • If rotation is wrong, swap motor phases or replace with an "R" (clockwise) pump. Never attempt to run in reverse.


Q4: What are the critical suction (inlet) requirements for this 500 cc pump?

A:​ Large displacement pumps are extremely sensitive to inlet conditions:

  1. Minimum absolute inlet pressure ≥ 0.8–1.0 bar​ (gauge ≈ −0.2 to −0.1 bar max vacuum).

  2. For speeds above 1200 rpm, a boost pump / charge pump​ providing 1.5–2 bar positive head is strongly recommended.

  3. Suction line design:

    • Inner diameter ≥ DN80 (DN100 preferred)

    • Length as short as possible (< 1.5 m), minimize elbows

    • Dedicated 100 mesh (149 µm) suction strainer with pressure loss < 0.05 bar

  4. Tank outlet should be above pump inlet or submersion depth > 300 mm.

    Cavitation symptoms: high-frequency noise, pitting on valve plate, flow reduction, premature bearing failure.


Q5: How should the case drain be connected? What if I ignore it?

A:

  • Case drain carries internal leakage for cooling and flushing wear debris.

  • Must be routed via a dedicated line directly to the reservoir​ (no shared return lines).

  • Backpressure must be ≤ 0.5 bar (ideally 0 bar). The second drain port must be plugged.

  • Never:

    • Block the drain port

    • Connect to a pressurized return line

    • Share a long small-diameter return line with other components

    • Consequence of blocked/pressurized drain:​ Housing pressure buildup → shaft seal blowout, valve plate distortion, bearing overheating, and total pump failure.


Q6: What drive motor power is required?

A:​ At 350 bar / 1200 rpm / full displacement:

  • Hydraulic power Pₕ = (500 × 10⁻⁶ × 350 × 1200) ÷ 600 ≈ 350 kW

  • Including mechanical efficiency (η ≈ 0.90–0.92) → shaft input ≈ 380–390 kW

Recommended drive:400 kW (≈535 HP)​ electric motor with:

  • Adequate starting torque for 400 bar peak conditions

  • S1 continuous duty rating

  • Speed matching the pump's optimal range (avoid prolonged operation below 750 rpm)


Q7: Can standard NBR seals handle HFC (Water Glycol) or HFD (Phosphate Ester)?

A:

  • HFC (Water Glycol):​ NBR is acceptable but requires:

    • Pressure/temperature derating per Rexroth guidelines (typically pressure × 0.8, Tmax limit +5 °C)

    • Reduced lubricity of HFC → shorter oil change intervals

  • HFD (Phosphate Ester):​ NBR will swell and degrade rapidly → FKM (Viton) seals are mandatory​ (specify /V suffix or FKM option when ordering)

  • Mineral oil (HL/HLP)​ is the standard intended fluid for this model — no special measures needed.


Q8: What are the essential commissioning steps?

A:

  1. Fill and vent:​ Loosen case drain fitting and high-pressure port bleed screw. Manually rotate shaft while filling until oil emerges without bubbles.

  2. Confirm case drain return:​ Verify drain line is connected to tank and unobstructed.

  3. Jog for rotation check:​ Briefly energize motor to confirm CCW (L) rotation. Listen for abnormal noise.

  4. Low-pressure run-in:​ Back off DR adjustment screw (reduce pressure setting). Run at low pressure while cycling system to purge air.

  5. Gradual pressurization:​ Slowly turn DR screw clockwise to raise pressure to target. Monitor noise, temperature, and case drain flow.

  6. Lock and record:​ Once set, tighten lock nut and record the pressure setting for future reference.


如需继续整理其他 Rexroth 型号(A10VSO,A4VG,A11VO,A2FM马达,比例阀,放大器,阀块总成),直接发完整型号即可 👍

연락처 세부 사항
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

담당자: Mr. liyun

전화 번호: +8615280488899

회사에 직접 문의 보내기 (0 / 3000)