Ürün ayrıntıları:
|
| Yaklaşık ağırlık.): | 7,9 kilo | Maks. Akış Hızı (Qmax): | yaklaşık. 500 L/dak (Boyut 20 DB/DBW serisi) |
|---|---|---|---|
| Pilot Yağı: | Dahili pilot beslemesi, dahili pilot tahliyesi (standart DBW) | Solenoid Tipi: | Islak pinli DC solenoidi |
| Solenoid Gerilimi: | 24 VDC (G24) |
|
Parameter |
Value |
|---|---|
|
Part Number |
R900939736 |
|
Model |
DBW 20 - A1 - 5X / 315 - 6EG24N9K4 |
|
Valve Type |
Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
|
Nominal Size (NG) |
20 — subplate mounting per ISO 6264 / NG20 |
|
Function |
Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
|
Adjustment Type |
A1 = Hexagon socket setscrew with protective cap (Allen key adjustable) |
|
Component Series |
5X (series 50–59, dimensionally interchangeable) |
|
Max. Adjustable Relief Pressure |
315 bar (adjustment range typically 4–315 bar) |
|
Max. Operating Pressure (P-port) |
350 bar |
|
Max. Flow Rate (Qmax) |
approx. 500 L/min (Size 20 DB/DBW series) |
|
Pilot Oil |
Internal pilot supply, internal pilot drain (standard DBW) |
|
Solenoid Type |
Wet-pin DC solenoid |
|
Solenoid Voltage |
24 V DC (G24) |
|
Electrical Connection |
Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
|
Manual Override |
N9 = concealed push-button manual override on coil |
|
Seal Material |
NBR (standard, for mineral oil HL/HLP, HFC) |
|
Hydraulic Fluid |
Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
|
Fluid Temperature Range |
-30 °C to +80 °C (NBR seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
7.9 kg |
|
Body Material |
Cast iron / steel, zinc-plated |
![]()
| R901382370 4WRPEH6C5B24L-3X/M/24A1 |
| R901382371 4WRPEH6CB12L-3X/M/24F1 |
| R901382372 4WRPEH6CB24L-3X/M/24F1 |
| R901382374 4WRPEH6CB04L-3X/M/24F1 |
| R901382375 4WRPEH6CB40P-3X/M/24F1 |
| R901382376 4WRPEH6CB02L-3X/M/24F1 |
| R901382487 4WRPEH6C1B40L-3X/M/24F1 |
| R901382488 4WRPEH6C3B04L-3X/V/24A1 |
| R901382489 4WRPEH6C6B02L-3X/M/24A1 |
| R901382490 4WRPEH6CB25P-3X/M/24A1 |
| R901382491 4WRPEH6C1B24L-3X/M/24F1 |
| R901382492 4WRPEH6CB04P-3X/M/24A1 |
| R901382493 4WRPEH6C4B40L-3X/V/24A1 |
| R901382495 4WRPEH6C1B40P-3X/M/24A1 |
| R901382496 4WRPEH6C3B04P-3X/V/24A1 |
| R901382502 4WRPEH6C3B04P-3X/M/24F1 |
| R901382503 4WRPEH6C3B12L-3X/V/24A1 |
| R901382504 4WRPEH6C3B08L-3X/V/24F1 |
| R901382505 4WRPEH6CB04L-3X/V/24F1 |
| R901382509 4WRPEH6C4B40L-3X/V/24F1 |
| R901382510 4WRPEH6C5B24L-3X/M/24F1 |
| R901382511 4WRPEH6C3B15P-3X/M/24F1 |
| R901382512 4WRPEH6C4B40P-3X/M/24F1 |
| R901382513 4WRPEH6C3B12L-3X/V/24F1 |
| R901382514 4WRPEH6C3B04L-3X/V/24F1 |
| R901382515 4WRPEH6C5B04L-3X/M/24F1 |
| R901382516 4WRPEH6C3B40L-3X/V/24F1 |
| R901382517 4WRPEH6C5B12L-3X/M/24F1 |
| R901382519 4WRPEH6C5B12L-3X/M/24A1 |
| R901382520 4WRPEH6CB02L-3X/M/24A1 |
| R901382521 4WRPEH6C4B15P-3X/M/24F1 |
| R901382522 4WRPEH6C3B15P-3X/V/24A1 |
| R901382523 4WRPEH6C4B24L-3X/V/24F1 |
| R901382524 4WRPEH6C5B04L-3X/M/24A1 |
| R901382525 4WRPEH6C4B02L-3X/V/24F1 |
| R901382526 4WRPEH6CB24L-3X/V/24F1 |
| R901382527 4WRPEH6C1B24L-3X/M/24A1 |
| R901382528 4WRPEH6C4B04L-3X/V/24F1 |
| R901382530 4WRPEH6CB15P-3X/M/24A1 |
| R901382532 4WRPEH6C4B25P-3X/M/24F1 |
| R901382533 4WRPEH6C4B04P-3X/M/24A1 |
| R901382534 4WRPEH6C5B40L-3X/V/24F1 |
| R901382535 4WRPEH6C3B25P-3X/M/24F1 |
| R901382537 4WRPEH6C3B04P-3X/V/24F1 |
| R901382538 4WRPEH6C1B12L-3X/M/24A1 |
| R901382539 4WRPEH6C3B40P-3X/M/24F1 |
| R901382630 4WRPEH6CB40P-3X/M/24A1 |
| R901383468 4WRPEH6C4B12L-2X/G24K0/F1V |
| R901387787 4WRPEH6CB04L-2X/G24K0/C6V |
| R901387788 4WRPEH6C4B40L-2X/G24K0/C6V |
| R901396859 4WRPEH6C3B08L-3X/M/24A1 |
| R901396969 4WRPEH6C3B04L-3X/M/24F1-885 |
| R901402614 4WRPEH6C3B24L-3X/G24K0/A1M=KM |
| R901402817 4WRPEH6C3B24L-2X/G24K0/A1M=KM |
| R901408241 4WRPEH6C5B24L-3X/V/24A1 |
| R901409296 4WRPEH6C3B02L-2X/G24K0/A1M-816=KM |
| R901410492 4WRPEH6C3B40L-3X/M/24A1-15 |
| R901412522 4WRPEH6C4B12L-3X/M/24A1-561 |
Q1: What is the difference between DB and DBW?
DB is a pilot relief valve only — limits system pressure. DBW adds an integrated directional solenoid valve: when energized the main stage is unloaded (P→T open, near 0 bar); when de-energized it works as a normal relief valve at the set pressure.
Q2: How is Size 20 (NG20) different from Size 10 (NG10)?
Flow: NG20 handles approx. 500 L/min vs ~250 L/min for NG10.
Mounting: NG20 uses four M12 bolts (tor70–80 N·m) on an NG20 subplate (G 3/4" or M27×2 ports); NG10 uses M10 bolts on NG10 subplate.
Pressure stages & solenoid specs are identical.
Q3: How do I adjust the relief pressure?
With system depressurized, remove the protective cap, turn the setscrew with an Allen key — clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Reinstall cap and verify with a pressure gauge. The solenoid does NOT change the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T). Confirm this matches your PLC/control logic before wiring.
Q5: Which subplate and electrical connector are needed?
Subplate: standard NG20 (ISO 6264) with P and T ports (G 3/4" BSP or M27×2 on subplate), four M12 bolts @ ~70–80 N·m.
Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (–) polarity markings.
Q6: Common faults & causes?
Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18–28 Ω), manual override jammed.
Pressure won't reach set value / creeps early: wrong spring (not /315), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted — replace only with correct G24 wet-pin coil.
Chatter / unstable: air in system, high T-backpressure, worn pilot seat — bleed air first.
Q7: Does T-port backpressure affect set pressure?
Yes — this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.