logo
Home ProductsRexroth Hydraulic Valve

R983030726 4WMM6D6X/ Rexroth manual directional valve

I'm Online Chat Now

R983030726 4WMM6D6X/ Rexroth manual directional valve

R983030726  4WMM6D6X/ Rexroth manual directional valve
R983030726  4WMM6D6X/ Rexroth manual directional valve

Large Image :  R983030726 4WMM6D6X/ Rexroth manual directional valve

Product Details:
Place of Origin: Germany
Brand Name: Rexroth
Certification: ISO
Model Number: R983030726 4WMM6D6X/
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

R983030726 4WMM6D6X/ Rexroth manual directional valve

Description
Weight​: Approx. 1.4 Kg Hydraulic Fluid​: Mineral Oils (HL, HLP), HFC, HFD, HETG, HEES
Viscosity Range​: 2.8 - 500 Mm²/s (Optimal: 20 - 100 Mm²/s) Fluid Cleanliness​: ISO 4406 Class 20/18/15 (Recommended: Cleaner)
Manufacturer Part No.​: R983030726
Highlight:

Rexroth manual directional hydraulic valve

,

Rexroth hydraulic valve with warranty

,

4WMM6D6X hydraulic directional valve

Parameter

Specification

Manufacturer Part No.

R983030726

Valve Type

Manual Directional Spool Valve (Direct-Acting)

Series / Platform

WMM Series, Size NG6, Component Series 6X

Spool Type

D-Type​ (Specific center position flow pattern, e.g., O, M, H, etc.)

Max. Operating Pressure

315 bar​ (Ports P, A, B)
160 bar​ (Port T - Return)

Max. Flow Rate

60 L/min​ (Recommended for standard pressure drop)

Port Connection

NG6 Interface (ISO 4401-03-02-0-05 / CETOP 03)

Mounting

Subplate Mounting (Base plate ordered separately)

Actuation

Manual Lever (Spring-Centered or Detent versions exist)

Sealing Material

NBR (Standard for mineral oils)

Weight

Approx. 1.4 kg

Hydraulic Fluid

Mineral oils (HL, HLP), HFC, HFD, HETG, HEES

Viscosity Range

2.8 - 500 mm²/s (Optimal: 20 - 100 mm²/s)

Fluid Cleanliness

ISO 4406 Class 20/18/15 (Recommended: Cleaner)

R983030726  4WMM6D6X/ Rexroth manual directional valve 0

R900722193  4WEH10Q4X/6EG24N9ETK4/10B08  
R901114321  4WEH10Q4X/6EG24N9ETSK4/B10V  
R901209683  4WEH10Q4X/6EG24N9ETSK4/B10D3  
R901210809  4WEH10Q4X/6EG24N9ETS2K4/B10  
R901209817  4WEH10Q4X/6EG24N9ETS2K4/B10D3  
R900710131  4WEH10Q4X/6EG24N9ETS2K4/10B10  
R900911418  4WEH10Q4X/6EG24N9TK4  
R900967615  4WEH10Q4X/6EG24N9TSK4  
R900974486  4WEH10R4X/6EG24NETS2K4/B10  
R900947420  4WEH10R4X/6EG24N9K4  
R900617194  4WEH10R4X/6EG24N9K4/B08  
R901005904  4WEH10R4X/6EG24N9K4/10  
R901075408  4WEH10R4X/6EG24N9K4/10B10  
R901087314  4WEH10R4X/6EG24N9SK4  
R901161155  4WEH10R4X/6EG24N9S2K4  
R900969433  4WEH10R4X/6EG24N9EK4/B08  
R901003849  4WEH10R4X/6EG24N9EK4/B10  
R901178522  4WEH10R4X/6EG24N9ESK4/B10  
R900785212  4WEH10R4X/6EG24N9ES2K4/B10  
R900755366  4WEH10R4X/6EG24N9ETK4/B08  
R901045616  4WEH10R4X/6EG24N9ETK4/B10  
R901235479  4WEH10R4X/6EG24N9ETK4/B10D3  
R900727510  4WEH10R4X/6EG24N9ETK4/10B10  
R900711924  4WEH10R4X/6EG24N9ETSK4QM0G24/B10  
R901210821  4WEH10R4X/6EG24N9ETS2K4/B10  
R900743749  4WEH10R4X/6EG24N9ETS2K4/10B10  
R900608679  4WEH10R4X/6EG24N9TK4  
R900962438  4WEH10R4X/6EG24N9TK4/10B08  
R900705288  4WEH10R4X/6EG24N9TK4QM0G24  
R901138039  4WEH10R4X/6EW230N9ES2K4/B10  
R901210822  4WEH10R4X/6EW230N9ETK4/B10  
R901025375  4WEH10R4X/6EW230N9ETS2K4/B10  
R900976345  4WEH10R4X/6EW230N9TSK4  
R901002920  4WEH10R4X/6EW230N9TS2K4  
R900961293  4WEH10RB4X/6EG24N9K4  
R900956206  4WEH10RB4X/6EG24N9K4/B08  
R901016076  4WEH10RB4X/6EG24N9ETK4/11B10  
R900734245  4WEH10RB4X/6EG24N9ETS2K4/B10  
R900973914  4WEH10RB4X/6EW230N9ETK4/B10V  
R900750223  4WEH10T4X/6EG24K4QM0G24  
R900779385  4WEH10T4X/6EG24K4QM0G24/B10D3  
R901211865  4WEH10T4X/6EG24ETK4QM0G24/B10  
R900977227  4WEH10T4X/6EG24N9K4  
R901233070  4WEH10T4X/6EG24N9ETK4/B10  
R901114087  4WEH10T4X/6EG24N9ETK4QMABG24/B10  
R900966929  4WEH10T4X/6EG24N9ETK4QM0G24/B10  
R900247760  4WEH10T4X/6EW230N9EK4/B10D3  
R901089032  4WEH10TB4X/6EG24N9TS2K4/B10  
R901087120  4WEH10TB4X/6EG24N9TS2K4/10  
R900617173  4WEH10U4X/6EG24N9K4  
R901225121  4WEH10U4X/6EG24N9K4/B10  
R900947453  4WEH10U4X/6EG24N9K4QM0G24  
R901023717  4WEH10U4X/6EG24N9EK4/B10  
R900956611  4WEH10U4X/6EG24N9ETK4/B10  
R900978783  4WEH10U4X/6EG24N9ETS2K4/B10  
R900702670  4WEH10U4X/6EG24N9TK4  


Frequently Asked Questions (FAQ)

1. Basic Parameters & Selection

Q: What is the function of this valve?

A: This is a manual directional control valve. It is used to start, stop, and change the direction of fluid flow in a hydraulic system by manually operating a lever. The "D" in the model number indicates a specific spool type (e.g., O, M, H, etc.), which defines the internal flow path in the center position.

Q: What does "4WMM6D6X" mean?

A:

  • 4WM: Directional valve series.

  • M: Manual operation.

  • 6: NG6 size (CETOP 03).

  • D: Spool type code​ (defines the center position flow pattern).

  • 6X: Component series.

Q: What is the difference between this and an electromagnetic valve?

A: This valve is operated by a manual lever​ and does not require electrical power. It is typically used for testing, emergency operation, or in systems where electrical control is not desired.

2. Installation & Commissioning

Q: How is this valve mounted?

A: It is a subplate-mounted valve. It requires a separate base plate (e.g., according to ISO 4401-03-02-0-05) that is screwed onto the manifold or tank. The valve then mounts onto this base plate.

Q: What are the critical installation warnings?

A:

  • Port T Pressure:​ The return port (T) has a lower pressure rating (160 bar) than the P, A, B ports. Ensure your system's backpressure does not exceed this limit.

  • Cleanliness:​ The valve contains precision spools. Install it only in a clean environment and flush the system thoroughly before commissioning.

  • Mounting Torque:​ Use the correct torque (typically 12-15 Nm for M6 screws) to avoid warping the subplate.

Q: How do I connect the ports?

A: The standard port configuration is:

  • P: Pressure In (from pump)

  • T: Tank Return

  • A, B: Work ports (to cylinder or motor)

3. Operation & Troubleshooting

Q: The lever is very hard to operate. What is wrong?

A: High operating force is usually due to:

  1. High System Pressure:​ The spool is under pressure, creating a hydraulic lock. Operate the lever only when the system pressure is low or relieved.

  2. Contamination:​ Dirt or varnish inside the valve can cause the spool to stick. Check the oil cleanliness.

Q: The cylinder drifts or does not hold position in the center position.

A: This is typically not a valve failure​ but a function of the spool type (D). Some spool types (like H-type) allow flow in the center position, causing the cylinder to drift. Check the spool's center position diagram. If it is supposed to be closed (O-type) and still drifts, check for worn spool seals or a damaged cylinder.

Q: There is external leakage from the shaft or mounting area.

A: This indicates worn shaft seals or a damaged O-ring between the valve and the subplate. The valve requires disassembly and resealing.

4. Maintenance

Q: What type of oil and cleanliness are required?

A: Use ISO VG 32/46/68 mineral-based oils (HL, HLP). The oil cleanliness must be NAS Class 9 or cleaner​ (ISO 4406 18/16/13) for long service life. Contamination is the primary cause of spool sticking and wear.

Q: Can I repair this valve myself?

A: Limited repair is possible.​ Seal kits are available for replacing external O-rings and shaft seals. However, repairing or lapping the internal spool and body requires specialized equipment. For critical applications, replacing the valve is often more reliable.

Q: What is the expected service life?

A: Under correct conditions (clean oil, within pressure ratings), the mechanical life can be several million cycles. The primary failure modes are seal wear​ and spool sticking due to contamination.

Disclaimer:​ This data is based on standard Rexroth WMM series documentation. The exact center position flow pattern (O, M, H, etc.) is defined by the "D" code, which should be verified with the supplier's datasheet. Always refer to the official technical data for your specific application and safety guidelines.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)