Produktdetails:
|
| Gewicht.: | ca. 1,4 kg | Hydraulikflüssigkeit: | Mineralöle (HL, HLP), HFC, HFD, HETG, HEES |
|---|---|---|---|
| Viskositätsbereich: | 2,8 - 500 mm²/s (Optimal: 20 - 100 mm²/s) | Flüssigkeitsreinheit: | ISO 4406 Klasse 20/18/15 (Empfohlen: Reiniger) |
| Hersteller-Teilenummer.: | R983030726 | ||
| Hervorheben: | Rexroth manual directional hydraulic valve,Rexroth hydraulic valve with warranty,4WMM6D6X hydraulic directional valve |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer Part No. |
R983030726 |
|
Valve Type |
Manual Directional Spool Valve (Direct-Acting) |
|
Series / Platform |
WMM Series, Size NG6, Component Series 6X |
|
Spool Type |
D-Type (Specific center position flow pattern, e.g., O, M, H, etc.) |
|
Max. Operating Pressure |
315 bar (Ports P, A, B) |
|
Max. Flow Rate |
60 L/min (Recommended for standard pressure drop) |
|
Port Connection |
NG6 Interface (ISO 4401-03-02-0-05 / CETOP 03) |
|
Mounting |
Subplate Mounting (Base plate ordered separately) |
|
Actuation |
Manual Lever (Spring-Centered or Detent versions exist) |
|
Sealing Material |
NBR (Standard for mineral oils) |
|
Weight |
Approx. 1.4 kg |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HFC, HFD, HETG, HEES |
|
Viscosity Range |
2.8 - 500 mm²/s (Optimal: 20 - 100 mm²/s) |
|
Fluid Cleanliness |
ISO 4406 Class 20/18/15 (Recommended: Cleaner) |
![]()
| R900722193 4WEH10Q4X/6EG24N9ETK4/10B08 |
| R901114321 4WEH10Q4X/6EG24N9ETSK4/B10V |
| R901209683 4WEH10Q4X/6EG24N9ETSK4/B10D3 |
| R901210809 4WEH10Q4X/6EG24N9ETS2K4/B10 |
| R901209817 4WEH10Q4X/6EG24N9ETS2K4/B10D3 |
| R900710131 4WEH10Q4X/6EG24N9ETS2K4/10B10 |
| R900911418 4WEH10Q4X/6EG24N9TK4 |
| R900967615 4WEH10Q4X/6EG24N9TSK4 |
| R900974486 4WEH10R4X/6EG24NETS2K4/B10 |
| R900947420 4WEH10R4X/6EG24N9K4 |
| R900617194 4WEH10R4X/6EG24N9K4/B08 |
| R901005904 4WEH10R4X/6EG24N9K4/10 |
| R901075408 4WEH10R4X/6EG24N9K4/10B10 |
| R901087314 4WEH10R4X/6EG24N9SK4 |
| R901161155 4WEH10R4X/6EG24N9S2K4 |
| R900969433 4WEH10R4X/6EG24N9EK4/B08 |
| R901003849 4WEH10R4X/6EG24N9EK4/B10 |
| R901178522 4WEH10R4X/6EG24N9ESK4/B10 |
| R900785212 4WEH10R4X/6EG24N9ES2K4/B10 |
| R900755366 4WEH10R4X/6EG24N9ETK4/B08 |
| R901045616 4WEH10R4X/6EG24N9ETK4/B10 |
| R901235479 4WEH10R4X/6EG24N9ETK4/B10D3 |
| R900727510 4WEH10R4X/6EG24N9ETK4/10B10 |
| R900711924 4WEH10R4X/6EG24N9ETSK4QM0G24/B10 |
| R901210821 4WEH10R4X/6EG24N9ETS2K4/B10 |
| R900743749 4WEH10R4X/6EG24N9ETS2K4/10B10 |
| R900608679 4WEH10R4X/6EG24N9TK4 |
| R900962438 4WEH10R4X/6EG24N9TK4/10B08 |
| R900705288 4WEH10R4X/6EG24N9TK4QM0G24 |
| R901138039 4WEH10R4X/6EW230N9ES2K4/B10 |
| R901210822 4WEH10R4X/6EW230N9ETK4/B10 |
| R901025375 4WEH10R4X/6EW230N9ETS2K4/B10 |
| R900976345 4WEH10R4X/6EW230N9TSK4 |
| R901002920 4WEH10R4X/6EW230N9TS2K4 |
| R900961293 4WEH10RB4X/6EG24N9K4 |
| R900956206 4WEH10RB4X/6EG24N9K4/B08 |
| R901016076 4WEH10RB4X/6EG24N9ETK4/11B10 |
| R900734245 4WEH10RB4X/6EG24N9ETS2K4/B10 |
| R900973914 4WEH10RB4X/6EW230N9ETK4/B10V |
| R900750223 4WEH10T4X/6EG24K4QM0G24 |
| R900779385 4WEH10T4X/6EG24K4QM0G24/B10D3 |
| R901211865 4WEH10T4X/6EG24ETK4QM0G24/B10 |
| R900977227 4WEH10T4X/6EG24N9K4 |
| R901233070 4WEH10T4X/6EG24N9ETK4/B10 |
| R901114087 4WEH10T4X/6EG24N9ETK4QMABG24/B10 |
| R900966929 4WEH10T4X/6EG24N9ETK4QM0G24/B10 |
| R900247760 4WEH10T4X/6EW230N9EK4/B10D3 |
| R901089032 4WEH10TB4X/6EG24N9TS2K4/B10 |
| R901087120 4WEH10TB4X/6EG24N9TS2K4/10 |
| R900617173 4WEH10U4X/6EG24N9K4 |
| R901225121 4WEH10U4X/6EG24N9K4/B10 |
| R900947453 4WEH10U4X/6EG24N9K4QM0G24 |
| R901023717 4WEH10U4X/6EG24N9EK4/B10 |
| R900956611 4WEH10U4X/6EG24N9ETK4/B10 |
| R900978783 4WEH10U4X/6EG24N9ETS2K4/B10 |
| R900702670 4WEH10U4X/6EG24N9TK4 |
Q: What is the function of this valve?
A: This is a manual directional control valve. It is used to start, stop, and change the direction of fluid flow in a hydraulic system by manually operating a lever. The "D" in the model number indicates a specific spool type (e.g., O, M, H, etc.), which defines the internal flow path in the center position.
Q: What does "4WMM6D6X" mean?
A:
4WM: Directional valve series.
M: Manual operation.
6: NG6 size (CETOP 03).
D: Spool type code (defines the center position flow pattern).
6X: Component series.
Q: What is the difference between this and an electromagnetic valve?
A: This valve is operated by a manual lever and does not require electrical power. It is typically used for testing, emergency operation, or in systems where electrical control is not desired.
Q: How is this valve mounted?
A: It is a subplate-mounted valve. It requires a separate base plate (e.g., according to ISO 4401-03-02-0-05) that is screwed onto the manifold or tank. The valve then mounts onto this base plate.
Q: What are the critical installation warnings?
A:
Port T Pressure: The return port (T) has a lower pressure rating (160 bar) than the P, A, B ports. Ensure your system's backpressure does not exceed this limit.
Cleanliness: The valve contains precision spools. Install it only in a clean environment and flush the system thoroughly before commissioning.
Mounting Torque: Use the correct torque (typically 12-15 Nm for M6 screws) to avoid warping the subplate.
Q: How do I connect the ports?
A: The standard port configuration is:
P: Pressure In (from pump)
T: Tank Return
A, B: Work ports (to cylinder or motor)
Q: The lever is very hard to operate. What is wrong?
A: High operating force is usually due to:
High System Pressure: The spool is under pressure, creating a hydraulic lock. Operate the lever only when the system pressure is low or relieved.
Contamination: Dirt or varnish inside the valve can cause the spool to stick. Check the oil cleanliness.
Q: The cylinder drifts or does not hold position in the center position.
A: This is typically not a valve failure but a function of the spool type (D). Some spool types (like H-type) allow flow in the center position, causing the cylinder to drift. Check the spool's center position diagram. If it is supposed to be closed (O-type) and still drifts, check for worn spool seals or a damaged cylinder.
Q: There is external leakage from the shaft or mounting area.
A: This indicates worn shaft seals or a damaged O-ring between the valve and the subplate. The valve requires disassembly and resealing.
Q: What type of oil and cleanliness are required?
A: Use ISO VG 32/46/68 mineral-based oils (HL, HLP). The oil cleanliness must be NAS Class 9 or cleaner (ISO 4406 18/16/13) for long service life. Contamination is the primary cause of spool sticking and wear.
Q: Can I repair this valve myself?
A: Limited repair is possible. Seal kits are available for replacing external O-rings and shaft seals. However, repairing or lapping the internal spool and body requires specialized equipment. For critical applications, replacing the valve is often more reliable.
Q: What is the expected service life?
A: Under correct conditions (clean oil, within pressure ratings), the mechanical life can be several million cycles. The primary failure modes are seal wear and spool sticking due to contamination.
Disclaimer: This data is based on standard Rexroth WMM series documentation. The exact center position flow pattern (O, M, H, etc.) is defined by the "D" code, which should be verified with the supplier's datasheet. Always refer to the official technical data for your specific application and safety guidelines.