Fluid Compatibility:Mineral oil (HLP), synthetic oil (HETG/HEES)
What types of hydraulic fluids are compatible with the PV7 series?:Mineral oil (HLP) and synthetic oil (HETG/HEES); use FKM seals for synthetic fluids
Viscosity Range:10–1000 mm²/s (operation); 2–1500 mm²/s (start-up)
Shaft Connection:Viton® or NBR shaft seals (resistant to high temperature and oil)
Mounting Type:Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Suction Pressure:Flange mounting (ISO 3019-2 standard), foot mounting (optional)
Model Range:PV7-1X/10-14RE01MN0-16 PV7-1X/40-45RE37MC5-16 PV7-1X/100-118RE07MC5-16 Rexroth spot original
Max. Continuous Working Pressure:100
Fluid Viscosity Range:10–1000 (operation); 2–1500 (start-up)
Shaft Connection:Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Total Efficiency:≥80% (at rated working condition)
Fluid Temperature Range:'-20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range:10–1000 mm²/s (operation); 2–1500 mm²/s (start-up)
Fluid Temperature Range:'-20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Displacement per Revolution:10–25 cm³/rev (varies by specific model)
Parameter:Specification
Model Series:PV7-1X/40-45RE37MW6-16WH PV7-1X/100-118RE07MD6-16 PV7-1X/40-45RE37MC5-16WG (typical models)
Displacement per Revolution:10–25 cm³/rev (varies by specific model)
Feature:Details
Mounting Type:Flange mounting (ISO 3019-2 standard), foot mounting (optional)
Shaft Connection:Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Viscosity Range:10–1000 mm²/s (operation); 2–1500 mm²/s (start-up)
Fluid Temperature Range:'-20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Model Series:PV7-1X/06-10RA01MA0-10-P65Q12 PV7-2X/20-25RA01MA0-10-P63Q35 PV7-1X/06-10RA01MA0-10-P70Q12
What types of hydraulic fluids are compatible with the PV7 series?:Mineral oil (HLP) and synthetic oil (HETG/HEES); use FKM seals for synthetic fluids
What is the fluid viscosity range for PV7 series operation?:10–1000 mm²/s (operation); 2–1500 mm²/s (start-up); optimal range is 16–160 mm²/s
What is the fluid temperature range for PV7 series operation?:-20 to +80 °C (operation); -40 to +90 °C (storage)
Speed Range:600–2800
Mounting Standard:ISO 3019-2 flange
Minimum Speed:600 rpm (ensures stable operation)
What does "1X/2X" represent in the PV7 model code?:It indicates the component series of the pump
What is the displacement per revolution range of the direct-acting PV7 series?:10–25 cm³/rev
What type of shaft connection does the PV7 series use?:ISO 4162 splined shaft; keyed shaft available on request
Model Series:PV7-1X/06-10RA01MA0-05-P15Q08 PV7-1X/06-14RA01MA0-07-P70Q18 PV7-1X/06-10RA01MA0-05-P25Q09
Displacement per Revolution:10–25 cm³/rev (varies by specific model)
Maximum Speed:1800–3600 rpm (depends on displacement and fluid viscosity)