제품 상세 정보:
|
| (대략적인 중량.): | 3.22 킬로그램 | 점도 범위: | 10~800mm²/초 |
|---|---|---|---|
| 수압 액체: | DIN 51524에 따른 미네랄 오일 HL, HLP; HFC(물-글리콜); HLPD, HVLP, HVLPD | 씰 재질: | NBR(표준, 광유 HL/HLP, HFC용) |
| 솔레노이드 전압: | 24V DC(G24) |
|
Parameter |
Value |
|---|---|
|
Part Number |
R900925192 |
|
Model |
DBW 10 - B2 - 5X / 350 - 6EG24N9K4 |
|
Valve Type |
Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
|
Nominal Size (NG) |
10 — subplate mounting per ISO 6264 / NG10 |
|
Function |
Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
|
Adjustment Type |
B2 = Rotary hand knob with protective cap (hand-adjustable, no tool; B-version has different pilot damping orifice vs A-version) |
|
Component Series |
5X (series 50–59, dimensionally interchangeable) |
|
Max. Adjustable Relief Pressure |
350 bar (adjustment range typically 5–350 bar) |
|
Max. Operating Pressure (P-port) |
350 bar |
|
Max. Flow Rate (Qmax) |
approx. 250 L/min (Size 10 DB/DBW series) |
|
Pilot Oil |
Internal pilot supply, internal pilot drain (standard DBW) |
|
Solenoid Type |
Wet-pin DC solenoid |
|
Solenoid Voltage |
24 V DC (G24) |
|
Electrical Connection |
Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
|
Manual Override |
N9 = concealed push-button manual override on coil |
|
Seal Material |
NBR (standard, for mineral oil HL/HLP, HFC) |
|
Hydraulic Fluid |
Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
|
Fluid Temperature Range |
-30 °C to +80 °C (NBR seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
3.22 kg |
|
Body Material |
Cast iron / steel, zinc-plated |
![]()
| R900715040 4WRKE16W8-200L-3X/6EG24ETK31/F1D3M |
| R900731881 4WRKE25W8-350L-3X/6EG24ETK31/A1D3M |
| R900743953 4WRKE25W8-350L-3X/6EG24ETK31/F1D3M |
| R901502770 4WRDE16W8-150L-6X/MXY/24A5 |
| R901520296 4WRDE25V1-350L-6X/MXYWG/24A5 |
| R901401731 4WRLE25V370M-4X/MXY/24A1 |
| 0811404033 4WRPH6C3B04L-2X/G24Z4/M |
| 0811404035 4WRPH6C3B24L-2X/G24Z4/M |
| 0811404038 4WRPH6C4B24L-2X/G24Z4/M |
| R901382315 4WRPEH6C3B40L-3X/M/24A1 |
| R901382318 4WRPEH6C4B12L-3X/M/24A1 |
| R901382346 4WRPEH6C4B24L-3X/M/24A1 |
| R901382350 4WRPEH6C3B40L-3X/M/24F1 |
| R901382369 4WRPEH6C5B40L-3X/M/24F1 |
| 0811404059 4WRPH10C3B100L-2X/G24Z4/M |
| 0811404061 4WRPH10C4B100L-2X/G24Z4/M |
| 0811404800 4WRPEH10C3B50L-2X/G24K0/A1M |
| 0811404803 4WRPEH10C4B100L-2X/G24K0/A1M |
| 0811404817 4WRPEH10C3B100L-2X/G24K0/F1M |
| R901493886 4WRPEH10C3B100L-3X/M/24A1 |
| R901411433 4WRPEH10C4B100L-3X/M/24A1 |
| R901507310 4WRPEH10C3B100L-3X/M/24F1 |
| 0811404902 4WRPH10C3B100L-2X/G24K0/M-750 |
| 0811404818 4WRPE10CB80M-2X/G24K0/A1M-846 |
| 0811404766 4WRPE10CB80L-2X/G24K0/F1M-810 |
| 0811404094 4WRL10V85M-3X/G24Z4/M |
| 0811404207 4WRL16V200M-3X/G24Z4/M |
| 0811404405 4WRL25V370M-3X/G24Z4/M |
| R901000846 DBET-6X/200G24K4V |
| R901170278 DBET-6X/200G24-8K4V |
| R901000847 DBET-6X/315G24K4V |
| R901000848 DBET-6X/350G24K4V |
| 0811402044 DBE6X-1X/180G24-8NZ4M |
| R901304402 DBE6-2X/315YG24K4/M |
| R901029967 DBETE-6X/100G24K31/A1V |
| R901029968 DBETE-6X/200G24K31/A1V |
| R901029969 DBETE-6X/315G24K31/A1V |
| R901064278 DBETE-6X/315YG24K31A1V |
| R901045246 DBETE-6X/315G24K31/F1V |
| R901119906 DBETE-6X/315YG24K31/F1V |
| R901029970 DBETE-6X/350G24K31/A1V |
| R901363311 DBEME30-7X/200YG24K31A1V |
| R900932943 DRE6-1X/100MG24K4M |
| R900928873 DRE6-1X/21OMG24K4M |
| 0811402055 DRE6X-1X/175MG24-8NZ4M |
| 0811402080 DREBE6X-1X/175MG24K31A1M |
| 0811402083 DREBE6X-1X/175MG24K31F1M |
| 0811402081 DREBE6X-1X/310MG24K31A1M |
| R901272516 DREE10-6X/200YMG24K31A1M |
| R901278156 DREE10-6X/200YG24K31F1M |
| R901289456 DREME10-6X/315YMG24K31A1M |
| R901275714 DREE20-6X/200YMG24K31A1M |
| R901278310 DREE20-6X/315YMG24K31A1M |
| R901325506 DREME20-6X/315YG24K31A1M |
| R901428941 DREME20-6X/315YMG24K31F1M |
| R901483246 Z3DREE10VP2-1X/200XLG24K31A1M |
| R901483247 Z3DREE10VP2-1X/315XLG24K31A1M |
Q1: What is the difference between A-version and B-version (DBW10A2 vs DBW10B2)?
Both are pilot-operated relief valves with solenoid unload and identical pressure/flow/solenoid specs. The B-version has a different pilot damping orifice which changes dynamic response (pressure overshoot, settling time). A-version is the general-purpose default; B-version is selected when system-specific stability tuning is needed. Externally both A2 and B2 have the same rotary hand knob adjustment.
Q2: Is this direct-acting or pilot-operated?
It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.
Q3: How do I adjust the relief pressure?
With system depressurized, lift/remove the protective cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Replace the cap after setting and verify with a pressure gauge. The solenoid does NOT alter the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.
Q5: Which subplate and electrical connector are needed?
Subplate: standard NG10 (ISO 6264) with P and T ports (G 1/2" or M18×1.5 on subplate), four M10 bolts @ ~35–40 N·m.
Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (–) polarity markings.
Q6: Common faults & causes?
Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18–28 Ω), manual override jammed.
Pressure won't reach set value / creeps early: wrong spring (not /350), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted, or mechanical damage — replace only with correct G24 wet-pin coil.
Chatter / unstable: air in system, high T-backpressure, worn pilot seat — bleed air first.
Q7: Does T-port backpressure affect set pressure?
Yes — this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).