Detail produk:
|
| Sinyal Perintah: | 4–20 mA (Input analog, setara dengan pembukaan katup 0–100%) | Bahan Segel: | NBR (Standar untuk minyak mineral) |
|---|---|---|---|
| Cairan Hidrolik: | Minyak mineral (HL, HLP), HETG, HEES, HFDU | Suhu Pengoperasian: | -20°C Hingga +60°C |
| Berat: | Kira-kira. 7,4kg | ||
| Menyoroti: | Katup kontrol aliran proporsional Rexroth,katup hidrolik Rexroth dengan garansi,katup kontrol aliran Rexroth Jerman |
||
|
Parameter |
Spesifikasi |
|---|---|
|
Pabrikan / Seri |
Seri Rexroth 2WFCE |
|
Kode Pesanan |
R901430258 |
|
Model Lengkap |
2WFCE40S500L-1X/M/24G1 |
|
Tipe Katup |
Katup Kartrid Arah Proporsional yang Dioperasikan Pilot (2 arah, 2 posisi) |
|
Fungsi Utama |
Pelambatan/kontrol aliran proporsional aliran tinggi; dapat digunakan sebagai katup pengarah. |
|
Tipe Kontrol |
Solenoida proporsional denganElektronik Terintegrasi (OBE)dan umpan balik posisi. |
|
Ukuran Nominal |
NG 40 (Ukuran kartrid per ISO 7368) |
|
Maks. Tekanan Operasi |
420 bar (Port A, B) |
|
Nilai Aliran (Qn) |
500 liter/menit |
|
Karakteristik Aliran |
Linier (Kiri) |
|
Kompensasi Tekanan |
Tidak (Membutuhkan kompensator tekanan eksternal untuk kontrol aliran yang tidak bergantung pada beban). |
|
Pelabuhan |
A, B, X (Pilot), Y (Pembuangan) |
|
Pemasangan |
Sisipan Kartrid (Rongga sesuai ISO 7368) |
|
Sambungan Listrik |
Konektor 12-pin (11+PE) sesuai EN 175201-804 |
|
Tegangan Pasokan |
24 V DC (Elektronik terintegrasi, tidak memerlukan amplifier eksternal) |
|
Sinyal Perintah |
4–20 mA (Input analog, setara dengan pembukaan katup 0–100%) |
|
Bahan Segel |
NBR (Standar untuk minyak mineral) |
|
Cairan Hidraulik |
Minyak mineral (HL, HLP), HETG, HEES, HFDU |
|
Suhu Operasional |
-20°C hingga +60°C |
|
Berat |
Kira-kira. 7,4kg |
|
Negara Asal |
Jerman |
![]()
| R900760386 2FRE10-4X/16LBK4V |
| R900959337 2FRE10-4X/16LK4M |
| R900976050 2FRE10-4X/16LK4V |
| R900245908 2FRE10-4X/16QBK4M |
| R900768728 2FRE10-4X/16QK4M |
| R900915820 2FRE10-4X/25LBK4M |
| R900249888 2FRE10-4X/25LBK4V |
| R900932728 2FRE10-4X/25LK4M |
| R900962961 2FRE10-4X/25QBK4M |
| R900948692 2FRE10-4X/25QK4M |
| R900764820 2FRE10-4X/2QEBK4M |
| R900963481 2FRE10-4X/2QEK4M |
| R900915815 2FRE10-4X/50LBK4M |
| R901021448 2FRE10-4X/50LBK4V |
| R900915813 2FRE10-4X/50LK4M |
| R900244809 2FRE10-4X/50LK4V |
| R900931237 2FRE10-4X/5LBK4M |
| R900942938 2FRE10-4X/5LK4M |
| R900962409 2FRE10-4X/5LK4V |
| R900946937 2FRE10-4X/5QBK4M |
| R900964806 2FRE10-4X/5QEBK4M |
| R900962277 2FRE10-4X/5QEK4M |
| R900915823 2FRE10-4X/60LBK4M |
| R900976616 2FRE10-4X/60LBK4V |
| R900915821 2FRE10-4X/60LK4M |
| R900973066 2FRE10-4X/60LK4V |
| R900915819 2FRE16-4X/100LBK4M |
| R900785982 2FRE16-4X/100LBK4V |
| R900915822 2FRE16-4X/100LK4M |
| R900721995 2FRE16-4X/100LK4V |
| R900927478 2FRE16-4X/125LBK4M |
| R901040916 2FRE16-4X/125LBK4V |
| R900915824 2FRE16-4X/125LK4M |
| R900915814 2FRE16-4X/160LBK4M |
| R900747708 2FRE16-4X/160LBK4V |
| R900915816 2FRE16-4X/160LK4M |
| R900973515 2FRE16-4X/160LK4V |
| R900962297 2FRE16-4X/60LBK4M |
| R900927479 2FRE16-4X/80LBK4M |
| R901070659 2FRE16-4X/80LBK4V |
| R900915818 2FRE16-4X/80LK4M |
| R900734638 2FRE16-4X/80LK4V |
| R900937860 2FRE6A-2X/10QK4MV |
| R900937866 2FRE6A-2X/10QK4RV |
| R900937864 2FRE6A-2X/16QK4MV |
| R900958063 2FRE6A-2X/16QK4RV |
| R900770641 2FRE6A-2X/1LK4MV |
| R900960170 2FRE6A-2X/1LK4RV |
| R900937865 2FRE6A-2X/25QK4MV |
| R900937883 2FRE6A-2X/25QK4RV |
| R900961336 2FRE6A-2X/2LK4MV |
| R900245015 2FRE6A-2X/2LK4RV |
| R900960182 2FRE6A-2X/2QEK4MV |
| R900962992 2FRE6A-2X/2QEK4RV |
| R900950857 2FRE6A-2X/3QK4MV |
| R900937867 2FRE6A-2X/3QK4RV |
| R900973053 2FRE6A-2X/6QK4MV |
| R900956195 2FRE6A-2X/6QK4RV |
| R900967793 2FRE6A-2X/8LK4MV |
| R900975322 2FRE6A-2X/8LK4RV |
Q1: Apa perbedaan utama antara seri 2WFCE dan seri 2FRE?
A: Itu2WFCEadalah akatup bergaya kartrid yang dioperasikan pilotdirancang untuk sangataliran tinggi (500 L/mnt) dan tekanan tinggi (420 bar). Itu dipasang di rongga manifold. Itu2FREadalah akatup yang dipasang di bawah pelat dan dioperasikan langsungBiasanya digunakan untuk aplikasi aliran rendah. 2WFCE juga dilengkapiElektronik Terintegrasi (OBE), artinya amplifier terpasang pada penutup katup.
Q2: Apakah katup ini dilengkapi kompensasi tekanan bawaan?
A:TIDAK.2WFCE40S500L adalah katup pengarah/pelambatan proporsional. Memang benarbukanmemiliki kompensator tekanan bawaan. Untuk mencapaikontrol aliran bebas beban, Anda harus menginstal yang terpisahkompensator tekanan (misalnya, kompensator tekanan tipe FD) di hulu atau hilir katup ini.
Q3: Apa yang ditunjukkan oleh akhiran "24G1"?
A:24G1menentukan antarmuka listrik:
24: Tegangan suplai 24 V DC.
G1: Input perintah analog dari4–20mA (sinyal saat ini). Antarmuka ini juga menyediakan keluaran sinyal "Siap" untuk memantau status elektronik katup.
Q4: Apa yang terjadi jika listrik padam atau kabel putus?
A: Katup tersebut mempunyai aaman dari kegagalan ditutupfungsi. Jika tegangan pasokan gagal atau turun di bawah ambang batas, atau jika kabel solenoid putus, kumparan tahap utama didorong ke tempatnya oleh gaya pegas dan tekanan sistem,menghalangi aliran antara port A dan B.
Q5: Apa tujuan dari port X dan Y?
A:Pelabuhan Xadalahpasokan percontohanpelabuhan. Itu harus terhubung ke sumber minyak bertekanan (seringkali dari port A atau B, atau sumber eksternal) untuk mengoperasikan tahap percontohan.Pelabuhan Yadalahpelabuhan pembuangan untuk oli kontrol pilot dan harus dihubungkan langsung ke tangki dengan tekanan balik minimal.
Kontak Person: Mr. liyun
Tel: +8615280488899