logo
Home ProductsRexroth Hydraulic Pump

A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump

I'm Online Chat Now

A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump

A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump
A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump

Large Image :  A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: A4VSO250LR2/30L-PPB25N00
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump

Description
Oil Cleanliness Requirement​: ISO 4406 18/16/13​ (NAS 1638 Class 8–9) Case Drain​: Two Case Drain Ports — Must Be Routed To Tank < 2 Bar Backpressure
Seal Material​: FKM (Fluoroelastomer / Viton, Standard For Mineral Oil HLP) Displacement (Vg Max)​: 250 Cm³/rev​
Brand / Origin​: Rexroth / Germany

A4VSO250LR2/30L-PPB25N00 Original imported German Rexroth A4VSO250 piston pump
Product Specifications
Model A4VSO250LR2/30L-PPB25N00
Brand / Origin Rexroth / Germany
Type Swashplate-type axial piston variable pump (Open circuit)
Displacement (Vg max) 250 cm³/rev
Control Type LR2 — Hydro-mechanical constant power (horsepower) control, follows a hyperbolic characteristic curve (P×Q = const). Adjustable starting point of power limiting via set screw.
Nominal Pressure 350 bar (35 MPa) Continuous
Peak / Maximum Pressure 400 bar (40 MPa) Intermittent
Maximum Speed (nₘₐₓ) 1500 rpm @ Vg max (Size 250)
Recommended Speed 1000 - 1500 rpm
Theoretical Flow @ 1500 rpm ≈ 375 L/min (Q = n × Vg / 1000)
Rotation Direction L — Counter‑clockwise (viewed from shaft end)
Mounting Flange ISO 3019‑2 / Series 30, 4‑bolt (Code PP)
Through‑drive Yes — PPB indicates through‑drive capable (N00 = no auxiliary pump fitted)
Port Configuration PPB25 — SAE flange side ports (P & T 90° apart), second pressure port B1 opposite B plugged with SAE flange blank
Seal Material FKM (Fluoroelastomer / Viton, standard for mineral oil HLP)
Case Drain Two case drain ports — must be routed to tank < 2 bar backpressure
Recommended Oil Viscosity 16 - 100 mm²/s (optimal ISO VG 46 at operating temp)
Oil Cleanliness Requirement ISO 4406 18/16/13 (NAS 1638 Class 8-9)
Net Weight (Approx.) ≈ 145-150 kg (dry, excl. coupling)
Package / Condition Original factory wooden crate, new unused, German import
Salable / Supply Region Global — Available via Rexroth authorized industrial hydraulics distributors (Europe, Americas, Asia-Pacific incl. China mainland)
Rexroth A4VSO250LR2 piston pump product image
A4VSO250LR2G/30R-PKD63N00E
A4VSO250LR2G/30R-PKD63N00E
A4VSO250LR2G/30R-PKD63N00E
A4VSO250LR2G/30R-PKD63N00E
A4VSO250LR2G/30R-PPB13N00
A4VSO250LR2G/30R-PPB13N00E
A4VSO250LR2G/30R-PPB13N00ESO168
A4VSO250LR2G/30R-VSD75U99E
A4VSO250LR2GF/30R-PKD63N00
A4VSO250LR2GF/30R-PPB13N00E
A4VSO250LR2H/30R-PKD63N00
A4VSO250LR2H/30R-PPB13N00E
A4VSO250LR2N/22R-PKD63K19
A4VSO250LR2N/30R-PKD63K21E
A4VSO250LR2N/30R-PKD63N00
A4VSO250LR2N/30R-PPB13N00E
A4VSO250LR2N/30R-PPB13N00E
A4VSO250LR2Z/30R-PPB13K59E
A4VSO250LR2Z/30R-PPB13N00
A4VSO250LR3G/30R-FKD75U99E
A4VSO250LR3G/30R-PKD63K78E
A4VSO250LR3N/30R+A4VSO250LR3N/30RE
A4VSO250LR3N/30R-PKD63K17
A4VSO250LR3N/30R-PPB13K01
A4VSO250LR3N/30R-PPB25K35E
A4VSO250LR3N/30R-PPB25N00E
A4VSO250LR3N/30R-PPB25N00E
A4VSO250LR3N/30R-PZB25N00E
A4VSO250LR3S/30R-PPB25K35E
A4VSO250LR3S/30R-PPB25N00E
A4VSO250LR3S/30R-PZB25K33E
A4VSO250MA/30R-PPB13N00
A4VSO250OV/30R-PKD63N00-SO55
A4VSO355DFE1/30R-VPB25K99E
A4VSO355DFE1/30R-VPB25U99E
A4VSO355DFR/22L-PSD63N00-SO481
A4VSO355DFR/30L-PRD63N00
A4VSO355DFR/30R-VKD63N00E
A4VSO355DFR/30R-VKD63N00E
A4VSO355DR/30R-FKD75U99
A4VSO355DR/30R-PKD63N00
A4VSO355DR/30R-PKD63N00E
A4VSO355DR/30R-PKD63N00E
A4VSO355DR/30R-PKD63N00ESO103

Model Code Breakdown
  • A4VSO — Axial piston variable pump, open circuit
  • 250 — Displacement 250 cm³/rev
  • LR2 — Constant power (horsepower) control, hyperbolic characteristic, mechanically adjustable start of power limiting
  • 30 — Design Series 30
  • L — Counter‑clockwise rotation (viewed from shaft end)
  • PPB25N00
    • PP — Through‑drive capable, ISO 4‑bolt flange, metric keyed shaft
    • B25 — SAE flange side ports (P & T 90° apart), second pressure port B1 plugged
    • N00 — No auxiliary pump / no special option on through‑drive

Frequently Asked Questions
What does LR2 (constant power / horsepower control) do?
LR2 is a hydro-mechanical constant power controller. The pump automatically reduces its displacement (flow) as system pressure rises, so that the product of Pressure × Flow ≈ constant (Power = const) — following a hyperbolic curve. This prevents the prime mover (electric motor / engine) from being overloaded. The starting point of power limiting is adjustable via a mechanical set screw on the LR2 controller. LR2 is purely mechanical/hydraulic — no electronics required.
How is LR2 different from DR (pressure control) or DFR (load-sensing)?
  • DR: Maintains constant pressure; pump strokes to near-zero when pressure setpoint is reached.
  • DFR / DFR1: Load-sensing + pressure limiting — adjusts flow to match demand.
  • LR2: Does NOT hold constant pressure; it limits total absorbed power. At low pressure the pump can deliver full flow; as pressure climbs the swash plate is mechanically forced back to keep P×Q below the set power limit. If system pressure is low, pump stays at full displacement.
Can I mount a second pump on the back?
Yes. The PPB code indicates through‑drive capability. You can flange-mount another A4VSO pump (same or smaller size) or a gear pump on the rear to form a tandem combination. N00 = no auxiliary gear pump pre-fitted, through-drive shaft is present.
What are critical installation points for LR2 pumps?
  • Case Drain: Plumb directly to tank, backpressure ≤ 1.5-2 bar. Never tee into main return.
  • Suction Line: Keep short & large-diameter; ensure absolute inlet pressure ≥ 0.8 bar to avoid cavitation. Use 100 µm suction strainer.
  • Rotation Check: "L" = counter‑clockwise when viewed from shaft end — verify prime mover direction before coupling.
  • LR2 Adjustment: Set the power-limiting screw so that P×Q at max pressure does not exceed motor rated power (allow ~10% margin for losses).
  • Bleed: Fill case and suction with oil and vent before first start-up.
Is a system relief valve still required with LR2?
Yes, absolutely. LR2 limits power but has no precise pressure cut-off function — it can allow pressure to rise above safe levels if flow demand drops to near zero and the control is misadjusted. A system safety relief valve (e.g. DB type, set above max working pressure + margin) is mandatory.
What oil cleanliness is required?
Maintain hydraulic oil at ISO 4406 18/16/13 (NAS 1638 Class 8 -9) minimum, using a return-line filter with β₁₀ ≥ 200 (10 µm nominal). Particle contamination is the leading cause of premature A4VSO pump failure.
What is the PPB25 port configuration?
B25 = SAE flange side ports with pressure port (B) and tank port (S) 90° apart, plus a second pressure port (B1) on the opposite side of B, normally plugged with a SAE flange blank. This allows cascade loading or superimposed signals in multi-pump systems.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)