| Max. Operating Pressure: | 315 Bar (Ports P, A, B) | Max. Flow Rate: | 60 L/min |
|---|---|---|---|
| Port Connection: | NG6 Interface | Sealing Material: | NBR (Standard For Mineral Oils) |
| Viscosity Range: | 2.8 - 500 Mm²/s (Optimal: 20 - 100 Mm²/s) | ||
| Highlight: | Rexroth manual directional valve,Rexroth hydraulic valve Germany,4WMM6E6X directional valve Rexroth |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer Part No. |
R983030727 |
|
Valve Type |
Manual Directional Spool Valve (Direct-Acting) |
|
Series / Platform |
WMM Series, Size NG6 (CETOP 03), Component Series 6X |
|
Spool Type |
E-Type (Defines center position flow pattern) |
|
Max. Operating Pressure |
315 bar (Ports P, A, B) |
|
Max. Flow Rate |
60 L/min (Recommended for standard pressure drop) |
|
Port Connection |
NG6 Interface (ISO 4401-03-02-0-05 / DIN 24340 Form A) |
|
Mounting |
Subplate Mounting (Base plate ordered separately) |
|
Actuation |
Manual Lever (Spring-Centered) |
|
Sealing Material |
NBR (Standard for mineral oils) |
|
Weight |
Approx. 1.4 kg |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HFC, HFD, HETG, HEES |
|
Viscosity Range |
2.8 - 500 mm²/s (Optimal: 20 - 100 mm²/s) |
|
Fluid Cleanliness |
ISO 4406 Class 20/18/15 (Recommended: Cleaner) |
![]()
| R901382331 4WRPEH 6 C4B12L-3X/M/24F1 |
| R901382332 4WRPEH 6 C4B24L-3X/M/24F1 |
| R901382333 4WRPEH 6 C4B40L-3X/M/24F1 |
| R901381804 4WRPEH 6 C B24L-3X/M/24A1 |
| R901382345 4WRPEH 6 C3B04L-3X/M/24A1 |
| R901382312 4WRPEH 6 C3B12L-3X/M/24A1 |
| R901382313 4WRPEH 6 C3B24L-3X/M/24A1 |
| R901382315 4WRPEH 6 C3B40L-3X/M/24A1 |
| R901382317 4WRPEH 6 C4B04L-3X/M/24A1 |
| R901382318 4WRPEH 6 C4B12L-3X/M/24A1 |
| R901382346 4WRPEH 6 C4B24L-3X/M/24A1 |
| R901382319 4WRPEH 6 C4B40L-3X/M/24A1 |
| R901382347 4WRPEH 6 C3B04L-3X/M/24F1 |
| R901382348 4WRPEH 6 C3B12L-3X/M/24F1 |
| R901382349 4WRPEH 6 C3B24L-3X/M/24F1 |
| R901382350 4WRPEH 6 C3B40L-3X/M/24F1 |
| R901382353 4WRPEH 6 CB40L-3X/M/24A1 |
| R901382354 4WRPEH 6 CB40L-3X/M/24F1 |
| R901382323 4WRPEH 6 C3B15P-3X/M/24A1 |
| R901382357 4WRPEH 6 C3B25P-3X/M/24A1 |
| R901382359 4WRPEH 6 C4B15P-3X/M/24A1 |
| R901382363 4WRPEH 6 C4B40P-3X/M/24A1 |
| R901396969 4WRPEH 6 C3 B04L-3X/M/24F1-885 |
| R901382372 4WRPEH 6 CB24L-3X/M/24F1 |
| R901382374 4WRPEH 6 CB04L-3X/M/24F1 |
| R901382511 4WRPEH 6 C3B15P-3X/M/24F1 |
| R901382376 4WRPEH 6 C B02L-3X/M/24F1 |
| R901382526 4WRPEH 6 C B24L-3X/V/24F1 |
| R901382368 4WRPEH 6 C5B40L-3X/M/24A1 |
| R901382370 4WRPEH 6 C5B24L-3X/M/24A1 |
| R901382336 4WRPEH 6 C3B02L-3X/M/24F1 |
| R901382361 4WRPEH 6 C4B25P-3X/M/24A1 |
| R901382369 4WRPEH 6 C5B40L-3X/M/24F1 |
| R900954062 4WRA 10 E1-30-2X/G24K4/V |
| R900954063 4WRA 10 E1-60-2X/G24K4/V |
| R900R908978 4WRA 10 E1-60-2X/G24N9K4/V |
| R900954060 4WRA 10 E30-2X/G24K4/V |
| R900921739 4WRA 10 E30-2X/G24N9K4/V |
| R900954061 4WRA 10 E60-2X/G24K4/V |
| R900R902097 4WRA 10 E60-2X/G24N9K4/V |
| R900926365 4WRA 10 E60-2X/G24N9K4/V-589 |
| R900954408 4WRA 10 EA30-2X/G24K4/V |
| R900954064 4WRA 10 EA60-2X/G24K4/V |
| R900917193 4WRA 10 EA60-2X/G24N9K4/V |
| R900944554 4WRA 10 EA60-2X/G24N9K4/V-589 |
| R900954066 4WRA 10 W1-30-2X/G24K4/V |
| R900954067 4WRA 10 W1-60-2X/G24K4/V |
| R900575765 4WRA 10 W1-60-2X/G24N9K4/V |
| R900577424 4WRA 10 W30-2X/G24K4/V |
| R900954065 4WRA 10 W60-2X/G24K4/V |
| R900931721 4WRA 10 W60-2X/G24K4/V-589 |
| R900R907650 4WRA 10 W60-2X/G24N9K4/V |
| R900943416 4WRA 10 W60-2X/G24N9K4/V-589 |
| R900954068 4WRA 10 WA30-2X/G24K4/V |
| R900952054 4WRA 10 WA60-2X/G24K4/V |
| R900R906030 4WRA 10 WA60-2X/G24K4/V-589 |
| R900910780 4WRA 6 E07-2X/G24K4/V |
| R900958793 4WRA 6 E07-2X/G24K4/V-589 |
| R900R906262 4WRA 6 E07-2X/G24N9K4/V |
| R900R904105 4WRA 6 E07-2X/G24N9K4/V-589 |
| R900954053 4WRA 6 E1-15-2X/G24K4/V |
| R900947835 4WRA 6 E1-30-2X/G24K4/V |
| R900954403 4WRA 6 E15-2X/G24K4/V-589 |
| R900R904438 4WRA 6 E15-2X/G24K4V |
| R900720405 4WRA 6 E30-2X/G24K4/V-589 |
| R900R904439 4WRA 6 E30-2X/G24K4V |
| R900R902940 4WRA 6 E30-2X/G24N9K4/V |
| R900921245 4WRA 6 E30-2X/G24N9K4/V-589 |
| R901154863 4WRA 6 E30-2X/G24XEJ/V |
| R900954054 4WRA 6 EA15-2X/G24K4/V |
| R90097R9038 4WRA 6 EA15-2X/G24N9K4/V-589 |
| R900954055 4WRA 6 EA30-2X/G24K4/V |
| R900963345 4WRA 6 EB07-2X/G24N9K4/V |
| R900924377 4WRA 6 EB30-2X/G24N9K4/V |
| R900953655 4WRA 6 V15-2X/G24N9K4/V-589 |
Q: What is the key feature of the "E" spool in 4WMM6E6X?
A: The letter "E" denotes the spool type, which defines the internal flow path pattern in the center (neutral) position. For the E-type spool, the typical configuration is P port connected to T port (tank), while A and B ports are closed. This provides "Open Center" unloading in the neutral position, allowing the pump to unload back to the tank while locking the actuator in place.
Q: What is the difference between 4WMM6E6X and 4WMM6D6X?
A: The difference lies in the spool type. The E-type typically has a P→T open center configuration, while the D-type (or other letters like O, M) has a different center position logic (e.g., all ports closed, or A/B open). Always check the specific symbol for the exact flow path.
Q: Does this valve have a detent (position lock)?
A: The standard 4WMM6E6X (without the /F suffix) is spring-centered. This means the lever must be held in the left or right position; when released, it automatically returns to the center (neutral) position. If you need the lever to stay in position, you would need the 4WMM6E6X/F variant.
Q: How is this valve mounted?
A: It is a subplate-mounted valve. It requires a separate NG6 base plate (mounting interface per ISO 4401-03-02-0-05) that is screwed onto the manifold or tank. The valve then mounts onto this base plate.
Q: What are the critical pressure limits?
A:
Port T Pressure: The return port (T) has a significantly lower pressure rating (160 bar) than the P, A, B ports (315 bar). Ensure your system's backpressure does not exceed this limit, as high backpressure can damage the valve and cause leakage.
Cleanliness: The valve contains precision spools. Install it only in a clean environment and flush the system thoroughly before commissioning.
Q: What is the standard port configuration?
A: The standard port configuration is:
P: Pressure In (from pump)
T: Tank Return
A, B: Work ports (to cylinder or motor)
Q: The lever is very hard to operate. What is wrong?
A: High operating force is usually due to:
High System Pressure: The spool is under pressure, creating a hydraulic lock. Operate the lever only when the system pressure is low or relieved.
Contamination: Dirt or varnish inside the valve can cause the spool to stick. Check the oil cleanliness (ISO 4406 Class 20/18/15 or cleaner is recommended).
Q: The cylinder drifts slowly when the valve is in the center position.
A: This is typically not a valve failure but a function of the E-type spool. The E-spool is designed to close A and B ports in the center. If drift occurs, it is likely due to:
Internal Leakage: Worn spool seals or a damaged cylinder.
Spool Wear: Contamination causing erosion of the spool edges, allowing internal leakage past the lands.
Q: There is external leakage from the shaft or mounting area.
A: This indicates worn shaft seals or a damaged O-ring between the valve and the subplate. The valve requires disassembly and resealing. Ensure the mounting bolts are torqued correctly to avoid warping the subplate.
Q: What type of oil and cleanliness are required?
A: Use ISO VG 32/46/68 mineral-based oils (HL, HLP). The oil cleanliness must be NAS Class 9 or cleaner (ISO 4406 18/16/13) for long service life. Contamination is the primary cause of spool sticking and wear.
Q: Can I repair this valve myself?
A: Limited repair is possible. Seal kits are available for replacing external O-rings and shaft seals. However, repairing or lapping the internal spool and body requires specialized equipment. For critical applications, replacing the valve is often more reliable than attempting a field repair.
Q: What is the expected service life?
A: Under correct conditions (clean oil, within pressure ratings), the mechanical life can be several million cycles. The primary failure modes are seal wear and spool sticking due to contamination.
Disclaimer: This data is based on standard Rexroth WMM series documentation. The exact center position flow pattern is defined by the "E" code, which should be verified with the supplier's datasheet. Always refer to the official technical data (RE 25706 or similar) for your specific application and safety guidelines.