Product Details:
Place of Origin: Germany
Brand Name: Rexroth
Certification: ISO
Model Number: R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Pilot operated proportional directional control valve from Rexroth Germany

Description
Rated Flow​: 200 L/min​ (at Δp = 10 Bar Per Control Land) Max. Flow​: Approx. 460 L/min​
Supply Voltage​: 24V DC​ (18...35 VDC) Control Signal​: ±10 V DC​ (Analog Voltage Input, /A1​ Suffix)
Feedback​: Electrical Spool Position Feedback (LVDT)​
Highlight:

Rexroth proportional directional control valve

,

Rexroth hydraulic valve with warranty

,

Pilot operated hydraulic control valve

Parameter

Specification

Order Number

R900727361

Model

4WRKE16E-200L-3X/6EG24EK31/A1D3M

Type

Pilot-operated, 2-stage proportional directional valve

Function

4/3-way (3 positions, 4 ports), spring-centered

Spool Type

E (Linear characteristic, with electrical position feedback)

Nominal Size

NG16​ (CETOP 7)

Max. Operating Pressure

P, A, B: 350 bar

Rated Flow

200 L/min​ (at Δp = 10 bar per control land)

Max. Flow

Approx. 460 L/min

Electronics

Integrated On-Board Electronics (OBE)

Supply Voltage

24V DC​ (18...35 VDC)

Control Signal

±10 V DC​ (Analog voltage input, /A1​ suffix)

Feedback

Electrical spool position feedback (LVDT)

Pilot Oil Supply

External (X)

Pilot Oil Return

External (Y)

Manual Override

No

Pressure Reducing Valve

Yes (D3, ZDR 6 DP0-4X/40YM)

Seal Material

NBR (M)

Electrical Connector

7-pin plug (DIN EN 175201-804, K31)

Mounting Interface

ISO 4401-07-07-0-05 (CETOP 7 subplate)

Suitable Media

Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR

Media Temperature

-20°C to +80°C​ (optimal 40–50°C)

Viscosity Range

20 to 380 mm²/s

Weight

Approx. 11.2 kg

R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M  Pilot operated proportional directional control valve from Rexroth Germany 0

4WRZE16E1-150-72/6EG24EK31/A1M
4WRZE16E1-150-72/6EG24ETK31/A1D3M
4WRZE16E1-150-72/6EG24ETK31/A1M
4WRZE16E1-150-72/6EG24K31/A1M
4WRZE16E1-150-72/6EG24N9EK31/A1D3M
4WRZE16E1-150-72/6EG24N9EK31/A1D3V
4WRZE16E1-150-72/6EG24N9EK31/A1M
4WRZE16E1-150-72/6EG24N9ETK31/A1D3V
4WRZE16E1-150-72/6EG24N9K31/A1D3M
4WRZE16E1-150-72/6EG24N9K31/A1M
4WRZE16E1-150-72/6EG24N9K31/A1V
4WRZE16E1-150-72/6EG24NJEK31/F1D3M
4WRZE16E150-72/6EG24EK31/A1D3M
4WRZE16E150-72/6EG24EK31/A1V
4WRZE16E150-72/6EG24ETK31/A1D3M
4WRZE16E150-72/6EG24ETK31/A1D3V
4WRZE16E150-72/6EG24ETK31/A1M
4WRZE16E150-72/6EG24K31/A1D3M
4WRZE16E150-72/6EG24K31/A1M
4WRZE16E150-72/6EG24N9EK31/A1D3M
4WRZE16E150-72/6EG24N9EK31/A1D3V
4WRZE16E150-72/6EG24N9EK31/A1M
4WRZE16E150-72/6EG24N9EK31/F1D3M
4WRZE16E150-72/6EG24N9ETK31/A1D3M
4WRZE16E150-72/6EG24N9ETK31/A1D3V
4WRZE16E150-72/6EG24N9ETK31/A1V
4WRZE16E150-72/6EG24N9K31/A1D3M
4WRZE16E150-72/6EG24N9K31/A1D3V
4WRZE16E150-72/6EG24N9K31/A1M
4WRZE16E150-72/6EG24N9K31/A1V
4WRZE16E150-72/6EG24TK31/A1M
4WRZE16E3-150-72/6EG24EK31/A1D3M
4WRZE16E3-150-72/6EG24N9TK31/A1M
4WRZE16EA150-72/6EG24ETK31/A1M
4WRZE16EA150-72/6EG24K31/A1D3M
4WRZE16EA150-72/6EG24K31/A1M
4WRZE16EA150-72/6EG24K31/F1V
4WRZE16EA150-72/6EG24N9ETK31/A1D3M
4WRZE16EB150-72/6EG24EK31/A1D3V
4WRZE16W6 150-72/6EG24K31/A1M
4WRZE16W6-100-72/6EG24ETK31/A1D3M
4WRZE16W6-100-72/6EG24ETK31/A1D3V
4WRZE16W6-100-72/6EG24ETK31/F1D3V
4WRZE16W6-100-72/6EG24K31/A1M
4WRZE16W6-100-72/6EG24K31/F1D3M
4WRZE16W6-100-72/6EG24N9ETK31/A1D3M
4WRZE16W6-100-72/6EG24N9ETK31/A1M
4WRZE16W6-100-72/6EG24N9ETK31/F1D3M
4WRZE16W6-100-72/6EG24N9ETK31/F1D3V
4WRZE16W6-100-72/6EG24N9K31/A1M
4WRZE16W6-100-72/6EG24N9K31/F1D3M
4WRZE16W6-100-72/6EG24N9K31/F1V
4WRZE16W6-100-72/6EG24N9TK31/F1D3M
4WRZE16W6-150-72/6EG24EK31/A1D3M
4WRZE16W6-150-72/6EG24EK31/A1M
4WRZE16W6-150-72/6EG24EK31/A1V
4WRZE16W6-150-72/6EG24EK31/F1D3M
4WRZE16W6-150-72/6EG24ETK31/A1D3M
4WRZE16W6-150-72/6EG24ETK31/A1M
4WRZE16W6-150-72/6EG24ETK31/F1D3M
4WRZE16W6-150-72/6EG24K31/A1D3M
4WRZE16W6-150-72/6EG24K31/A1V
4WRZE16W6-150-72/6EG24K31/F1D3M
4WRZE16W6-150-72/6EG24N9EK31/A1D3M
4WRZE16W6-150-72/6EG24N9EK31/A1M
4WRZE16W6-150-72/6EG24N9EK31/A1V
4WRZE16W6-150-72/6EG24N9EK31/F1D3M
4WRZE16W6-150-72/6EG24N9EK31/F1D3V
4WRZE16W6-150-72/6EG24N9EK31/F1V
4WRZE16W6-150-72/6EG24N9ETK31/A1D3M
4WRZE16W6-150-72/6EG24N9ETK31/A1D3V

FAQ:

  1. Pilot Oil Configuration (/6EG24EK31)

    This valve uses external pilot oil supply (X port) and external pilot oil return (Y port). You must provide clean, filtered pilot oil to the X port (25–315 bar) and ensure the Y port drains directly to the tank with minimal backpressure (max 10 bar).

  2. Control Signal (/A1)

    The /A1​ suffix indicates a ±10 V voltage input. This is ideal for high-precision control systems (e.g., servo controllers) where fine resolution and fast signal response are required.

  3. Integrated Pressure Reducing Valve (/D3)

    The /D3​ option includes an integrated ZDR 6​ pressure reducing valve. It ensures the pilot stage receives a stable, reduced pressure (typically around 40 bar), protecting the sensitive pilot valve from high and fluctuating main system pressures.

  4. Critical Installation Notes

    • Drain Line:​ The external pilot drain (Y port) must be connected directly to the tank with a dedicated line. Backpressure on Y must be < 10 bar.

    • Cleanliness:​ Maintain high oil cleanliness (recommended NAS 1638 Class 8 or ISO 4406 20/18/15 for the main stage).

    • Pilot Supply:​ Provide clean, regulated pilot pressure to the X port.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)