logo
Home ProductsRexroth Hydraulic Valve

R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve

I'm Online Chat Now

R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve

R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve
R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve

Large Image :  R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve

Description
Weight​: 8.7 Kg Pilot Oil Supply​: External (X)​
Feedback: Electrical Spool Position Feedback (LVDT, /ET)​ Control Signal​: 4–20 MA​ (Analog Current Input, /F1​ Suffix)
Supply Voltage​: 24V DC​ (18...35 VDC)
Highlight:

Rexroth hydraulic proportional solenoid valve

,

Rexroth directional valve with warranty

,

German Rexroth 4WRKE10W6 hydraulic valve


Parameter

Specification

Order Number

R901202900

Model

4WRKE10W6-25L-3X/6EG24ETK31/F1D3M

Type

Pilot-operated, 2-stage proportional directional valve

Function

4/3-way (3 positions, 4 ports), spring-centered

Spool Type

W6 (Linear characteristic, position feedback)

Nominal Size

NG10​ (CETOP 5)

Max. Operating Pressure

P, A, B: 350 bar

Rated Flow

25 L/min​ (at Δp = 10 bar per control land)

Max. Flow

Approx. 170 L/min

Electronics

Integrated On-Board Electronics (OBE)

Supply Voltage

24V DC​ (18...35 VDC)

Control Signal

4–20 mA​ (Analog current input, /F1​ suffix)

Feedback

Electrical spool position feedback (LVDT, /ET)

Pilot Oil Supply

External (X)

Pilot Oil Return

External (Y)

Manual Override

No

Pressure Reducing Valve

Yes (D3, ZDR 6 DP0-4X/...)

Seal Material

NBR (M)

Electrical Connector

7-pin plug (DIN EN 175201-804, K31)

Mounting Interface

ISO 4401-05-04-0-05 (CETOP 5 subplate)

Suitable Media

Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR

Media Temperature

-20°C to +80°C​ (optimal 40–50°C)

Viscosity Range

20 to 380 mm²/s

Weight

Approx. 8.7 kg

R901202900 4WRKE10W6-25L-3X/6EG24ETK31/F1D3M German Rexroth hydraulic proportional solenoid directional valve 0

4WRZE10E25-72/6EG24ETK31/A1D3M
4WRZE10E25-72/6EG24N9EK31/A1D3V
4WRZE10E50-72/6EG24ETK31/A1D3M
4WRZE10E50-72/6EG24N9EK31/A1D3V
4WRZE10E50-72/6EG24N9ETK31/A1D3V
4WRZE10E50-72/6EG24N9ETK31/F1D3M
4WRZE10E50-72/6EG24N9K31/A1M
4WRZE10E50-72/6EG24N9K31/F1V
4WRZE10E85-72/6EG24EK31/A1D3M
4WRZE10E85-72/6EG24EK31/A1M
4WRZE10E85-72/6EG24ETK31/A1D3M
4WRZE10E85-72/6EG24ETK31/F1D3M
4WRZE10E85-72/6EG24K31/A1M
4WRZE10E85-72/6EG24N9EK31/A1D3M
4WRZE10E85-72/6EG24N9EK31/A1D3V
4WRZE10E85-72/6EG24N9EK31/A1M
4WRZE10E85-72/6EG24N9EK31/F1D3M
4WRZE10E85-72/6EG24N9ETK31/A1D3M
4WRZE10E85-72/6EG24N9ETK31/A1D3V
4WRZE10E85-72/6EG24N9ETK31/A1D3WG152V
4WRZE10E85-72/6EG24N9ETK31/A1M
4WRZE10E85-72/6EG24N9ETK31/A1V
4WRZE10E85-72/6EG24N9K31/A1M
4WRZE10E85-72/6EG24N9K31/A1V
4WRZE10E85-72/6EG24N9K31/F1M
4WRZE10EA50-72/6EG24EK31/A1D3M
4WRZE10EA50-72/6EG24N9EK31/A1D3M
4WRZE10EA85-72/6EG24EK31/A1D3M
4WRZE10EA85-72/6EG24ETK31/A1D3M
4WRZE10EA85-72/6EG24N9EK31/A1D3M
4WRZE10EA85-72/6EG24N9EK31/A1D3V
4WRZE10EA85-72/6EG24TK31/A1D3M
4WRZE10W6-25-72/6EG24N9EK31/A1D3M
4WRZE10W6-50-72/6EG24ETK31/A1D3M
4WRZE10W6-50-72/6EG24ETK31/F1D3V
4WRZE10W6-50-72/6EG24K31/F1D3M
4WRZE10W6-50-72/6EG24N9EK31/A1D3M
4WRZE10W6-50-72/6EG24N9EK31/F1D3M
4WRZE10W6-50-72/6EG24N9EK31/F1V
4WRZE10W6-50-72/6EG24N9ETK31/A1D3V
4WRZE10W6-50-72/6EG24N9ETK31/A1M
4WRZE10W6-50-72/6EG24N9ETK31/F1D3M
4WRZE10W6-50-72/6EG24N9ETK31/F1D3V
4WRZE10W6-50-72/6EG24N9K31/F1D3V
4WRZE10W6-50-72/6EG24N9K31/F1V
4WRZE10W6-85-7/6EG24EK31/A1D3M
4WRZE10W6-85-72/6EG24EK31/F1D3M
4WRZE10W6-85-72/6EG24ETK31/A1D3M
4WRZE10W6-85-72/6EG24ETK31/F1D3M
4WRZE10W6-85-72/6EG24K31/A1D3M
4WRZE10W6-85-72/6EG24K31/F1D3M
4WRZE10W6-85-72/6EG24N9EK31/A1M
4WRZE10W6-85-72/6EG24N9EK31/F1D3M
4WRZE10W6-85-72/6EG24N9ETK31/A1D3M
4WRZE10W6-85-72/6EG24N9ETK31/A1D3V
4WRZE10W6-85-72/6EG24N9ETK31/F1D3M
4WRZE10W6-85-72/6EG24N9K31/A1D3M
4WRZE10W6-85-72/6EG24N9K31/A1V
4WRZE10W6-85-72/6EG24N9K31/F1D3M
4WRZE10W6-85-72/6EG24N9TK31/A1D3M
4WRZE10W8-50-72/6EG24ETK31/A1D3M
4WRZE10W8-50-72/6EG24N9EK31/F1D3M
4WRZE10W8-50-72/6EG24N9ETK31/A1M
4WRZE10W8-50-72/6EG24N9ETK31/F1D3M
4WRZE10W8-50-72/6EG24N9K31/A1D3M
4WRZE10W8-50-72/6EG24N9K31/A1M
4WRZE10W8-50-72/6EG24N9K31/F1D3M
4WRZE10W8-50-72/6EG24N9K31/F1M

FAQ:

  1. Q: What is the main difference between 4WRKE and the previous 4WRZE valves?

    A:​ The 4WRKE series​ features electrical position feedback (/ET)​ of the main spool, which allows for closed-loop position control. This provides higher accuracy and repeatability compared to the open-loop 4WRZE series. Additionally, this model is NG10 size, making it suitable for lower flow applications (25 L/min rated) than the NG25/32 valves.

  2. Q: How does the pilot oil configuration work?

    A:​ This valve (/6EG24ETK31) uses external pilot oil supply (X port) and external pilot oil return (Y port). You must provide clean, filtered pilot oil to the X port (typically 25–315 bar) and ensure the Y port drains directly to the tank with minimal backpressure (max 10 bar).

  3. Q: Why choose the /F1 version?

    A:​ The /F1​ suffix (4–20 mA current input) is ideal for noisy industrial environments​ or when the control signal must travel long distances. It is less susceptible to voltage drop and electromagnetic interference than voltage signals (±10 V).

  4. Q: What is the role of the /D3 pressure reducing valve?

    A:​ The /D3​ option is an integrated, fixed-setting pressure reducing valve (ZDR 6). It ensures the pilot stage receives a stable, reduced pressure (typically around 40 bar), protecting the sensitive pilot valve from high and fluctuating main system pressures.

  5. Q: What is the critical installation note?

    A:​ You must connect the external pilot drain (Y port) directly to the tank​ with a dedicated line. Backpressure on the Y port must be below 10 bar​ to ensure proper pilot valve function. Provide clean, regulated pilot pressure to the X port. Maintain high oil cleanliness (recommended NAS 1638 Class 8 or ISO 4406 20/18/15 for the main stage).

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)