logo
Dom ProduktyPompy hydrauliczne Rexroth

PV7-1X/63-94RE07MC5-08 PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot

Im Online Czat teraz

PV7-1X/63-94RE07MC5-08 PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot

PV7-1X/63-94RE07MC5-08 
PV7-1X/10-14RE01MC3-16	
PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot
PV7-1X/63-94RE07MC5-08 
PV7-1X/10-14RE01MC3-16	
PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot PV7-1X/63-94RE07MC5-08 
PV7-1X/10-14RE01MC3-16	
PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot

Duży Obraz :  PV7-1X/63-94RE07MC5-08 PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot

Szczegóły Produktu:
Miejsce pochodzenia: Niemcy
Nazwa handlowa: Rexroth
Orzecznictwo: ISO
Numer modelu: PV7-1X/63-94RE07MC5-08 PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16
Zapłata:
Minimalne zamówienie: 1
Szczegóły pakowania: Drewniane pudełko
Czas dostawy: 2 tygodnie
Zasady płatności: Western Union, T/T, D/P, D/A, L/C.
Możliwość Supply: 100

PV7-1X/63-94RE07MC5-08 PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16 Pilot vane pump Rexroth Germany spot PV7 series hydraulic oil pump spot

Opis
Maksymalna prędkość: 1800–3600 obr./min (w zależności od pojemności skokowej i lepkości płynu) Minimalna prędkość: 600 obr./min (zapewnia stabilną pracę)
Medium płynne: Płyn hydrauliczny na bazie oleju mineralnego (zalecana norma ISO VG 32/46/68) Zakres temperatur płynów: '-20°C do +80°C (praca); -40°C do +90°C (przechowywanie)
Zakres lepkości: 10–1000 mm²/s (praca); 2–1500 mm²/s (rozruch)
Podkreślić:

Rexroth PV7 vane pump

,

hydraulic oil vane pump

,

PV7 series pilot vane pump

Rexroth PV7 Series Vane Pumps
Featured Models: PV7-1X/63-94RE07MC5-08, PV7-1X/10-14RE01MC3-16, PV7-1X/40-45RE37MD0-16
Technical Specifications
Parameter/Property Category Direct-Acting (PV7-A) Series Pilot-Operated (PV7-C/D/N/W) Series Unit Remarks
Model Range PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 - 1X/2X=component series; 06/14/20=frame size
Displacement per Revolution 10-25 14-150 cm³/rev Displacement varies by specific model suffix
Max. Continuous Working Pressure 100 160 bar PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar
Max. Peak Pressure 120 200 bar Short-term (≤5s) overload only
Speed Range 600-2800 600-3600 rpm Higher speed for smaller displacement models
Max. Flow Rate (at 1800 rpm) 36 270 l/min Calculated at rated displacement
Volumetric Efficiency (Rated Condition) ≥90% ≥92% % At 160 bar, 1800 rpm, ISO VG 46 oil
Total Efficiency (Nominal Operation) ≥80% ≥82% % Includes mechanical & volumetric efficiency
Suction Pressure Range 1 -0.8 to +1 bar Absolute pressure: 0.2-1.1 bar
Fluid Compatibility Mineral oil (HLP), synthetic oil (HETG/HEES) Mineral oil (HLP), synthetic oil (HETG/HEES) - Use FKM seals for synthetic fluids
Fluid Viscosity Range 10-1000 (operation); 2-1500 (start-up) 10-1000 (operation); 2-1500 (start-up) mm²/s Optimal: 16-160 mm²/s
Fluid Temperature Range - -20 to +80 °C Storage: -40 to +90 °C
Noise Level (1 m Distance, Rated Operation) ≤63 ≤65 dB(A) Pilot-operated models have optimized noise reduction
Mounting Standard ISO 3019-2 flange ISO 3019-2 flange - Optional foot mounting for some models
Shaft Connection ISO 4162 splined shaft ISO 4162 splined shaft - Keyed shaft available on request
Seal Material NBR (standard); FKM (optional) NBR (standard); FKM (optional) - NBR for mineral oil; FKM for synthetic oil
Weight 8-12 10-35 kg Depends on displacement and control type
Control Type Direct-acting pressure compensation Pilot-operated pressure/flow control - PV7-A: direct-acting; PV7-C/D/N/W: pilot-operated
PV7-1X/63
<section>
<div class=Available Model Variants
  • PV7-1X/25-45RE01MC0-08-P25Q50
  • PV7-1X/40-71RE37MC5-08
  • PV7-1X/10-14RE01KD0-16
  • PV7-1X/16-20RE01MC0-16-P120
  • PV7-1X/100-150RE07MW0-08WH
  • PV7-1X/16-20RE01MC5-16WG
  • PV7-1X/10-20RE01MW0-10WH
  • PV7-1X/63-94RE07KD0-08
  • PV7-1X/63-71RE07MW0-16WH
  • PV7-1X/63-71RE07MC7-16WH
  • PV7-1X/40-45RE37MC0-16
  • PV7-1X/63-94RE07MC0-08-P80Q114
  • PV7-1X/40-45RE37MC5-16WH
  • PV7-1X/10-14RE01KN0-16
  • PV7-1X/25-30RE01MC5-16WH
  • PV7-1X/63-71RE07KC0-16
  • PV7-1X/10-20RE01MC3-10
  • PV7-1X/16-20RE01MN0-16
  • PV7-1X/25-45RE01MW0-08WH
  • PV7-1X/63-71RE07MN0-16
  • PV7-1X/63-71RE07KD0-16
  • PV7-1X/16-20RE01MC8-16
  • PV7-1X/40-71RE37MW0-08WH
  • PV7-1X/40-45RE37MD0-16-P50Q36
  • PV7-1X/40-45RE37MC7-16WG
  • PV7-1X/100-118RE07MN5-16
  • PV7-1X/25-45RE01MC7-08WG
  • PV7-1X/63-71RE07MC7-16
  • PV7-1X/100-150RE07MC3-08
  • PV7-1X/40-45RE37KC0-16
  • PV7-1X/63-94RE07MC5-08
  • PV7-1X/16-20RE01MC0-16-P60Q26
  • PV7-1X/16-20RE01MC5-16
  • PV7-1X/40-71RE37MC5-08WG
  • PV7-1X/25-45RE01MC7-08
  • PV7-1X/25-30RE01MW5-16WH
  • PV7-1X/10-20RE01MD0-10
  • PV7-1X/63-71RE07MD0-16-Q90
  • PV7-1X/16-30RE01MC3-08
  • PV7-1X/100-150RE07MC7-08
  • PV7-1X/100-118RE07MN0-16
  • PV7-1X/10-20RE01MC5-10
  • PV7-1X/25-30RE01MC5-16WH-A234
  • PV7-1X/100-150RE07MC5-08WH
  • PV7-1X/25-30RE01MW0-16WH
  • PV7-1X/10-20RE01MC7-10WH
  • PV7-1X/25-45RE01MC5-08
  • PV7-1X/40-45RE37MC8-16
  • PV7-1X/16-20RE01MW0-16WH
  • PV7-1X/16-20RE01MC3-16-P50Q25
  • PV7-1X/100-118RE07KC0-16
  • PV7-1X/40-71RE37MC5-08WH
  • PV7-1X/100-118RE07MC6-16
  • PV7-1X/40-71RE37MC3-08
  • PV7-1X/40-71RE37MC7-08WH
  • PV7-1X/10-14RE01MW0-16WH
  • PV7-1X/10-20RE01MC3-10-A497
  • PV7-1X/16-20RE01MC3-16
  • PV7-1X/16-20RE01MC5-16WH
  • PV7-1X/63-71RE07MC3-06-A460
  • PV7-1X/16-30RE01MC5-08WH
  • PV7-1X/10-14RE01MC0-16-P100
  • PV7-1X/63-94RE07MC5-08WH
  • PV7-1X/10-14RE01MC3-16
  • PV7-1X/40-45RE37MD0-16
  • PV7-1X/100-118RE07MC7-16WH
  • PV7-1X/25-45RE01MC5-08WH
  • PV7-1X/16-20RE01MC0-16
  • PV7-1X/63-71RE07MC5-16WG
  • PV7-1X/63-71RE07KC3-16
  • PV7-1X/10-20RE01MC5-10WH
  • PV7-1X/16-20RE01MC7-16
  • PV7-1X/10-14RE01MC7-16
  • PV7-1X/63-94RE07MC0-08
  • PV7-1X/16-20RE01MC0-16-P100Q29
  • PV7-1X/25-30RE01MC0-16-P100Q36
  • PV7-1X/40-45RE37MW5-16WH
  • PV7-1X/10-14RE01MC0-16-P45
  • PV7-1X/25-45RE01MN0-08
  • PV7-1X/25-30RE01MC0-16
  • PV7-1X/63-94RE07MC0-08-P75
  • PV7-1X/63-71RE07MW5-16WH
  • PV7-1X/25-30RE01MC5-16
  • PV7-1X/40-71RE37MD0-08
  • PV7-1X/100-150RE07MD0-08
  • PV7-1X/10-20RE01MC7-10
  • PV7-1X/10-14RE01MD3-16
  • PV7-1X/100-118RE07MW0-16WH
  • PV7-1X/100-118RE07KD0-16
  • PV7-1X/10-14RE01MC5-16
  • PV7-1X/63-94RE07MN0-08
  • PV7-1X/10-14RE01KC0-16
  • PV7-1X/40-45RE37MC3-16
  • PV7-1X/40-45RE37MC7-16
  • PV7-1X/16-20RE01MC0-16-C3.1
  • PV7-1X/40-45RE37MC0-16-A446
  • PV7-1X/100-118RE07MW0-16WG
  • PV7-1X/100-150RE07MC0-08
  • PV7-1X/63-94RE07MC5-08WG
  • PV7-1X/16-20RE01KC0-16
  • PV7-1X/40-55RE37MC0-08-A449
  • PV7-1X/63-94RE07MD0-08
  • PV7-1X/16-20RE01MD0-16-Q25
  • PV7-1X/40-45RE37MD0-16-P50Q39
  • PV7-1X/63-71RE07MD0-16-Q65
  • PV7-1X/16-30RE01MC0-08
Frequently Asked Questions
Does Rexroth PV7 vane pump need special startup procedures?
No, thanks to its good self-priming capability, it can start quickly without complex procedures.
Can Rexroth PV7 vane pump adapt to sudden load changes?
Yes, it can respond quickly to sudden load changes and maintain stable performance.
Is Rexroth PV7 vane pump affected by ambient humidity?
Its corrosion-resistant design allows it to work normally in high-humidity environments.
What is the flow rate stability of Rexroth PV7 vane pump like?
It delivers consistent flow rate even when the system pressure changes.
Does Rexroth PV7 vane pump require professional maintenance personnel?
Its simple structure allows for routine maintenance without professional personnel, but complex repairs are recommended to be done by professionals.

Szczegóły kontaktu
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Osoba kontaktowa: Mr. liyun

Tel: +8615280488899

Wyślij zapytanie bezpośrednio do nas (0 / 3000)