Productdetails:
|
| Stroom: | Hydraulisch | Theorie: | Roterende pomp |
|---|---|---|---|
| Afdichtingstype: | Lipafdichting of mechanische afdichting | Leveringsdatum: | 5 dagen |
| Astype: | Gesplitst | Gebruik: | Olie |
| Montagetype: | Flens | Maximale druk: | 280 bar |
| Gewicht: | 12 kg | Handelsmerk: | Mks |
| Woningmateriaal: | gietijzer | ||
| Markeren: | Rexroth proportional hydraulic valve,German made solenoid valve,Rexroth directional valve with warranty |
||
Rexroth German made solenoid valve
4WRZ10E1-50-7X/6EG24N9ETK4/M
4WREE10WA75-2X/G24K31/F1V
4WREE10WA50-2X/G24K31/F1V
| Processing & Customization | Yes |
|---|---|
| Type | Proportional valve |
| Material | Cast steel |
| Brand | REXROTH |
| Scope of Application | Hydraulic system |
| Applicable Medium | Oil products |
| Applicable Temperature | Normal temperature (℃) |
| Nominal Pressure | Normal pressure (MPa) |
| Nominal Diameter | 6-way diameter (mm) |
| Installation type | Threaded installation |
| Operating Temperature | Room temperature |
| Type (channel location) | Straight through type |
A: Order Rexroth's original seal kits, disassemble the valve, remove old seals, clean seal grooves, and install new seals (ensure compatibility with hydraulic fluid).
A: Air in the hydraulic system, fluctuating input signal, contaminated fluid, worn spool, or faulty position feedback sensor.
A: Operate the valve at low pressure with the actuator extended/retracted fully, opening bleeder valves (if available) until a steady fluid flow (without bubbles) is observed.
A: Excessive pressure drop, blocked drain port, insufficient fluid flow, or a faulty solenoid drawing excess current.
A: Measure the feedback signal (e.g., 4-20 mA) while shifting the spool manually; the signal should change proportionally to spool travel. No change indicates a faulty sensor.