Thông tin chi tiết sản phẩm:
|
| Mã sản phẩm: | R900409898 | lắp: | Sandwich / Xếp chồng lên nhau |
|---|---|---|---|
| Tối đa. Áp lực: | 350 bar | Dòng chảy: | 60 L/phút |
| Điện áp: | 24V DC (tiêu chuẩn) |
|
Parameter |
Description |
|---|---|
|
Model |
ZDB6VP2-4X/315V |
|
Product Code |
R900409898 |
|
Type |
Stacked, pilot-operated relief/unloading valve |
|
Origin |
Germany |
|
Mounting |
Sandwich / Stacked |
|
Max. Pressure |
350 bar |
|
Set Pressure |
315 bar |
|
Flow |
60 L/min |
|
Pilot Stage |
VP2 (two-stage pilot) |
|
Control |
4X: Solenoid, external pilot supply & drain |
|
Voltage |
24V DC (standard) |
|
Main Application |
Electrically controlled unloading on directional valve stacks |
![]()
| R900506373 ZDB10VB3-4X/100V |
| R900501402 ZDBK6VA2-1X/100V |
| R900501258 ZDB10VA1-4X/200 |
| R900449008 ZDB6VP1-4X/50V |
| R900440160 ZDB6VB3-4X/50V |
| R900437441 ZDB6VA2-4X/100 |
| R900433646 ZDB6VA1-4X/200V |
| R900432106 ZDB10VA2-4X/50 |
| R900431678 ZDB6VA2-4X/50 |
| R900431401 ZDB6VB2-4X/100 |
| R900431071 ZDB6VA2-4X/315 |
| R900430984 ZDB10VA2-4X/315 |
| R900429509 ZDB6VB2-4X/200 |
| R900428468 ZDB10VP2-4X/200 |
| R900428339 ZDB6VP2-4X/200 |
| R900427434 ZDB10VA2-4X/100 |
| R900425927 ZDB10VP2-4X/315 |
| R900425681 ZDB10VB2-4X/315 |
| R900424537 ZDB10VA2-4X/100V |
| R900423274 ZDB6VP2-4X/100 |
| R900422752 ZDB10VP2-4X/50V |
| R900422261 ZDB10VB2-4X/200 |
| R900422215 ZDB10VB2-4X/200V |
| R900422189 ZDB10VA2-4X/200V |
| R900422089 ZDB6VP3-4X/200 |
| R900422075 ZDB6VP2-4X/315 |
| R900422073 ZDB10VB2-4X/100 |
| R900422061 ZDB6VB2-4X/315 |
| R900409959 ZDB10VP2-4X/100V |
| R900409958 ZDB10VP2-4X/315V |
| R900409956 ZDB10VB2-4X/315V |
| R900409955 ZDB10VA2-4X/315V |
| R900409951 ZDB10VB2-4X/100V |
| R900409936 ZDB6VB2-4X/100V |
| R900409933 ZDB6VP2-4X/100V |
What is it?
A high-pressure, electrically controlled unloading valve in a stacked design. It is the 315 bar version of the ZDB6 series.
Key specs?
Type: Stacked, solenoid-controlled relief/unloading valve.
Pressure: Set to 315 bar.
Flow: 60 L/min.
Voltage: 24V DC.
How does it work?
It mounts between a directional valve and its subplate. When energized, its solenoid vents the pilot pressure, causing the valve to open and unload the pump to tank (near 0 bar). De-energizing it restores the 315 bar system pressure.
Main use?
Integrated pump unloading on directional valve stacks in high-pressure systems (e.g., presses, plastic machinery) to save energy when the system is idle.
How is it installed?
It is sandwiched in the valve stack. Ensure the external pilot supply (X) and drain (Y) are correctly connected to a clean, stable pressure source and tank.
Troubleshooting tips?
Won't unload: Check solenoid coil and voltage.
Pressure too low: Check pilot pressure or for internal leakage/contamination.
Noisy: Low pilot pressure or air in the system.
Người liên hệ: Mr. liyun
Tel: +8615280488899