Ürün ayrıntıları:
|
| Sipariş Numarası: | R900743953 | Model: | 4WRKE25W8-350L-3X/6EG24ETK31/F1D3M |
|---|---|---|---|
| Tip: | Pilot kumandalı, 2 kademeli oransal yön valfi | İşlev: | 4/3 yollu (3 konum, 4 bağlantı noktası), yay merkezli |
| Nominal Akış: | 350 L/dak (kontrol alanı başına Δp = 10 bar'da) | ||
| Vurgulamak: | Rexroth oransal yön valfi,Garantili Rexroth hidrolik valf,4WRKE25W8 oransal valf |
||
|
Parametre |
Teknik Özellik |
|---|---|
|
Sipariş Numarası |
R900743953 |
|
Model |
4WRKE25W8-350L-3X/6EG24ETK31/F1D3M |
|
Tip |
Pilot kumandalı, 2 kademeli oransal yön kontrol valfi |
|
Fonksiyon |
4/3 yollu (3 pozisyonlu, 4 portlu), yay merkezli |
|
Bobin Tipi |
W8 (Kapalı bobin, elektriksel pozisyon geri beslemeli) |
|
Nominal Boyut |
NG25 (CETOP 8) |
|
Maks. Çalışma Basıncı |
P, A, B: 350 bar |
|
Nominal Akış |
350 L/dak (kontrol yüzeyi başına Δp = 10 bar'da) |
|
Maks. Akış |
Yaklaşık. 870 L/dak |
|
Elektronik |
Entegre Yerleşik Elektronik (OBE) |
|
Besleme Gerilimi |
24V DC (18...35 VDC) |
|
Kontrol Sinyali |
4–20 mA (Analog akım girişi, /F1 soneki) |
|
Geri Besleme |
Elektriksel bobin pozisyon geri beslemesi (LVDT, /ET) |
|
Pilot Yağ Beslemesi |
Harici (X) |
|
Pilot Yağ Dönüşü |
Harici (Y) |
|
Manuel Kumanda |
Hayır |
|
Basınç Düşürücü Valf |
Evet (D3, ZDR 6 DP0-4X/40YM) |
|
Conta Malzemesi |
NBR (M) |
|
Elektrik Konnektörü |
7-pin fiş (DIN EN 175201-804, K31) |
|
Montaj Arayüzü |
ISO 4401-08-07-0-94 (CETOP 8 alt plaka) |
|
Uygun Ortamlar |
Mineral yağlar (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR |
|
Ortam Sıcaklığı |
-20°C ila +80°C (optimal 40–50°C) |
|
Viskozite Aralığı |
20 ila 380 mm²/s |
|
Ağırlık |
Yaklaşık. 17 kg |
![]()
| 4WRZE25W6-325-72/6EG24N9K31/F1M |
| 4WRZE25W6-325-72/6EG24N9K31/F1V |
| 4WRZE25W6-325-72/6EG24N9TK31/A1D3M |
| 4WRZE25W6-325-72/6EG24N9TK31/F1D3V |
| 4WRZE25W8-220-72/6EG24EK31/A1D3M |
| 4WRZE25W8-220-72/6EG24EK31/F1D3M |
| 4WRZE25W8-220-72/6EG24ETK31/A1D3M |
| 4WRZE25W8-220-72/6EG24K31/A1D3M |
| 4WRZE25W8-220-72/6EG24K31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9EK31/A1D3M |
| 4WRZE25W8-220-72/6EG24N9EK31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9ETK31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9ETK31/F1D3V |
| 4WRZE25W8-220-72/6EG24N9K31/A1D3V |
| 4WRZE25W8-220-72/6EG24N9K31/A1M |
| 4WRZE25W8-220-72/6EG24N9K31/F1D3M |
| 4WRZE25W8-325-72/6EG24EK31/A1D3M |
| 4WRZE25W8-325-72/6EG24EK31/F1D3M |
| 4WRZE25W8-325-72/6EG24ETK31/A1D3M |
| 4WRZE25W8-325-72/6EG24ETK31/F1M |
| 4WRZE25W8-325-72/6EG24K31/A1D3M |
| 4WRZE25W8-325-72/6EG24K31/A1M |
| 4WRZE25W8-325-72/6EG24N9EK31/A1D3M |
| 4WRZE25W8-325-72/6EG24N9EK31/A1D3V |
| 4WRZE25W8-325-72/6EG24N9EK31/A1V |
| 4WRZE25W8-325-72/6EG24N9EK31/F1D3M |
| 4WRZE25W8-325-72/6EG24N9EK31/F1D3V |
| 4WRZE25W8-325-72/6EG24N9ETK31/F1D3M |
| 4WRZE25W8-325-72/6EG24N9ETK31/F1D3V |
| 4WRZE25W8-325-72/6EG24N9K31/A1D3M |
| 4WRZE25W8-325-72/6EG24N9K31/A1M |
| 4WRZE25W8-325-72/6EG24N9K31/F1D3M |
| 4WRZE25W9-220-72/6EG24N9EK31/A1D3M |
| 4WRZE25W9-220-72/6EG24N9EK31/A1D3V |
| 4WRZE25W9-220-72/6EG24N9ETK31/A1D3V |
| 4WRZE25W9-220-72/6EG24N9K31/A1D3M |
| 4WRZE25W9-220-72/6EG24N9K31/F1D3M |
| 4WRZE25W9-325-72/6EG24N9EK31/A1D3M |
| 4WRZE25W9-325-72/6EG24N9K31/A1D3M |
| 4WRZE32E1-360-72/6EG24ETK31/A1D3M |
| 4WRZE32E1-520-72/6EG24ETK31/A1D3M |
| 4WRZE32E1-520-72/6EG24N9K31/A1D3M |
| 4WRZE32E360-72/6EG24ETK31/A1D3M |
| 4WRZE32E360-72/6EG24K31/A1M |
| 4WRZE32E520-72/6EG24EK31/A1D3M |
| 4WRZE32E520-72/6EG24EK31/F1D3M |
| 4WRZE32E520-72/6EG24ETK31/A1D3M |
| 4WRZE32E520-72/6EG24K31/A1D3M |
| 4WRZE32E520-72/6EG24N9ETK31/A1M |
| 4WRZE32E520-72/6EG24N9K31/A1D3V |
| 4WRZE32E520-72/6EG24N9TK31/A1D3M |
| 4WRZE32EA520-72/6EG24ETK31/A1M |
| 4WRZE32EB520-72/6EG24N9K31/A1D3M |
| 4WRZE32W6-360-72/6EG24ETK31/A1D3M |
| 4WRZE32W6-360-72/6EG24N9ETK31/F1D3M |
| 4WRZE32W6-360-72/6EG24N9K31/A1D3M |
| 4WRZE32W6-360-72/6EG24N9TK31/F1D3M |
SSS:
Bobin Tipi (W8)
W8 bobini, kapalı bir bobindir (pozitif sızdırmazlık). Bu tasarım, valf merkez konumdayken dahili sızıntıyı en aza indirir ancak hareketi başlatmak için daha yüksek bir ölü bant kontrol sinyali gerektirir. Valfin merkez konumda tutulmasının ve minimum sızıntının kritik olduğu uygulamalar için uygundur.
Kontrol Sinyali (/F1)
/F1 soneki, 4–20 mA akım girişi anlamına gelir. Bu sinyal türü, elektriksel gürültüye ve uzun kablo mesafelerindeki voltaj düşüşüne daha az duyarlıdır, bu da onu zorlu endüstriyel ortamlar için ideal kılar.
Pilot Yağ Yapılandırması (/6EG24ETK31)
Bu valf, harici pilot yağ beslemesi (X portu) ve harici pilot yağ dönüşü (Y portu) kullanır. X portuna (25–315 bar) temiz, filtrelenmiş pilot yağ sağlamalı ve Y portunun minimum geri basınçla (maks. 10 bar) doğrudan tanka boşalmasını sağlamalısınız.
Entegre Basınç Düşürücü Valf (/D3)
/D3 seçeneği, entegre bir ZDR 6 basınç düşürücü valf içerir. Pilot kademesinin kararlı, azaltılmış bir basınç (genellikle yaklaşık 40 bar) almasını sağlar, hassas pilot valfini yüksek ve dalgalı ana sistem basınçlarından korur.
Kritik Kurulum Notları
Boşaltma Hattı: Harici pilot boşaltma (Y portu) özel bir hatla doğrudan tanka bağlanmalıdır. Y üzerindeki geri basınç < 10 bar olmalıdır.
Temizlik: Yüksek yağ temizliği sağlayın (ana kademe için önerilen NAS 1638 Sınıf 8 veya ISO 4406 20/18/15).
Pilot Beslemesi: X portuna temiz, regüle edilmiş pilot basıncı sağlayın.