Product Details:
|
| Media Temperature: | -20°C To +80°C (optimal 40–50°C) | Viscosity Range: | 20 To 380 Mm²/s |
|---|---|---|---|
| Electrical Connector: | 7-pin (6 + PE) Plug (DIN EN 175201-804, K31) | Control Signal: | ±10 V DC (Analog Voltage Input, /A1 Suffix) |
| Pilot Oil Supply: | Internal (from P) | ||
| Highlight: | Rexroth hydraulic proportional valve,German hydraulic directional valve,Rexroth valve with warranty |
||
|
Parameter |
Specification |
|---|---|
|
Order Number |
R900700633 |
|
Model |
4WRZE16W8-150-7X/6EG24N9ETK31/A1D3M |
|
Type |
Pilot-operated, 2-stage proportional directional valve |
|
Function |
4/3-way (3 positions, 4 ports), spring-centered |
|
Spool Type |
W8 (Overlap spool, specific transition characteristics) |
|
Nominal Size |
NG16 (CETOP 7) |
|
Max. Operating Pressure |
P, A, B: 350 bar; T port: 210 bar |
|
Rated Flow |
150 L/min (at Δp = 10 bar per control land) |
|
Max. Flow |
Approx. 460 L/min |
|
Electronics |
Integrated On-Board Electronics (OBE) |
|
Supply Voltage |
24V DC (19.4...35 VDC) |
|
Control Signal |
±10 V DC (Analog voltage input, /A1 suffix) |
|
Feedback |
Yes (LVDT, closed-loop spool position) |
|
Pilot Oil Supply |
Internal (from P) |
|
Pilot Oil Return |
External (Y) |
|
Manual Override |
Yes (N9, concealed) |
|
Pressure Reducing Valve |
Yes (D3, ZDR 6 DP0-4X/...) |
|
Seal Material |
NBR |
|
Electrical Connector |
7-pin (6 + PE) plug (DIN EN 175201-804, K31) |
|
Mounting Interface |
ISO 4401-07-07-0-05 (CETOP 7 subplate) |
|
Suitable Media |
Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR |
|
Media Temperature |
-20°C to +80°C (optimal 40–50°C) |
|
Viscosity Range |
20 to 380 mm²/s |
|
Weight |
Approx. 12.6 kg |
![]()
| 4WRZE16E150-72/6EG24TK31/A1M |
| 4WRZE16E3-150-72/6EG24EK31/A1D3M |
| 4WRZE16E3-150-72/6EG24N9TK31/A1M |
| 4WRZE16EA150-72/6EG24ETK31/A1M |
| 4WRZE16EA150-72/6EG24K31/A1D3M |
| 4WRZE16EA150-72/6EG24K31/A1M |
| 4WRZE16EA150-72/6EG24K31/F1V |
| 4WRZE16EA150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16EB150-72/6EG24EK31/A1D3V |
| 4WRZE16W6 150-72/6EG24K31/A1M |
| 4WRZE16W6-100-72/6EG24ETK31/A1D3M |
| 4WRZE16W6-100-72/6EG24ETK31/A1D3V |
| 4WRZE16W6-100-72/6EG24ETK31/F1D3V |
| 4WRZE16W6-100-72/6EG24K31/A1M |
| 4WRZE16W6-100-72/6EG24K31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/A1M |
| 4WRZE16W6-100-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9ETK31/F1D3V |
| 4WRZE16W6-100-72/6EG24N9K31/A1M |
| 4WRZE16W6-100-72/6EG24N9K31/F1D3M |
| 4WRZE16W6-100-72/6EG24N9K31/F1V |
| 4WRZE16W6-100-72/6EG24N9TK31/F1D3M |
| 4WRZE16W6-150-72/6EG24EK31/A1D3M |
| 4WRZE16W6-150-72/6EG24EK31/A1M |
| 4WRZE16W6-150-72/6EG24EK31/A1V |
| 4WRZE16W6-150-72/6EG24EK31/F1D3M |
| 4WRZE16W6-150-72/6EG24ETK31/A1D3M |
| 4WRZE16W6-150-72/6EG24ETK31/A1M |
| 4WRZE16W6-150-72/6EG24ETK31/F1D3M |
| 4WRZE16W6-150-72/6EG24K31/A1D3M |
| 4WRZE16W6-150-72/6EG24K31/A1V |
| 4WRZE16W6-150-72/6EG24K31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1M |
| 4WRZE16W6-150-72/6EG24N9EK31/A1V |
| 4WRZE16W6-150-72/6EG24N9EK31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9EK31/F1D3V |
| 4WRZE16W6-150-72/6EG24N9EK31/F1V |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1D3V |
| 4WRZE16W6-150-72/6EG24N9ETK31/A1M |
| 4WRZE16W6-150-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W6-150-72/6EG24N9K31/A1D3M |
| 4WRZE16W6-150-72/6EG24N9K31/A1M |
| 4WRZE16W6-150-72/6EG24N9K31/A1V |
| 4WRZE16W6-150-72/6EG24N9K31/F1D3V |
| 4WRZE16W6-150-72/6EG24N9K31/F1V |
| 4WRZE16W6-150-72/6EG24N9TK31/A1D3M |
| 4WRZE16W8-100-72/6EG24EK31/F1D3V |
| 4WRZE16W8-100-72/6EG24K31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9EK31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9EK31/A1D3V |
| 4WRZE16W8-100-72/6EG24N9EK31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9ETK31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/A1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/A1M |
| 4WRZE16W8-100-72/6EG24N9K31/A1V |
| 4WRZE16W8-100-72/6EG24N9K31/F1D3M |
| 4WRZE16W8-100-72/6EG24N9K31/F1V |
| 4WRZE16W8-100-72/6EG24N9TK31/F1M |
| 4WRZE16W8-150-72/6EG24EK31/A1M |
| 4WRZE16W8-150-72/6EG24EK31/F1D3M |
| 4WRZE16W8-150-72/6EG24ETK31/A1D3M |
| 4WRZE16W8-150-72/6EG24ETK31/A1M |
| 4WRZE16W8-150-72/6EG24ETK31/F1D3M |
| 4WRZE16W8-150-72/6EG24K31/A1D3M |
| 4WRZE16W8-150-72/6EG24K31/F1M |
| 4WRZE16W8-150-72/6EG24N9EK31/A1D3M |
| 4WRZE16W8-150-72/6EG24N9EK31/A1D3V |
| 4WRZE16W8-150-72/6EG24N9EK31/A1M |
| 4WRZE16W8-150-72/6EG24N9EK31/F1D3M |
| 4WRZE16W8-150-72/6EG24N9EK31/F1D3V |
| 4WRZE16W8-150-72/6EG24N9ETK31/A1D3M |
| 4WRZE16W8-150-72/6EG24N9ETK31/A1M |
| 4WRZE16W8-150-72/6EG24N9ETK31/F1D3V |
| 4WRZE16W8-150-72/6EG24N9ETK31/F1V |
| 4WRZE16W8-150-72/6EG24N9K31/A1D3M |
| 4WRZE16W8-150-72/6EG24N9K31/A1M |
| 4WRZE16W8-150-72/6EG24N9K31/F1D3M |
| 4WRZE16W8-150-72/6EG24N9K31/F1D3V |
| 4WRZE168-150-72/6EG24N9K31/F1V |
| 4WRZE16W8-150-72/6EG24N9TK31/F1D3M |
| 4WRZE16W9-100-72/6EG24N9K31/F1D3M |
| 4WRZE16W9-150-72/6EG24N9EK31/F1D3M |
| 4WRZE25E1-220-72/6EG24ETK31/A1D3M |
| 4WRZE25E1-220-72/6EG24N9EK31/A1D3M |
| 4WRZE25E1-325-72/6EG24ETK31/A1D3M |
| 4WRZE25E1-325-72/6EG24N9EK31/A1D3M |
| 4WRZE25E1-325-72/6EG24N9EK31/A1V |
| 4WRZE25E1-325-72/6EG24N9EK31/F1D3M |
| 4WRZE25E1-325-72/6EG24N9ETK31/A1D3M |
| 4WRZE25E1-325-72/6EG24N9ETK31/A1M |
| 4WRZE25E1-325-72/6EG24N9K31/A1D3M |
| 4WRZE25E1-325-72/6EG24N9K31/F1V |
| 4WRZE25E220-72/6EG24ETK31/A1D3M |
| 4WRZE25E220-72/6EG24K31/A1M |
| 4WRZE25E220-72/6EG24N9EK31/A1D3V |
| 4WRZE25E220-72/6EG24N9EK31/A1M |
| 4WRZE25E220-72/6EG24N9ETK31/F1D3M |
Q: What is the main difference between the W8-spool and the previous W6-spool?
A: The W8-spool has a different overlap and transition characteristic compared to the W6. While both are overlap spools for smooth operation, the W8 typically offers a specific P-A/B and B-T/A transition pattern. Refer to the Rexroth symbol sheet for the exact flow path characteristic.
Q: What does the /A1D3M suffix mean?
A: The /A1 suffix indicates ±10 V DC voltage control input. The /D3 suffix indicates an integrated pressure reducing valve (ZDR 6) for regulating pilot pressure. The /M suffix specifies standard NBR seals.
Q: How does the pilot oil configuration work?
A: This valve (/6EG24N9ETK31) uses internal pilot oil supply (from main P port) but requires an external pilot oil return (Y port). This is different from the "ET" configuration (internal drain to T) and requires you to connect the Y port directly to the tank with minimal backpressure (max 30 bar).
Q: Why choose this specific configuration?
A: This model is ideal for applications requiring smooth control (W8 spool) with the simplicity of internal pilot supply. The ±10 V control (/A1) is common for PLC analog outputs. The integrated /D3 pressure reducer protects the pilot stage from system pressure fluctuations.
Q: What is the critical installation note?
A: You must connect the external pilot drain (Y port) directly to the tank with a dedicated line. Backpressure on the Y port must be below 30 bar to ensure proper pilot valve function. The main T-port backpressure must be below 210 bar. Maintain high oil cleanliness (recommended NAS 1638 Class 8 or better for the main stage).