logo
Home ProductsRexroth Hydraulic Pump

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

I'm Online Chat Now

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

Large Image :  PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

Product Details:
Place of Origin: Germany
Brand Name: Rexroth
Certification: ISO
Model Number: PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

Description
Basic Configuration: Displacement Step Adjustment Increment Pressure Control: Pressure Compensation Hysteresis Value
Highlight:

Rexroth vane pump PV7 series

,

Pilot operated vane pump Germany

,

Imported Rexroth PV7 hydraulic pump

Rexroth PV7 Series Vane Pumps
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16

Pilot operated Rexroth vane pump PV7 series imported from Germany

Technical Specifications
Parameter/Property Category Direct-Acting (PV7-A) Series Pilot-Operated (PV7-C/D/N/W) Series Unit Remarks
Model Range PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 #VALUE! 1X/2X=component series; 06/14/20=frame size
Displacement per Revolution 10-25 14-150 cm³/rev Displacement varies by specific model suffix
Max. Continuous Working Pressure 100 160 bar PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar
Max. Peak Pressure 120 200 bar Short-term (≤5s) overload only
Speed Range 600-2800 600-3600 rpm Higher speed for smaller displacement models
Max. Flow Rate (at 1800 rpm) 36 270 l/min Calculated at rated displacement
Volumetric Efficiency (Rated Condition) ≥90% ≥92% % At 160 bar, 1800 rpm, ISO VG 46 oil
Total Efficiency (Nominal Operation) ≥80% ≥82% % Includes mechanical & volumetric efficiency
Suction Pressure Range 1 -0.8 to +1 bar Absolute pressure: 0.2-1.1 bar
Fluid Compatibility Mineral oil (HLP), synthetic oil (HETG/HEES) Mineral oil (HLP), synthetic oil (HETG/HEES) - Use FKM seals for synthetic fluids
Fluid Viscosity Range 10-1000 (operation); 2-1500 (start-up) 10-1000 (operation); 2-1500 (start-up) mm²/s Optimal: 16-160 mm²/s
Fluid Temperature Range -20 to +80 -20 to +80 °C Storage: -40 to +90 °C
Noise Level (1 m Distance, Rated Operation) ≤63 ≤65 dB(A) Pilot-operated models have optimized noise reduction
Mounting Standard ISO 3019-2 flange ISO 3019-2 flange - Optional foot mounting for some models
Shaft Connection ISO 4162 splined shaft ISO 4162 splined shaft - Keyed shaft available on request
Seal Material NBR (standard); FKM (optional) NBR (standard); FKM (optional) - NBR for mineral oil; FKM for synthetic oil
PV7-1X/63-
<div class=Available Models
PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
PV7-1X/16-20RE01MC0-16-P120
PV7-1X/100-150RE07MW0-08WH
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
Technical FAQs
Q: What is the recommended range for the Standby Pressure Trigger Threshold?
A: Set it to 20-50% of the rated working pressure to activate low-power standby mode efficiently.
Q: Can the Maximum Working Pressure Dynamic Limit exceed the pump's rated pressure?
A: No, this limit must never exceed the rated pressure specified in the Rexroth PV7 Technical Manual.
Q: How does adjusting the Pressure Relief Response Delay help the system?
A: A longer delay suppresses hydraulic shock and pressure surges, ensuring smoother system operation.
Q: What happens if the Pressure Compensation Hysteresis Value is set too low?
A: The pressure control system will become overly sensitive, leading to frequent pressure fluctuations.
Q: When will the Low-Pressure Leakage Alarm Threshold trigger an alert?
A: It triggers an alarm when the system pressure drops below the threshold during long-term idle operation, indicating potential leakage.
Flow Regulation

Advanced flow regulation capabilities for precise hydraulic system control.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)