logo
Casa ProdottiPompa idraulica Rexroth

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pompa a pale Rexroth pilota della serie PV7 importata dalla Germania

Sono ora online in chat

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pompa a pale Rexroth pilota della serie PV7 importata dalla Germania

PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH	
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

Grande immagine :  PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pompa a pale Rexroth pilota della serie PV7 importata dalla Germania

Dettagli:
Luogo di origine: Germania
Marca: Rexroth
Certificazione: ISO
Numero di modello: PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Imballaggi particolari: Scatola di legno
Tempi di consegna: 2 settimane
Termini di pagamento: MoneyGram, Western Union, T/T, D/P, D/A, L/C
Capacità di alimentazione: 100

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pompa a pale Rexroth pilota della serie PV7 importata dalla Germania

descrizione
Configurazione di base: Incremento della regolazione del passo di spostamento Controllo della pressione: Valore di isteresi di compensazione della pressione
Evidenziare:

Pompa a vele Rexroth serie PV7

,

Pompa a pale pilotata Germania

,

Pompa idraulica Rexroth PV7 importata

Pompe a palette serie PV7 Rexroth
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16

Pompa a palette Rexroth serie PV7 a comando pilota importata dalla Germania

Specifiche tecniche
Categoria Parametro/Proprietà Serie ad azione diretta (PV7-A) Serie a comando pilota (PV7-C/D/N/W) Unità Osservazioni
Gamma modelli PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 #VALUE! 1X/2X=serie componenti; 06/14/20=dimensione telaio
Cilindrata per rivoluzione 10-25 14-150 cm³/rev La cilindrata varia in base al suffisso specifico del modello
Pressione di esercizio continua massima 100 160 bar PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar
Pressione di picco massima 120 200 bar Sovraccarico a breve termine (≤5s) solo
Gamma di velocità 600-2800 600-3600 rpm Velocità più elevata per modelli con cilindrata minore
Portata massima (a 1800 rpm) 36 270 l/min Calcolato alla cilindrata nominale
Efficienza volumetrica (condizione nominale) ≥90% ≥92% % A 160 bar, 1800 rpm, olio ISO VG 46
Efficienza totale (funzionamento nominale) ≥80% ≥82% % Include l'efficienza meccanica e volumetrica
Gamma di pressione di aspirazione 1 -0.8 to +1 bar Pressione assoluta: 0.2-1.1 bar
Compatibilità dei fluidi Olio minerale (HLP), olio sintetico (HETG/HEES) Olio minerale (HLP), olio sintetico (HETG/HEES) - Utilizzare guarnizioni FKM per fluidi sintetici
Gamma di viscosità del fluido 10-1000 (funzionamento); 2-1500 (avvio) 10-1000 (funzionamento); 2-1500 (avvio) mm²/s Ottimale: 16-160 mm²/s
Gamma di temperatura del fluido -20 to +80 -20 to +80 °C Stoccaggio: -40 to +90 °C
Livello di rumore (distanza di 1 m, funzionamento nominale) ≤63 ≤65 dB(A) I modelli a comando pilota hanno una riduzione del rumore ottimizzata
Standard di montaggio Flangia ISO 3019-2 Flangia ISO 3019-2 - Montaggio a piede opzionale per alcuni modelli
Collegamento albero Albero scanalato ISO 4162 Albero scanalato ISO 4162 - Albero con chiavetta disponibile su richiesta
Materiale della guarnizione NBR (standard); FKM (opzionale) NBR (standard); FKM (opzionale) - NBR per olio minerale; FKM per olio sintetico
PV7-1X/63-
<div class=Modelli disponibili
PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
PV7-1X/16-20RE01MC0-16-P120
PV7-1X/100-150RE07MW0-08WH
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
FAQ tecnico
D: Qual è l'intervallo consigliato per la soglia di attivazione della pressione di standby?
R: Impostalo al 20-50% della pressione di esercizio nominale per attivare in modo efficiente la modalità standby a basso consumo.
D: Il limite dinamico della pressione di esercizio massima può superare la pressione nominale della pompa?
R: No, questo limite non deve mai superare la pressione nominale specificata nel manuale tecnico Rexroth PV7.
D: In che modo la regolazione del ritardo di risposta dello scarico della pressione aiuta il sistema?
R: Un ritardo più lungo sopprime gli urti idraulici e le sovratensioni di pressione, garantendo un funzionamento più fluido del sistema.
D: Cosa succede se il valore di isteresi della compensazione della pressione è impostato troppo basso?
R: Il sistema di controllo della pressione diventerà eccessivamente sensibile, portando a frequenti fluttuazioni di pressione.
D: Quando la soglia di allarme di perdita a bassa pressione attiverà un avviso?
R: Attiva un allarme quando la pressione del sistema scende al di sotto della soglia durante il funzionamento a riposo a lungo termine, indicando una potenziale perdita.
Regolazione del flusso

Funzionalità avanzate di regolazione del flusso per un controllo preciso del sistema idraulico.

Dettagli di contatto
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Persona di contatto: Mr. liyun

Telefono: +8615280488899

Invia la tua richiesta direttamente a noi (0 / 3000)