Detail produk:
|
| Nomor Pesanan: | 0811402080 | Model: | DREBE6X-1X/175MG24K31A1M |
|---|---|---|---|
| Maks. Tekanan Operasi: | Port P (Inlet): 315 bar Port A (Outlet Dikurangi): 175 bar Port T (Tank): 250 bar | Rentang Tekanan yang Dapat Disesuaikan: | 0 – 175 bar (sebanding secara elektrik) |
| Maks. Kapasitas Aliran: | 40 liter/menit |
|
Parameter |
Spesifikasi |
|---|---|
|
Nomor Pesanan |
0811402080 |
|
Model |
DREBE6X-1X/175MG24K31A1M |
|
Jenis |
Dioperasikan dengan pilotkatup pengurang tekanan 3 arah proporsional |
|
Fungsi |
Kurangi tekanan masuk (P) ke tekanan sekunder terkontrol (A); aliran berlebih ke tangki (T) |
|
Ukuran Nominal |
NG6 (CETOP 3, Ukuran 6) |
|
Maks. Tekanan Operasi |
Port P (saluran masuk):315 batang |
|
Rentang Tekanan yang Dapat Disesuaikan |
0 – 175 bilah(sebanding secara elektrik) |
|
Maks. Kapasitas Aliran |
40 liter/menit |
|
Konsumsi Aliran Percontohan |
Kira-kira.0,6 liter/menit (pasokan percontohan internal) |
|
Desain Katup |
Katup spul yang dioperasikan pilot,dengan elektronik terintegrasi (OBE) |
|
Tegangan Pasokan |
24VDC (G24) |
|
Sinyal Kontrol |
0 – +10 V(A1) |
|
Konektor Listrik |
6-pin + PE (K31)per DIN 43563 (termasuk konektor, soket terpisah) |
|
Fitur Khusus |
Umpan balik posisi (loop tertutup), Elektronik terintegrasi (OBE), Tanpa katup periksa (M) |
|
Antarmuka Pemasangan |
ISO 4401-03-02-0-05(Pelat bawah NG6) |
|
Bahan Segel |
NBR (L) |
|
Media yang Cocok |
Minyak mineral (HL, HLP), HLP-D, HVLP, cairan HFC |
|
Suhu Media |
-20°C hingga +80°C |
|
Kisaran Viskositas |
10 – 800 mm²/dtk (disarankan 30–46 mm²/dtk) |
|
Suhu Sekitar |
-20°C hingga +50°C (elektronik) |
|
Persyaratan Kebersihan |
ISO 440620/18/15atau lebih baik |
|
Kontrol Kinerja |
Histeresis ≤±1 %, Ulangi akurasi <±2 % |
|
Berat |
Kira-kira.2,4kg |
![]()
| R901307054 ZDREE6VP1-1X/50MG24K24F1M |
| R901348916 ZDREE6VP1-1X/50MG24N9K24A1M |
| R901442471 ZDREE6VP1-1X/50MG24N9K24A1V |
| R901333123 ZDREE6VP2-1X/100MG24K24A1M |
| R901361034 ZDREE6VP2-1X/100MG24K24A1V |
| R901335265 ZDREE6VP2-1X/100MG24K24F1M |
| R901423690 ZDREE6VP2-1X/100MG24N9K24A1M |
| R901426844 ZDREE6VP2-1X/100MG24N9K24F1M |
| R901412854 ZDREE6VP2-1X/100MG24N9K24F1V |
| R901319105 ZDREE6VP2-1X/210MG24K24A1M |
| R901344604 ZDREE6VP2-1X/210MG24K24F1M |
| R901364868 ZDREE6VP2-1X/210MG24K24F1V |
| R901358797 ZDREE6VP2-1X/210MG24N9K24A1M |
| R901366629 ZDREE6VP2-1X/210MG24N9K24F1M |
| R901427678 ZDREE6VP2-1X/210MG24N9K24F1V |
| R901359129 ZDREE6VP2-1X/315MG24K24A1M |
| R901359130 ZDREE6VP2-1X/315MG24K24F1M |
| R901361520 ZDREE6VP2-1X/315MG24N9K24A1M |
| R901427111 ZDREE6VP2-1X/315MG24N9K24F1M |
| R901335844 ZDREE6VP2-1X/50MG24K24A1M |
| R901387239 ZDREE6VP2-1X/50MG24K24A1M-1 |
| R901414672 ZDREE6VP2-1X/50MG24N9K24A1M |
| R901445816 ZDREE6VP2-1X/50MG24N9K24F1M |
| R901387981 ZDREE6VP3-1X/100MG24K24A1M |
| R901389298 ZDREE6VP3-1X/100MG24K24F1V |
| R901426503 ZDREE6VP3-1X/100MG24N9K24F1M |
| R901339813 ZDREE6VP3-1X/210MG24K24A1M |
| R901426504 ZDREE6VP3-1X/210MG24K24F1M |
| R901432627 ZDREE6VP3-1X/210MG24N9K24F1M |
| R901336443 ZDREE6VP3-1X/50MG24K24A1M |
| R901332583 ZDREE6VP3-1X/50MG24K24F1M |
| R901346257 ZDREE6VP3-1X/50MG24K24F1V |
| R901333120 ZDREE6VP4-1X/100MG24K24A1M |
| R901342612 ZDREE6VP4-1X/100MG24K24F1M |
| R901419420 ZDREE6VP4-1X/100MG24K24F1V |
| R901344934 ZDREE6VP4-1X/210MG24K24A1M |
| R901434069 ZDREE6VP4-1X/210MG24K24F1M |
| R901343769 ZDREE6VP4-1X/210MG24K24F1V |
| R901358800 ZDREE6VP4-1X/210MG24N9K24A1M |
| R901366630 ZDREE6VP4-1X/210MG24N9K24F1M |
| R901374071 ZDREE6VP4-1X/210MG24N9K24F1V |
| R901404475 ZDREE6VP4-1X/315MG24K24F1M |
| R901437499 ZDREE6VP4-1X/315MG24N9K24F1M |
| R901410698 ZDREE6VP4-1X/50MG24K24A1M |
| 力士乐REXROTH先导式比例减压阀ZDRE 10, ZDREE 10 |
| R901219741 ZDRE10VP2-2X/100LMG24K4M |
| R901241817 ZDRE10VP2-2X/100LMG24K4V |
| R901215393 ZDRE10VP2-2X/100XLMG24K4M |
| R901241816 ZDRE10VP2-2X/100XLMG24K4V |
| R901283725 ZDRE10VP2-2X/100XYMG24K4M |
| R901308768 ZDRE10VP2-2X/100XYMG24K4V |
| R901160006 ZDRE10VP2-2X/100YMG24K4M |
| R901273232 ZDRE10VP2-2X/200LMG24K4M |
| R901227551 ZDRE10VP2-2X/200XLMG24K4M |
| R901220758 ZDRE10VP2-2X/200XLMG24K4V |
| R901247462 ZDRE10VP2-2X/200XYMG24K4M |
| R901160004 ZDRE10VP2-2X/200YMG24K4M |
| R901262400 ZDRE10VP2-2X/200YMG24K4V |
| R901254861 ZDRE10VP2-2X/315LMG24K4M |
| R901251520 ZDRE10VP2-2X/315XLMG24K4M |
| R901213578 ZDRE10VP2-2X/315XLMG24K4V |
| R901324287 ZDRE10VP2-2X/315XYMG24K4M |
| R901160008 ZDRE10VP2-2X/315YMG24K4M |
| R901426460 ZDRE10VP2-2X/315YMG24K4V |
| R901251082 ZDRE10VP2-2X/50XLMG24K4M |
| R901337570 ZDRE10VP2-2X/50XLMG24K4V |
| R901291142 ZDRE10VP2-2X/50XYMG24K4M |
| R901160011 ZDRE10VP2-2X/50YMG24K4M |
| R901236347 ZDRE10VP2-2X=315XLMG24K4M |
| 0811402165 ZDRE10VP2X-1X/180LG24-25Z4M-8 |
Pertanyaan Umum:
Elektronik Terintegrasi (OBE) & Loop Tertutup
Itu"E" diDREBEmenegaskanElektronik On-Board (OBE). Ini berarti katup berisi amplifier dan sensor umpan balik posisinya sendiri. Anda menyediakanDaya 24VDCdan sebuahsinyal perintah 0–10 Vlangsung ke katupkonektor K31. Desain loop tertutup ini memberikan akurasi tinggi (histeresis ≤1%) dan menghilangkan kebutuhan akan amplifier VT-5000 eksternal.
Peringkat Tekanan Berkurang Tinggi (175 bar)
Itu"175"menunjukkanpengurangan tekanan maksimum yang dapat disesuaikan secara elektrik di port A. Ini adalah varian kelas menengah, cocok untuk aplikasi yang memerlukan tekanan sekunder lebih tinggi daripada versi 75 bar namun lebih rendah dari varian 310 bar.
Logika Pengurangan Tekanan 3 Arah
Katup ini beroperasi sebagai aPerangkat 3 port (P, A, T). Ini secara terus menerus membandingkan tekanan A-port dengan setpoint listrik. Jika tekanan beban di A mencoba melebihi setpoint (misalnya, karena beban yang berlebihan), katup membuka jalur A→T untuk "membuang" kelebihan tekanan dan mempertahankan regulasi.
Tanpa Katup Periksa (M)
Itu"M" di akhiran menunjukkantidak ada katup periksadisertakan. Ini berarti aliran dari port A kembali ke port P diblokir oleh desain spool, namun tidak ada jalur aliran balik bebas. Untuk aplikasi yang memerlukan aliran balik bebas, diperlukan varian yang berbeda.
Catatan Instalasi Penting
Koneksi Sinyal Langsung: Hubungkan sinyal 24V DC dan 0–10 V langsung ke konektor K31. Jangan gunakan amplifier eksternal.
Tekanan Balik Saluran Tangki: Port T harus terhubung ke tangki dengantekanan balik minimal. Tekanan balik yang tinggi di T akan ditambahkan ke tekanan port A, menyebabkan regulasi tidak akurat (P_A_efektif = P_set + P_T_backpressure).
Aliran Percontohan: Katup menggunakan suplai pilot internal (kira-kira 0,6 L/mnt), sehingga tidak diperlukan jalur pilot eksternal, namun pastikan aliran pompa Anda memperhitungkan konsumsi konstan ini.
Kontak Person: Mr. liyun
Tel: +8615280488899