logo
Rumah ProdukKatup hidraulik Rexroth

0811402055 DRE6X-1X/175MG24-8NZ4M katup pengurangan tekanan proporsional dari Rexroth, Jerman

I 'm Online Chat Now

0811402055 DRE6X-1X/175MG24-8NZ4M katup pengurangan tekanan proporsional dari Rexroth, Jerman

0811402055 DRE6X-1X/175MG24-8NZ4M Proportional pressure reducing valve from Rexroth, Germany
0811402055 DRE6X-1X/175MG24-8NZ4M Proportional pressure reducing valve from Rexroth, Germany

Gambar besar :  0811402055 DRE6X-1X/175MG24-8NZ4M katup pengurangan tekanan proporsional dari Rexroth, Jerman

Detail produk:
Tempat asal: Jerman
Nama merek: Rexroth
Sertifikasi: ISO
Nomor model: 0811402055 DRE6X-1X/175MG24-8NZ4M
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1
Kemasan rincian: kotak kayu
Waktu pengiriman: 2 minggu
Syarat-syarat pembayaran: Western Union,T/T,D/P,D/A,L/C
Menyediakan kemampuan: 100

0811402055 DRE6X-1X/175MG24-8NZ4M katup pengurangan tekanan proporsional dari Rexroth, Jerman

Deskripsi
Berat: 2,5 – 3kg Kontrol Kinerja: Histeresis ≤ ±2,5 %, Akurasi pengulangan < ±2 %​
Suhu Media: -20°C hingga +80°C​ Konsumsi Aliran Percontohan: Kira-kira. 0,65 L/mnt​ (pasokan pilot internal)
Maks. Kapasitas Aliran: 30 – 40 L/mnt​ (khas untuk NG6)

Parameter

Spesifikasi

Nomor pesananAku tidak tahu.

0811402055Aku tidak tahu.

ModelAku tidak tahu.

DRE6X-1X/175MG24-8NZ4M

JenisAku tidak tahu.

Dioperasikan oleh pilotkatup pengurangan tekanan proporsional 3 arah

FungsiAku tidak tahu.

Kurangi tekanan masuk (P) ke tekanan sekunder terkontrol (A); aliran berlebihan ke tangki (T)

Ukuran NominalAku tidak tahu.

NG6(CETOP 3, Ukuran 6)

Maks. Tekanan operasiAku tidak tahu.

Pelabuhan P (Inlet):315 bar
Pelabuhan A (Pengeluaran Rendah):175 bar
Pelabuhan T (Tank):250 barAku tidak tahu.

Jangkauan Tekanan yang Bisa DisesuaikanAku tidak tahu.

0 175 bar(secara listrik proporsional)

Kapasitas aliran maksimumAku tidak tahu.

30 L/menit(tipikal untuk NG6)

Konsumsi Aliran PilotAku tidak tahu.

Sekitar.00,65 L/menit(suplai pilot internal)

Desain KatupAku tidak tahu.

klep spool yang dioperasikan pilot,membutuhkan penguat eksternalAku tidak tahu.

Solenoid CoilAku tidak tahu.

Solenoid proporsional,24V DC(G24), arus maksimum0.8 AAku tidak tahu.

Sinyal kontrolAku tidak tahu.

Membutuhkan elektronik pemicu eksternal (misalnya, VT-5000) untuk 010 V atau 420 mA

Konektor ListrikAku tidak tahu.

Konektor perangkat 3 pin (Z4)menurut EN 175301-803 (termasuk)

Fitur KhususAku tidak tahu.

Penolakan manual (N); Tidak ada katup kontrol (M)

Antarmuka PemasanganAku tidak tahu.

ISO 4401-03-02-0-05 / 0-94(Subplat NG6)

Bahan segelAku tidak tahu.

NBR(M)

Media yang CocokAku tidak tahu.

Minyak mineral (HL, HLP), HLP-D, HVLP, cairan HFC

Suhu mediaAku tidak tahu.

-20°C sampai +80°CAku tidak tahu.

Kisaran viskositasAku tidak tahu.

15 380 mm2/s (disarankan 3046 mm2/s)

Suhu LingkunganAku tidak tahu.

-20°C sampai +70°C

Persyaratan KebersihanAku tidak tahu.

ISO 440620/18/15atau lebih baik

Kinerja KontrolAku tidak tahu.

Hysteresis ≤±2,5%, Ulangi akurasi <± 2 %Aku tidak tahu.

Berat badanAku tidak tahu.

Sekitar.2.5 3 kgAku tidak tahu.

0811402055 DRE6X-1X/175MG24-8NZ4M katup pengurangan tekanan proporsional dari Rexroth, Jerman 0

R900247619 ZDRE6VP2-1X/100MG24NK4V
R900535118 ZDRE6VP2-1X/100MG24NZ4M
R900926935 ZDRE6VP2-1X/100MG24NZ4V
R900528575 ZDRE6VP2-1X/100MG24Z4M
R900532494 ZDRE6VP2-1X/100MG24Z4M-1
R900529331 ZDRE6VP2-1X/100MG24Z4V
R900915963 ZDRE6VP2-1X/210MG24K4M
R900729095 ZDRE6VP2-1X/210MG24K4V
R901252630 ZDRE6VP2-1X/210MG24N9K4M
R901252631 ZDRE6VP2-1X/210MG24N9K4V
R900915962 ZDRE6VP2-1X/210MG24NK4M
R900947020 ZDRE6VP2-1X/210MG24NK4V
R900538641 ZDRE6VP2-1X/210MG24NZ4M
R900536904 ZDRE6VP2-1X/210MG24NZ4V
R900523671 ZDRE6VP2-1X/210MG24Z4M
R900570793 ZDRE6VP2-1X/210MG24Z4V
R900573435 ZDRE6VP2-1X/315MG24NK4M
R900954431 ZDRE6VP2-1X/50MG24K4M
R901005655 ZDRE6VP2-1X/50MG24K4V
R901252632 ZDRE6VP2-1X/50MG24N9K4M
R900947833 ZDRE6VP2-1X/50MG24NK4M
R900535517 ZDRE6VP2-1X/50MG24NZ4M
R900534431 ZDRE6VP2-1X/50MG24Z4M
R900961147 ZDRE6VP3-1X/100MG24K4M
R901186845 ZDRE6VP3-1X/100MG24K4V
R901252633 ZDRE6VP3-1X/100MG24N9K4M
R900915964 ZDRE6VP3-1X/100MG24NK4M
R900562790 ZDRE6VP3-1X/100MG24NZ4M
R900539403 ZDRE6VP3-1X/100MG24Z4M
R900536116 ZDRE6VP3-1X/100MG24Z4M-1
R900935013 ZDRE6VP3-1X/210MG24K4M
R901252634 ZDRE6VP3-1X/210MG24N9K4M
R900948838 ZDRE6VP3-1X/210MG24NK4M
R900567421 ZDRE6VP3-1X/210MG24NZ4M
R900532114 ZDRE6VP3-1X/210MG24Z4M
R901055131 ZDRE6VP3-1X/50MG24K4M
R901252635 ZDRE6VP3-1X/50MG24N9K4M
R900915965 ZDRE6VP3-1X/50MG24NK4M
R900534916 ZDRE6VP3-1X/50MG24NZ4M
R900952608 ZDRE6VP4-1X/100MG24K4M
R901218814 ZDRE6VP4-1X/100MG24K4V
R901252636 ZDRE6VP4-1X/100MG24N9K4M
R900926157 ZDRE6VP4-1X/100MG24NK4M
R900907002 ZDRE6VP4-1X/100MG24NZ4M
R900562028 ZDRE6VP4-1X/100MG24Z4M
R900915966 ZDRE6VP4-1X/210MG24K4M
R901390586 ZDRE6VP4-1X/210MG24K4V
R901252637 ZDRE6VP4-1X/210MG24N9K4M
R901252638 ZDRE6VP4-1X/210MG24N9K4V
R900961333 ZDRE6VP4-1X/210MG24NK4M
R901065854 ZDRE6VP4-1X/210MG24NK4V
R900926269 ZDRE6VP4-1X/210MG24NZ4M
R900915628 ZDRE6VP4-1X/210MG24NZ4V
R900526714 ZDRE6VP4-1X/210MG24Z4M
R900975409 ZDRE6VP4-1X/50MG24K4M
R901005637 ZDRE6VP4-1X/50MG24K4V
R901252639 ZDRE6VP4-1X/50MG24N9K4M
R900915968 ZDRE6VP4-1X/50MG24NK4M
R900535518 ZDRE6VP4-1X/50MG24NZ4M
R901252640 ZDRE6VP4-1X=100MG24N9K4M=LB
R900968464 ZDRE6VP4-1X=100MG24NK4M=LB
0811402182 ZDRE6VP1X-1X/180G24-25Z4M
0811402183 ZDRE6VP1X-1X/180YG24-25Z4M
0811402184 ZDRE6VP1X-1X/80G24-25Z4M
R901307055 ZDREE6VP1-1X/100MG24K24A1M
R901372402 ZDREE6VP1-1X/100MG24K24A1V
R901383134 ZDREE6VP1-1X/100MG24N9K24F1M
R901336591 ZDREE6VP1-1X/210MG24K24A1M
R901370586 ZDREE6VP1-1X/210MG24K24A1V
R901307056 ZDREE6VP1-1X/210MG24K24F1M
R901351755 ZDREE6VP1-1X/210MG24N9K24A1M
R901362817 ZDREE6VP1-1X/210MG24N9K24F1M
R901395753 ZDREE6VP1-1X/315MG24K24A1M
R901415122 ZDREE6VP1-1X/50MG24K24A1M

FAQ:

  1. Elektronik eksternal diperlukan (bukan OBE)

    Berbeda dengan seri DREE,DRE6Xkleptidak memiliki elektronik terintegrasi (OBE)Hal ini membutuhkanamplifier proporsional eksternal(misalnya, seri Rexroth VT-5000 atau kartu elektronik pemicu) untuk mengkonversi sinyal perintah 010 V atau 420 mA ke arus kumparan."8"dalam kode menunjukkan nilai arus khusus kumparan (0,8 A).

  2. Tekanan rendah tinggi (175 bar)

    Peraturan175berartiTekanan rendah maksimum yang dapat diatur secara listrikdi port A. Ini adalah varian rentang menengah, cocok untuk aplikasi yang membutuhkan tekanan sekunder yang lebih tinggi daripada versi 100 bar tetapi lebih rendah dari varian 210/310 bar.

  3. Fitur Penolakan Manual (N)

    Peraturan"N"pada akhiran menunjukkan katup dilengkapi denganPenolakan darurat manual(operator manual) Hal ini memungkinkan Anda untuk secara mekanis mengaktifkan katup untuk pengujian atau bantuan tekanan darurat bahkan tanpa tenaga listrik.

  4. Logika Pengurangan Tekanan 3 Cara

    Katup ini bekerja sebagaiPerangkat 3-port(P, A, T). terus membandingkan tekanan A-port dengan titik pengaturan listrik. Jika tekanan beban di A mencoba melebihi titik pengaturan (misalnya, karena beban yang berlebihan),katup membuka jalur A→T untuk "menjatuhkan" tekanan berlebih dan mempertahankan regulasi.

  5. Catatan Instalasi Kritis

    • Amplifier Wajib:Anda harus menyediakan amplifier eksternal. konektor Z4 pada katup hanya membawa kekuatan kumparan dari amplifier.

    • Tekanan balik saluran tangki:Port T harus terhubung ke tangki denganTekanan balik minimalTekanan balik tinggi di T akan ditambahkan ke tekanan A-port, menyebabkan regulasi yang tidak akurat (P_A_efektif = P_set + P_T_backpressure).

    • Aliran Pilot:Katup menggunakan pasokan pilot internal (sekitar 0,65 L/menit), sehingga tidak ada saluran pilot eksternal yang diperlukan, tetapi pastikan aliran pompa Anda menyumbang konsumsi konstan ini.

Rincian kontak
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Kontak Person: Mr. liyun

Tel: +8615280488899

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)