Thông tin chi tiết sản phẩm:
|
| Mã sản phẩm của nhà sản xuất: | R983030771 | Loại van: | Van định hướng bằng tay (Hoạt động trực tiếp) |
|---|---|---|---|
| Chuỗi/Nền tảng: | Dòng WMM, Kích thước NG10 (CETOP 5), Dòng Thành phần 3X | Loại ống chỉ: | Loại D (Xác định mô hình luồng vị trí trung tâm) |
| Tối đa. Áp suất vận hành: | 315 bar (Cổng P, A, B) | ||
| Làm nổi bật: | Rexroth manual directional valve,Rexroth hydraulic valve Germany,4WMM10D3X directional valve |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer Part No. |
R983030771 |
|
Valve Type |
Manual Directional Spool Valve (Direct-Acting) |
|
Series / Platform |
WMM Series, Size NG10 (CETOP 5), Component Series 3X |
|
Spool Type |
D-Type (Defines center position flow pattern) |
|
Max. Operating Pressure |
315 bar (Ports P, A, B) |
|
Max. Flow Rate |
120 L/min (Recommended for standard pressure drop) |
|
Port Connection |
NG10 Interface (ISO 4401-05-04-0-05 / DIN 24340 Form A) |
|
Mounting |
Subplate Mounting (Base plate ordered separately) |
|
Actuation |
Manual Lever (Spring-Centered, no detent) |
|
Sealing Material |
NBR (Standard for mineral oils) |
|
Weight |
Approx. 3.6 kg |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HFC, HFD, HETG, HEES |
|
Viscosity Range |
2.8 - 500 mm²/s (Optimal: 20 - 100 mm²/s) |
|
Fluid Cleanliness |
ISO 4406 Class 20/18/15 (Recommended: Cleaner) |
![]()
| R900924283 4WREE6W08-2X/G24K31/F1V |
| R900929827 4WREE6W1-08-2X/G24K31/A1V |
| R901003235 4WREE6W1-08-2X/G24K31/A1V-280 |
| R901354749 4WREE6W1-08-2X/G24K31/F1M |
| R900965071 4WREE6W1-08-2X/G24K31/F1V |
| R901394157 4WREE6W1-16-2X/G24K31/A1M |
| R900939627 4WREE6W1-16-2X/G24K31/A1V |
| R901154928 4WREE6W1-16-2X/G24K31/A1V-280 |
| R901421940 4WREE6W1-16-2X/G24K31/F1M |
| R900937065 4WREE6W1-16-2X/G24K31/F1V |
| R901368371 4WREE6W1-32-2X/G24K31/A1M |
| R900913359 4WREE6W1-32-2X/G24K31/A1V |
| R901362947 4WREE6W1-32-2X/G24K31/A1V-660 |
| R901354752 4WREE6W1-32-2X/G24K31/F1M |
| R900933476 4WREE6W1-32-2X/G24K31/F1V |
| R900925657 4WREE6W16-2X/G24K31/A1V |
| R901048039 4WREE6W16-2X/G24K31/A1V=LB |
| R901362073 4WREE6W16-2X/G24K31/F1M |
| R900950416 4WREE6W16-2X/G24K31/F1V |
| R900929205 4WREE6W2-32-2X/G24K31/A1V |
| R900911004 4WREE6W32-2X/G24K31/A1V |
| R978902911 4WREE6W32-2X/G24K31/A1VSO43A-1539 |
| R900969483 4WREE6W32-2X/G24K31/A1V=DE |
| R900938299 4WREE6W32-2X/G24K31/A1V=LB |
| R901438225 4WREE6W32-2X/G24K31/A1V=PL |
| R901354753 4WREE6W32-2X/G24K31/F1M |
| R900246793 4WREE6W32-2X/G24K31/F1V |
| R901355277 4WREE6W32-2X=G24K31/A1V |
| R900761481 4WREE6W9-16-2X/G24K31/A1V |
| R900783449 4WREE6W9-32-2X/G24K31/A1V |
| R901185980 4WREE6WA04-2X/G24K31/F1V |
| R900973482 4WREE6WA08-2X/G24K31/A1V |
| R901180378 4WREE6WA08-2X/G24K31/F1V |
| R900974247 4WREE6WA16-2X/G24K31/A1V |
| R900617766 4WREE6WA16-2X/G24K31/F1V |
| R900926997 4WREE6WA32-2X/G24K31/A1V |
| R900964934 4WREE6WA32-2X/G24K31/F1V |
| R900780141 4WREE6WB32-2X/G24K31/A1V |
| R978907329 4WREE10E50-2X/G24K31/A1VSO43A-1595 |
| R978900573 4WREE10V75-2X/G24K31/A1VSO43A-1505 |
| R987373453 4WREE10V75-2X/G24K31/A1V-S047-906 |
| R978902912 4WREE10W75-2X/G24K31/A1VSO43A-1547 |
| R978919605 4WREE10W75-2X/G24K31/A1VSO43A-1733 |
| R978014651 4WREE6V08-2X/G24K31/F1VSO43A-1485 |
| R978008628 4WREE6V08-2X/G24K31/F1VSO43A-1639 |
| R978915950 4WREE6V16-2X/G24K31/A1VSO43A-1639 |
| R978917001 4WREE6V16-2X/G24K31/F1VSO43A-1639 |
| R978899985 4WREE6V32-2X/G24K31/A1VSO43A-1485 |
| R978912989 4WREE6V32-2X/G24K31/F1VSO43A-1639 |
| R901395707 4WREEM10E1-25-2X/G24K34/B6V |
| R900787894 4WREEM10E1-50-2X/G24K34/B6V |
| R901090746 4WREEM10E1-75-2X/G24K34/B6V |
| R901246417 4WREEM10E1-75-2X=G24K34/B6V |
| R900727833 4WREEM10E25-2X/G24K34/B6V |
| R900246856 4WREEM10E50-2X/G24K34/B6V |
| R900246617 4WREEM10E75-2X/G24K34/B6V |
| R901084068 4WREEM10R3-75-2X/G24K34/B6V |
| R901030889 4WREEM10W1-50-2X/G24K34/B6V |
| R901083029 4WREEM10W1-75-2X/G24K34/B6V |
| R901199059 4WREEM10W25-2X/G24K34/B6V |
| R901326891 4WREEM10W50-2X/G24K34/B6V |
| R901008707 4WREEM10W75-2X/G24K34/B6V |
| R900778356 4WREEM6E04-2X/G24K34/B6V |
| R900246858 4WREEM6E08-2X/G24K34/B6V |
| R901229220 4WREEM6E1-08-2X/G24K34/B6V |
| R900778354 4WREEM6E1-16-2X/G24K34/B6V |
| R901037662 4WREEM6E1-32-2X/G24K34/B6V |
| R900246618 4WREEM6E16-2X/G24K34/B6V |
| R901289420 4WREEM6E16J-2X/G24K34/B6V-970 |
| R901426156 4WREEM6E32-2X/G24K34/B6M |
| R900707192 4WREEM6E32-2X/G24K34/B6V |
| R987067798 4WREEM6E32J-2X/G24K34/B6V-687-SO280 |
| R901132922 4WREEM6W04-2X/G24K34/B6V |
Q: What is the key feature of the "D" spool in 4WMM10D3X/?
A: The letter "D" denotes the spool type, which defines the internal flow path pattern in the center (neutral) position. For the D-type spool, the typical configuration is P port connected to T (tank), while A and B ports are blocked. This provides a "Tandem Center" function, which unloads the pump (P→T) in neutral, reducing heat generation, while holding the actuator (A/B blocked) to prevent drift.
Q: What is the difference between 4WMM10D3X/ and 4WMM10D3X/F?
A: The standard 4WMM10D3X/ (without the /F suffix) is spring-centered. This means the lever must be held in the left or right position; when released, it automatically returns to the center (neutral) position. The /F variant includes a detent mechanism that locks the lever in the selected position.
Q: What is the maximum flow and pressure?
A: This NG10 size valve is rated for a maximum working pressure of 315 bar on P, A, B ports, but the return port (T) is limited to 160 bar. The recommended maximum flow is 120 L/min to avoid excessive pressure drops.
Q: How is this valve mounted?
A: It is a subplate-mounted valve. It requires a separate NG10 base plate (mounting interface per ISO 4401-05-04-0-05) that is screwed onto the manifold or tank. The valve then mounts onto this base plate.
Q: What are the critical installation warnings?
A:
Port T Pressure: The return port (T) has a significantly lower pressure rating (160 bar) than the P, A, B ports (315 bar). Ensure your system's backpressure does not exceed this limit, as high backpressure can damage the valve and cause leakage.
Cleanliness: The valve contains precision spools. Install it only in a clean environment and flush the system thoroughly before commissioning.
Q: How do I connect the ports?
A: The standard port configuration is:
P: Pressure In (from pump)
T: Tank Return
A, B: Work ports (to cylinder or motor)
Q: The lever is very hard to operate. What is wrong?
A: High operating force is usually due to:
High System Pressure: The spool is under pressure, creating a hydraulic lock. Operate the lever only when the system pressure is low or relieved.
Contamination: Dirt or varnish inside the valve can cause the spool to stick. Check the oil cleanliness (ISO 4406 Class 20/18/15 or cleaner is recommended).
Q: The cylinder drifts slowly when the valve is in the center position.
A: This is typically not a valve failure but a function of the D-type spool. The D-spool is designed to block A and B in the center, which should hold the actuator. If drift occurs, it is likely due to:
Actuator Leakage: Worn seals in the cylinder or motor itself.
Spool Wear: Contamination causing erosion of the spool edges, allowing internal leakage past the lands.
Q: There is external leakage from the shaft or mounting area.
A: This indicates worn shaft seals or a damaged O-ring between the valve and the subplate. The valve requires disassembly and resealing. Ensure the mounting bolts are torqued correctly to avoid warping the subplate.
Q: What type of oil and cleanliness are required?
A: Use ISO VG 32/46/68 mineral-based oils (HL, HLP). The oil cleanliness must be NAS Class 9 or cleaner (ISO 4406 18/16/13) for long service life. Contamination is the primary cause of spool sticking and wear.
Q: Can I repair this valve myself?
A: Limited repair is possible. Seal kits are available for replacing external O-rings and shaft seals. However, repairing or lapping the internal spool and body requires specialized equipment. For critical applications, replacing the valve is often more reliable than attempting a field repair.
Q: What is the expected service life?
A: Under correct conditions (clean oil, within pressure ratings), the mechanical life can be several million cycles. The primary failure modes are seal wear and spool sticking due to contamination.
Disclaimer: This data is based on standard Rexroth WMM series documentation. The exact center position flow pattern is defined by the "D" code, which should be verified with the supplier's datasheet. Always refer to the official technical data (RE 25706 or similar) for your specific application and safety guidelines.
Người liên hệ: Mr. liyun