Thông tin chi tiết sản phẩm:
|
| Đầu nối điện: | Đầu nối thiết bị 3 chân (2+PE) (K4) theo EN 175301-803 | Giao diện gắn kết: | ISO 4401-03-02-0-05 (tấm phụ NG6) |
|---|---|---|---|
| Vật liệu đóng dấu: | NBR (M) | Tối đa. Công suất dòng chảy: | 30 lít/phút |
| Phạm vi áp suất có thể điều chỉnh: | 0 – 210 bar (tỷ lệ điện) |
|
Parameter |
Specification |
|---|---|
|
Order Number |
R900928873 |
|
Model |
DRE6-1X/210MG24K4M |
|
Type |
Pilot-operated proportional pressure reducing valve (3-way spool type) |
|
Function |
Reduce inlet pressure (P) to a controlled secondary pressure (A) |
|
Nominal Size |
NG6 (CETOP 3, Size 6) |
|
Max. Operating Pressure |
Port P (Inlet): 315 bar |
|
Adjustable Pressure Range |
0 – 210 bar (electrically proportional) |
|
Max. Flow Capacity |
30 L/min |
|
Valve Design |
Pilot-operated spool valve, requires external amplifier |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
Requires external amplifier (e.g., VT-5000) for 0–10 V or 4–20 mA input |
|
Electrical Connector |
3-pin (2+PE) device connector (K4) per EN 175301-803 |
|
Mounting Interface |
ISO 4401-03-02-0-05 (NG6 subplate) |
|
Seal Material |
NBR (M) |
|
Suitable Media |
Mineral oils (HL, HLP), HVLP, HFC, HLPD, HVLPD |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
15 – 380 mm²/s (recommended 30–46 mm²/s) |
|
Ambient Temperature |
-20°C to +70°C |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Control Performance |
Hysteresis ≤ ±2.5 %, Linearity ±3.5 %, Repeat accuracy < ±2 % |
|
Weight |
Approx. 1.76 kg |
![]()
| R900967050 ZDRE6VP1-1X/100MG24K4M |
| R900958957 ZDRE6VP1-1X/100MG24K4V |
| R901252622 ZDRE6VP1-1X/100MG24N9K4M |
| R901252623 ZDRE6VP1-1X/100MG24N9K4V |
| R900915958 ZDRE6VP1-1X/100MG24NK4M |
| R900933523 ZDRE6VP1-1X/100MG24NK4V |
| R900536114 ZDRE6VP1-1X/100MG24NZ4M |
| R900537078 ZDRE6VP1-1X/100MG24Z4M |
| R900914590 ZDRE6VP1-1X/100MG24Z4V |
| R900966203 ZDRE6VP1-1X/210MG24K4M |
| R900719800 ZDRE6VP1-1X/210MG24K4V |
| R901252624 ZDRE6VP1-1X/210MG24N9K4M |
| R901252625 ZDRE6VP1-1X/210MG24N9K4V |
| R900915959 ZDRE6VP1-1X/210MG24NK4M |
| R900915960 ZDRE6VP1-1X/210MG24NK4V |
| R900536527 ZDRE6VP1-1X/210MG24NZ4M |
| R900551016 ZDRE6VP1-1X/210MG24NZ4V |
| R900569277 ZDRE6VP1-1X/210MG24Z4M |
| R900902595 ZDRE6VP1-1X/210MG24Z4V |
| R901442570 ZDRE6VP1-1X/315MG24N9K4M |
| R900617992 ZDRE6VP1-1X/50MG24K4M |
| R901106374 ZDRE6VP1-1X/50MG24K4V |
| R901252626 ZDRE6VP1-1X/50MG24N9K4M |
| R901252627 ZDRE6VP1-1X/50MG24N9K4V |
| R900915961 ZDRE6VP1-1X/50MG24NK4M |
| R900946738 ZDRE6VP1-1X/50MG24NK4V |
| R900550552 ZDRE6VP1-1X/50MG24NZ4M |
| R900901823 ZDRE6VP1-1X/50MG24Z4M |
| R900930942 ZDRE6VP2-1X/100MG24K4M |
| R900950897 ZDRE6VP2-1X/100MG24K4V |
| R901252628 ZDRE6VP2-1X/100MG24N9K4M |
| R901252629 ZDRE6VP2-1X/100MG24N9K4V |
| R900574926 ZDRE6VP2-1X/100MG24NK4M |
FAQ:
High Reduced Pressure Rating (210 bar)
The "210" denotes the maximum electrically adjustable reduced pressure at port A. The inlet at port P can be up to 315 bar, but the valve will regulate port A to a maximum of 210 bar. This is the high-pressure variant of the DRE6 series (compared to the 100 bar and 50 bar versions).
Requires External Amplifier
Unlike the DREE series with integrated electronics (OBE), the DRE6 series requires an external proportional amplifier (e.g., Rexroth VT-5000 series). The valve's coil is driven by the amplifier, which accepts the command signal (0–10 V or 4–20 mA). The "M" in the code indicates a standard proportional solenoid coil.
3-Way Function (P, A, T)
This valve has three working ports: P (inlet), A (reduced pressure outlet), and T (tank). It continuously compares the A-port pressure with the electrical setpoint. If A-port pressure is too high, it opens a path to T to bleed off excess pressure and maintain the set value.
Pilot-Operated Design
This is a pilot-operated valve, not a direct-operated poppet. It uses a small pilot flow (approx. 0.65 L/min) for control, which allows for higher main flow capacity (30 L/min) and faster response compared to direct-operated valves.
Critical Installation Notes
External Amplifier Needed: You must use an external amplifier card to drive the valve. The K4 connector on the valve only carries coil power from the amplifier.
Tank Line Backpressure: Port T must be connected directly to tank with minimal backpressure. High backpressure at T will be added to the A-port pressure, causing inaccurate regulation.
Pilot Flow: Ensure your system can supply the small pilot flow required for the valve's internal operation.