Product Details:
|
| Weight: | 1.4 – 2.3 Kg | Cleanliness Requirement: | ISO 4406 20/18/15 Or Better |
|---|---|---|---|
| Media Temperature: | -20°C To +80°C | Solenoid Current: | Approx. 1600 MA (at Max. Pressure) |
| Max. Operating Pressure: | Port P: 420 Bar |
|
Parameter |
Specification |
|---|---|
|
Order Number |
R901000846 |
|
Model |
DBET-6X/200G24K4V |
|
Type |
Direct-operated proportional pressure relief valve (seat type) |
|
Function |
2-port, normally closed (P → T) |
|
Nominal Size |
NG6 (Size 6) |
|
Max. Operating Pressure |
Port P: 420 bar |
|
Adjustable Pressure Range |
0 – 200 bar (electrically proportional) |
|
Rated Flow |
2 L/min (maximum controlled flow) |
|
Valve Design |
Direct-operated poppet (seat valve), without integrated electronics (OBE) |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
External amplifier required (e.g., ±10 V or 0–20 mA input to amplifier) |
|
Solenoid Current |
Approx. 1600 mA (at max. pressure) |
|
Electrical Connector |
3-pole plug socket (K4) per EN 175301-803 (2 poles + PE) |
|
Mounting Interface |
ISO 4401-03-02-0-05 (NG6 subplate) |
|
Seal Material |
FKM (Viton) (V) |
|
Suitable Media |
Mineral oils (HL, HLP), biodegradable oils (HETG, HEES), HFDU fluids |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
20 – 380 mm²/s (recommended 30–46 mm²/s) |
|
Ambient Temperature |
-20°C to +70°C |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Hysteresis |
< 4 % |
|
Step Response Time |
Approx. 80 ms (0% → 100% pressure) |
|
Weight |
Approx. 1.4 – 2.3 kg (depending on connector) |
![]()
| DBETBEX-1X/315G24K31F1M |
| DBETBEX-1X/315G24K31F1V |
| DBETBEX-1X/80G24K31A1M |
| DBETBEX-1X/80G24K31F1M |
| DBETBEX-1X/80G24K31F1V |
| DBE6X-1X/315G24-8NZ4M |
| DBET-6X/100G24-8K4V |
| DBET-6X/100G24K4M |
| DBET-6X/100G24K4V |
| DBET-6X/100YG24-8K4V |
| DBET-6X/100YG24-8K4V-7 |
| DBET-6X/100YG24K4M |
| DBET-6X/100YG24K4V |
| DBET-6X/200G24-8K4V |
| DBET-6X/200G24K4M |
| DBET-6X/200G24K4V |
| DBET-6X/200G24K4V=LB |
| DBET-6X/200YG24-8K4V |
| DBET-6X/200YG24-8K4V-7 |
| DBET-6X/200YG24K4M |
| DBET-6X/200YG24K4V |
| DBET-6X/250G24K4M |
| DBET-6X/250YG24K4M |
| DBET-6X/315G24-8K4M |
| DBET-6X/315G24-8K4V |
| DBET-6X/315G24K4M |
| DBET-6X/315G24K4V |
| DBET-6X/315G24K4V=DE |
| DBET-6X/315G24K4V=LB |
| DBET-6X/315YG24-8K4M |
| DBET-6X/315YG24-8K4V |
| DBET-6X/315YG24-8K4V-7 |
| DBET-6X/315YG24K4M |
| DBET-6X/315YG24K4V |
| DBET-6X/350G24K4VRD29162 |
| DBET-6X/350G24-8K4M |
| DBET-6X/350G24-8K4V |
| DBET-6X/350G24K4M |
| DBET-6X/350G24K4V |
| DBET-6X/350YG24-8K4M |
| DBET-6X/350YG24-8K4V |
| DBET-6X/350YG24-8K4V-7 |
| DBET-6X/350YG24K4M |
| DBET-6X/350YG24K4V |
| DBET-6X/420G24-8K4V |
| DBET-6X/420G24K4V |
| DBET-6X/420YG24K4V |
FAQ:
Direct-Operated Seat Design (DBET)
This valve uses a poppet and seat mechanism directly actuated by a proportional solenoid. It provides excellent sealing (zero leakage at closed center) and fast response but has a very low flow capacity (only 2 L/min). It is designed for pressure control, not for high-flow bypass.
External Electronics Required (/K4)
The suffix /K4 indicates a 3-pole plug socket for connection to an external control amplifier (e.g., Rexroth VT-5000 series). The valve itself has no on-board electronics (OBE), so you must provide an external amplifier that delivers the controlled current to the solenoid.
Pressure Setting (200)
The "200" denotes the maximum adjustable pressure rating of 200 bar. The valve can be set proportionally from a minimum pressure (typically a few bar at 0 V/mA) up to 200 bar at maximum command signal.
Seal Material (V)
The /V suffix specifies FKM (Viton) seals, which are suitable for a wide range of hydraulic fluids, including standard mineral oils and many fire-resistant fluids (HFDU). This offers better chemical resistance than standard NBR seals.
Critical Installation Notes
External Amplifier: You must use a compatible proportional amplifier. The control signal (e.g., ±10 V) is input to the amplifier, which then drives the solenoid coil.
Flow Limitation: This valve is not a main system relief valve for high flows. It is typically used as a pilot valve for larger cartridge valves or for precise pressure control in small circuits. Exceeding the 2 L/min flow rating will cause excessive pressure override.
Return Line Pressure: Port T (return) must be connected directly to tank with minimal backpressure. High backpressure will directly reduce the effective setting pressure (P_set = P_solenoid - P_T).
Contact Person: Mr. liyun
Tel: +8615280488899