Product Details:
|
| Mounting: | According To ISO 4401-05 (CETOP 5) | Weight (approx.): | ~3.0 Kg (with Coil) |
|---|---|---|---|
| Recommended Viscosity Range: | 10 To 400 Mm²/s | Model: | 4WE 10 G5X/HG24N9K4/M |
| Connection Size (P/A/B/T): | G 1/4" | ||
| Highlight: | Rexroth 4WE10 directional solenoid valve,Rexroth hydraulic solenoid valve with warranty,4WE10G5X HG24N9K4 directional control valve |
||
|
Parameter |
Value / Description |
|---|---|
|
Valve Type |
Solenoid-operated directional control valve |
|
Model |
4WE 10 G5X/HG24N9K4/M |
|
Design |
Wet-pin solenoid; Subplate mounting |
|
Connection Size (P/A/B/T) |
G 1/4" |
|
Nominal Size |
10 mm |
|
Maximum Operating Pressure |
315 bar |
|
Maximum Flow Rate |
60 l/min |
|
Number of Positions/Ways |
4-way, 3-position |
|
Spool Type (G5X) |
Pressure port P blocked, work port A connected to pressure P, work port B connected to tank T in center position ("A pressure, B tank center" or "Mid-position supply to A") |
|
Control Method |
Single solenoid, with spring return to center |
|
Solenoid Specification (HG24N9K4) |
24V DC; with manual override; plug connector (DIN 43650 Form A) |
|
Operating Voltage |
24V DC |
|
Power Consumption |
Typically ~22W (Confirm with official datasheet) |
|
Protection Class (Coil) |
IP65 standard |
|
Duty Cycle |
100% |
|
Mounting |
According to ISO 4401-05 (CETOP 5) |
|
Weight (approx.) |
~3.0 kg (with coil) |
|
Housing Material |
Aluminum alloy |
|
Sealing Material |
Nitrile rubber (NBR) standard; FKM optional |
|
Fluid Temperature Range |
-20 °C to +80 °C (with NBR seals) |
|
Recommended Viscosity Range |
10 to 400 mm²/s |
|
Fluid Compatibility |
Mineral oils (HL, HLP per ISO 6743-4) |
|
Filtration Requirement |
Cleanliness class 20/18/15 per ISO 4406 (recommended) |
![]()
| 4WE10A33/CG24N9K4 |
| 4WE10A33/CW230N9K4 |
| 4WE10C33/CG24N9K4 |
| 4WE10C33/CW230N9K4 |
| 4WE10D33/CG24N9K4 |
| 4WE10D33/CW230N9K4 |
| 4WE10B33/CG24N9K4 |
| 4WE10B33/CW230N9K4 |
| 4WE10Y33/CG24N9K4 |
| 4WE10Y33/CW230N9K4 |
| 4WE10E33/CG24N9K4 |
| 4WE10E33/CW230N9K4 |
| 4WE10F33/CG24N9K4 |
| 4WE10F33/CW230N9K4 |
| 4WE10G33/CG24N9K4 |
| 4WE10G33/CW230N9K4 |
| 4WE10H33/CG24N9K4 |
| 4WE10H33/CW230N9K4 |
| 4WE10J33/CG24N9K4 |
| 4WE10J33/CW230N9K4 |
| 4WE10M33/CG24N9K4 |
| 4WE10M33/CW230N9K4 |
| 4WE10Q33/CG24N9K4 |
| 4WE10Q33/CW230N9K4 |
| 4WE10R33/CG24N9K4 |
| 4WE10R33/CW230N9K4 |
| 4WE10T33/CG24N9K4 |
| 4WE10T33/CW230N9K4 |
| 4WE10U33/CG24N9K4 |
| 4WE10U33/CW230N9K4 |
| 4WE10V33/CG24N9K4 |
| 4WE10V33/CW230N9K4 |
| 4WE10W33/CG24N9K4 |
| 4WE10W33/CW230N9K4 |
| 0811404613 4WRPEH6C4B40L-2X/G24K0/A1M |
| 0811404801 4WRPEH10C3B100L-2X/G24K0/A1M |
| 0811404680 4WRLE10Q3-85M-3X/G24ETK0/A1M |
| 0811404342 4WRLE16Q3-200M-3X/G24K0/A1M |
| R901131953 4WRLE25Q3-370M-3X/G24K0/A1M |
| 0811404438 4WRLE27Q4-430M-3X/G24K0/A1M |
| 0811404430 4WRLE25V370M-3X/G24K0/A1M |
| 0811402071 DBETBEX-1X/180G24K31A1M |
| 0811402003 DBETBX-1X/180G24-37Z4M |
| 0811403001 4WRP10EA63S-1X/G24Z4/M |
| 0811402036 DBETX-1X/50G24-8NZ4M |
| 0811402019 DBETX-1X/250G24-8NZ4M |
| 0811402016 DBETX-1X/315G24-8NZ4M |
| 0811402017 DBETX-1X/180G24-8NZ4M |
| 0811402055 DRE6X-1X/175MG24-8NZ4M |
| R900907114 4WREE6E32-2X/G24K31/A1V |
| R900911004 4WREE6W32-2X/G24K31/A1V |
| R900927230 4WREE10E75-2X/G24K31/A1V |
| R900927233 4WREE10W75-2X/G24K31/A1V |
| R902436353 A10VSO100 DRS/32R-VPB12N00 |
| R900955887 3DREP6C-2X/25EG24N9K4/M |
| R900954427 3DREPE6C-21/25EG24K31/A1M |
| R900958848 3DREPE6C-21/25EG24N9K31/F1M |
| R900561180 3WE 6 A6X/EG24N9K4 |
| R900592014 3WE10 A5X/EG24N9K4/M |
| R901391203 4WE 10 C5X/HG24N9K4/M |
Q1: What is the unique function of the "G5X" spool?
A: The "G5X" spool has a specialized center position. In neutral, it blocks the main pressure port (P), connects work port A to the pressure line, and connects work port B to the tank (T). This applies pressure to one side of an actuator and drains the other side simultaneously while the valve is centered.
Q2: What is this center position configuration typically used for?
A: This is a differential or "mid-position" function. It is typically used to pre-position or hold a hydraulic cylinder in a specific intermediate state when the valve is not actively being shifted. Common applications include holding a clamping cylinder partially extended or maintaining a specific position in a multi-stage system.
Q3: How is the valve operated?
A: It is controlled by a single 24V DC solenoid ("HG24N9K4" coil). Energizing the solenoid shifts the spool to a full working position. De-energizing it allows internal springs to return the spool to the specialized differential center position described above. A manual override is provided for testing.
Q4: What are the pressure and flow ratings?
A: Maximum operating pressure: 315 bar. Maximum recommended flow rate: 60 liters per minute.
Q5: What are the electrical specifications?
A: The solenoid operates on 24V DC, with a protection class of IP65. Please refer to the official data sheet for exact power consumption and current ratings.
Q6: How is the valve installed?
A: It mounts on a standard ISO 4401-05 (CETOP 5) subplate. The hydraulic ports are G 1/4". Electrical connection is via a plug connector.
Q7: What are the fluid requirements?
A: Use standard mineral-based hydraulic oils (HL, HLP). Maintaining high fluid cleanliness (ISO 4406 20/18/15 recommended) with proper filtration is essential for reliable operation.
Q8: Where can I find the complete technical data?
A: For the complete datasheet, performance curves, and the exact hydraulic symbol for this specific spool type, please consult the official technical documentation for order code R901427832.
Contact Person: Mr. liyun
Tel: +8615280488899