logo
Home ProductsRexroth Hydraulic Pump

PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock

I'm Online Chat Now

PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock

PV7-1X/16-20RE01MN0-16	
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock
PV7-1X/16-20RE01MN0-16	
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock PV7-1X/16-20RE01MN0-16	
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock

Large Image :  PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock

Product Details:
Place of Origin: Germany
Brand Name: Rexroth
Certification: ISO
Model Number: PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,Western Union,T/T,D/A,D/P,L/C
Supply Ability: 100

PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock

Description
Operation Protection: Noise Level Abnormality Threshold Control Signal: PWM Signal Duty Cycle Operating Range*
Highlight:

Rexroth hydraulic vane pump

,

German imported oil pump

,

PV7 blade vane pump

Rexroth PV7 Series Hydraulic Vane Pumps
Available Models
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16

German-engineered hydraulic vane pumps with pressure compensation control, available from stock.

Technical Specifications
Parameter Specification
Suction Pressure Range -0.8 to +1 bar (absolute pressure: 0.2-1.1 bar)
Compatible Hydraulic Fluids Mineral oil (HLP) and synthetic oil (HETG/HEES); use FKM seals for synthetic fluids
Fluid Viscosity Range 10-1000 mm²/s (operation); 2-1500 mm²/s (start-up); optimal range is 16-160 mm²/s
Fluid Temperature Range -20 to +80 °C (operation); -40 to +90 °C (storage)
Noise Level (Direct-Acting) ≤63 dB(A) at 1 m distance under rated operation
Noise Level (Pilot-Operated) ≤65 dB(A) at 1 m distance under rated operation
Mounting Standard ISO 3019-2 flange; optional foot mounting for some models
Shaft Connection ISO 4162 splined shaft; keyed shaft available on request
Seal Materials NBR (standard, for mineral oil) and FKM (optional, for synthetic oil)
Weight Range (Direct-Acting) 8-12 kg (depends on displacement)
Weight Range (Pilot-Operated) 10-35 kg (depends on displacement and control type)
Control Type (PV7-A Series) Direct-acting pressure compensation
Control Type (PV7-C/D/N/W Series) Pilot-operated pressure/flow control
Pressure Rise Response Time 40-60 ms (both direct-acting and pilot-operated)
Housing Material GG25 cast iron (high strength and vibration resistance)
Rotor and Stator Material 42CrMo4 alloy steel (quenched & tempered for high hardness and wear resistance)
Vane Material Wear-resistant powder metallurgy alloy (self-lubricating and anti-seizure)
Service Life 8000-10000 operating hours (depends on oil cleanliness and maintenance)
Case Drain Flow Range (Direct-Acting) 1.5-2.5 l/min at rated pressure (varies with displacement and pressure)
PV7-1X/16
<div class=Additional Model Variants
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
PV7-1X/10-14RE01MC0-16-P45
PV7-1X/25-45RE01MN0-08
PV7-1X/25-30RE01MC0-16
PV7-1X/63-94RE07MC0-08-P75
PV7-1X/63-71RE07MW5-16WH
PV7-1X/25-30RE01MC5-16
PV7-1X/40-71RE37MD0-08
PV7-1X/100-150RE07MD0-08
PV7-1X/10-20RE01MC7-10
PV7-1X/10-14RE01MD3-16
PV7-1X/100-118RE07MW0-16WH
PV7-1X/100-118RE07KD0-16
PV7-1X/10-14RE01MC5-16
PV7-1X/63-94RE07MN0-08
PV7-1X/10-14RE01KC0-16
PV7-1X/40-45RE37MC3-16
PV7-1X/40-45RE37MC7-16
PV7-1X/16-20RE01MC0-16-C3.1
PV7-1X/40-45RE37MC0-16-A446
PV7-1X/100-118RE07MW0-16WG
PV7-1X/100-150RE07MC0-08
PV7-1X/63-94RE07MC5-08WG
PV7-1X/16-20RE01KC0-16
PV7-1X/40-55RE37MC0-08-A449
PV7-1X/63-94RE07MD0-08
PV7-1X/16-20RE01MD0-16-Q25
PV7-1X/40-45RE37MD0-16-P50Q39
PV7-1X/63-71RE07MD0-16-Q65
PV7-1X/16-30RE01MC0-08
PV7-1X/40-45RE37MW0-16
PV7-1X/40-71RE37MC0-08
PV7-1X/100-118RE07MW6-16WH
PV7-1X/16-30RE01MC5-08WG
PV7-1X/10-20RE01MC0-10
PV7-1X/63-71RE07MW0-16
PV7-1X/63-94RE07KC0-08
PV7-1X/40-45RE37MC7-16WH
PV7-1X/10-14RE01MC0-16-P60Q15
PV7-1X/63-71RE07KW0-16WG
PV7-1X/100-118RE07KC5-16
PV7-1X/25-30RE01MC7-16
PV7-1X/63-71RE07MC5-16
PV7-1X/25-30RE01KD0-16
PV7-1X/10-14RE01MC5-16WH
PV7-1X/10-20RE01MC0-10-P45
PV7-1X/16-20RE01MW0-16
PV7-1X/16-30RE01MD0-08
PV7-1X/25-45RE01MD0-08
PV7-1X/100-118RE07MC7-16
PV7-1X/10-14RE01MC0-16-P90
PV7-1X/16-20RE01MC7-16WH
PV7-1X/40-45RE37MD0-16-C3.1
PV7-1X/40-45RE37MW0-16WG
PV7-1X/40-45RE37KD0-16
PV7-1X/40-45RE37MC0-16-P80
PV7-1X/16-30RE01MC5-08
PV7-1X/100-150RE07KD0-08
PV7-1X/40-45RE37MW0-16WH
PV7-1X/10-14RE01MD0-16
PV7-1X/100-150RE07MC5-08WG
PV7-1X/16-30RE01MC7-08
PV7-1X/63-71RE07MC0-06-A460
PV7-1X/10-14RE01MC0-16
PV7-1X/16-30RE01MN0-08
PV7-1X/25-45RE01KC0-08
Maintenance & Monitoring Guidelines
Optimal Fluid Viscosity Operating Range
Set to 10-40 mm²/s, matching the viscosity specifications of your hydraulic fluid.
Fluid Contamination Particle Count Threshold
Should be set to meet ISO cleanliness standards (≤ ISO 18/15/12) to trigger filter replacement alerts.
Maximum Allowable Fluid Moisture Content Alarm Threshold
Set to ≤0.1% to detect fluid degradation caused by water contamination early.
Fluid Replacement Maintenance Reminder Interval
Set to 100-5000 hours based on your system's operating conditions and fluid maintenance guidelines.
Filter Pressure Drop Clogging Alarm Threshold
Triggers an alert when pressure drop exceeds 2 bar, indicating the hydraulic filter is clogged and needs replacement.
Electrical Configuration

Contact technical support for specific electrical configuration requirements based on your application.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)