German Rexroth Pilot PV7 Vane Oil Pump Original Imported Hydraulic Pump
Product Models
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
Compatible Pump Specifications
| Pump Type |
OEM Part Number |
Applicable Equipment Model |
Displacement (cc/r) |
Rated Pressure (MPa) |
| Axial Piston Pump |
487-6207 |
301.5/301.6/301.7CR |
12.5 |
28 |
| Axial Piston Pump |
423-0097 |
305.5E/306E/307E |
65 |
32 |
| Axial Piston Pump |
272-6959 |
325D/329D/DL |
145 |
35 |
| Axial Piston Pump |
369-9655 |
374F/390F |
280 |
38 |
| Axial Piston Pump |
307-3063 |
415F/416F/422F |
112 |
31 |
| Gear Pump (Pilot) |
560-0886 |
Full Range Excavators |
8.2 |
21 |
| Axial Piston Pump |
295-9426 |
349 Series |
160 |
36 |
| Gear Pump (Auxiliary) |
175-6253 |
Loaders/Backhoes |
10.5 |
24 |
![PV7-1X/25-
<div class=]()
Additional Model Variants
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
PV7-1X/10-14RE01MC0-16-P45
PV7-1X/25-45RE01MN0-08
PV7-1X/25-30RE01MC0-16
PV7-1X/63-94RE07MC0-08-P75
PV7-1X/63-71RE07MW5-16WH
PV7-1X/25-30RE01MC5-16
PV7-1X/40-71RE37MD0-08
PV7-1X/100-150RE07MD0-08
PV7-1X/10-20RE01MC7-10
PV7-1X/10-14RE01MD3-16
PV7-1X/100-118RE07MW0-16WH
PV7-1X/100-118RE07KD0-16
PV7-1X/10-14RE01MC5-16
PV7-1X/63-94RE07MN0-08
PV7-1X/10-14RE01KC0-16
PV7-1X/40-45RE37MC3-16
PV7-1X/40-45RE37MC7-16
PV7-1X/16-20RE01MC0-16-C3.1
PV7-1X/40-45RE37MC0-16-A446
PV7-1X/100-118RE07MW0-16WG
PV7-1X/100-150RE07MC0-08
PV7-1X/63-94RE07MC5-08WG
PV7-1X/16-20RE01KC0-16
PV7-1X/40-55RE37MC0-08-A449
PV7-1X/63-94RE07MD0-08
PV7-1X/16-20RE01MD0-16-Q25
PV7-1X/40-45RE37MD0-16-P50Q39
PV7-1X/63-71RE07MD0-16-Q65
PV7-1X/16-30RE01MC0-08
PV7-1X/40-45RE37MW0-16
PV7-1X/40-71RE37MC0-08
PV7-1X/100-118RE07MW6-16WH
PV7-1X/16-30RE01MC5-08WG
PV7-1X/10-20RE01MC0-10
PV7-1X/63-71RE07MW0-16
PV7-1X/63-94RE07KC0-08
PV7-1X/40-45RE37MC7-16WH
PV7-1X/10-14RE01MC0-16-P60Q15
PV7-1X/63-71RE07KW0-16WG
PV7-1X/100-118RE07KC5-16
PV7-1X/25-30RE01MC7-16
PV7-1X/63-71RE07MC5-16
PV7-1X/25-30RE01KD0-16
PV7-1X/10-14RE01MC5-16WH
PV7-1X/10-20RE01MC0-10-P45
PV7-1X/16-20RE01MW0-16
PV7-1X/16-30RE01MD0-08
PV7-1X/25-45RE01MD0-08
PV7-1X/100-118RE07MC7-16
PV7-1X/10-14RE01MC0-16-P90
PV7-1X/16-20RE01MC7-16WH
PV7-1X/40-45RE37MD0-16-C3.1
PV7-1X/40-45RE37MW0-16WG
PV7-1X/40-45RE37KD0-16
PV7-1X/40-45RE37MC0-16-P80
PV7-1X/16-30RE01MC5-08
PV7-1X/100-150RE07KD0-08
PV7-1X/40-45RE37MW0-16WH
PV7-1X/10-14RE01MD0-16
PV7-1X/100-150RE07MC5-08WG
PV7-1X/16-30RE01MC7-08
Technical Specifications & Safety Information
Q: What is the maximum safe value for the High-Temperature Warning Threshold?
A: Do not set it above 80°C to avoid triggering unnecessary alerts while still monitoring fluid temperature effectively.
Q: Can the High-Temperature Shutdown Safety Limit be modified?
A: This is a non-adjustable safety limit (typically ≤90°C) designed to prevent pump overheating damage.
Q: How long should the Low-Temperature Cold-Start Delay be set for?
A: Set it to 10-120 seconds to allow the hydraulic fluid to preheat and ensure proper lubrication during cold starts.
Q: What does the Vibration Abnormality Alarm Threshold detect?
A: It monitors pump housing vibration (≤5 m/s²) and triggers an alert if vibration levels indicate mechanical faults.
Q: When will the Noise Level Abnormality Threshold alert the user?
A: It triggers an alert when noise levels exceed 85 dB, which may indicate fluid cavitation or component wear.
Control Signal