logo
Home ProductsRexroth Hydraulic Pump

PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump

I'm Online Chat Now

PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump

PV7-1X/06-10RE01MA0-10
PV7-2X/20-25RE01MA0-05	
PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump
PV7-1X/06-10RE01MA0-10
PV7-2X/20-25RE01MA0-05	
PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump PV7-1X/06-10RE01MA0-10
PV7-2X/20-25RE01MA0-05	
PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump

Large Image :  PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,T/T,Western Union,D/A,L/C,D/P
Supply Ability: 100

PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10 Hydraulic oil pump, German Rexroth original blade pump, spot imported hydraulic pump

Description
What Is The Model Range Of The Direct-acting PV7 Series?: PV7-1X/06-10RE01MA0-10 PV7-2X/20-25RE01MA0-05 PV7-1X/06-10RE01MA3-10 What Is The Model Range Of The Pilot-operated PV7 Series?: PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16
What Does "1X/2X" Represent In The PV7 Model Code?: It Indicates The Component Series Of The Pump What Is The Displacement Per Revolution Range Of The Direct-acting PV7 Series?: 10–25 Cm³/rev
What Is The Displacement Per Revolution Range Of The Pilot-operated PV7 Series?: 14–150 Cm³/rev
Highlight:

Rexroth original hydraulic vane pump

,

German imported hydraulic oil pump

,

spot imported Rexroth blade pump

Product Information
PV7 Series Hydraulic Vane Pumps
PV7-1X/06-10RE01MA0-10
PV7-2X/20-25RE01MA0-05
PV7-1X/06-10RE01MA3-10

German Rexroth original hydraulic vane pumps, spot imported hydraulic pumps designed for industrial applications requiring reliable fluid power transmission.

Technical Specifications
Parameter Specification
Model Series PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typical models)
Displacement per Revolution 10-25 cm³/rev (varies by specific model)
Maximum Operating Pressure 210 bar (continuous), 250 bar (peak)
Maximum Speed 1800-3600 rpm (depends on displacement and fluid viscosity)
Minimum Speed 600 rpm (ensures stable operation)
Fluid Medium Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended)
Fluid Temperature Range -20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range 10-1000 mm²/s (operation); 2-1500 mm²/s (start-up)
Volumetric Efficiency ≥90% (at rated pressure and speed)
Total Efficiency ≥80% (at rated working condition)
Noise Level ≤65 dB(A) (at 1 m distance under rated operation)
Suction Pressure -0.8 bar to +1 bar (absolute pressure: 0.2-1.1 bar)
Mounting Type Flange mounting (ISO 3019-2 standard), foot mounting (optional)
Shaft Connection Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Seal Type Viton® or NBR shaft seals (resistant to high temperature and oil)
Inlet/Outlet Port BSPP, BSPT or SAE thread (port size matches displacement)
Weight 8-15 kg (varies by model and configuration)
PV7-1X/0
<div class=Available Model Variants
PV7-2X/20-20RA01MA0-05-P50
PV7-1X/06-14RA01MA0-10-A473
PV7-1X/06-10RA01MA0-10-P100
PV7-1X/06-14RA01MA0-10-A492
PV7-2X/20-20RA01MA0-10-C3.1
PV7-2X/20-20RA01MA0-05-A480
PV7-2X/20-20RA01MA0-10-A480
PV7-1X/06-10RA01MA0-10-C3.1
PV7-2X/20-20RA01MA0-10-P100
PV7-2X/20-25RA01MA0-05-P24Q30
PV7-1X/06-10RA01MA0-05-P35Q11
PV7-2X/20-25RA01MA0-05-P30Q25
PV7-1X/06-10RA01MA0-05-P40Q11
PV7-2X/20-25RA01MA0-05-P30Q36
PV7-1X/06-10RA01MA0-05-P50Q15
PV7-2X/20-25RA01MA0-05-P45Q35
PV7-1X/06-10RA01MA0-10-P55Q12
PV7-2X/20-25RA01MA0-05-P45Q36
PV7-1X/06-10RA01MA0-10-P65Q12
PV7-2X/20-25RA01MA0-10-P63Q35
PV7-1X/06-10RA01MA0-10-P70Q12
PV7-1X/06-10RA01MA0-05-P15Q08
PV7-1X/06-14RA01MA0-07-P70Q18
PV7-1X/06-10RA01MA0-05-P25Q09
PV7-1X/06-14RA01MA0-04-P30Q19
PV7-1X/06-10RA01MA0-05-P25Q11
PV7-1X/06-10RA01MA0-10-P100Q10
PV7-1X/06-10RA01MA0-05-P35Q09
PV7-1X/63-71RE07MC3-16
PV7-1X/100-118RE07MD3-16
PV7-1X/63-71RE07MW0-16WG
PV7-1X/10-20RE01MD5-10
PV7-1X/25-30RE01MW0-16WG
PV7-1X/40-45RE37MW5-16WG
PV7-1X/100-118RE07MC5-16WG
PV7-1X/63-94RE07MC7-08WG
PV7-1X/40-45RE37MW6-16WH
PV7-1X/100-118RE07MD6-16
PV7-1X/40-45RE37MC5-16WG
PV7-1X/100-118RE07MC0-16
PV7-1X/63-71RE07MD0-16
PV7-1X/40-45RE37MC0-16-P90
PV7-1X/25-30RE01MC0-16-P100Q38
PV7-1X/100-150RE07MC0-08-A464
PV7-1X/100-118RE07MD0-16
PV7-1X/10-14RE01MN0-16
PV7-1X/40-45RE37MC5-16
PV7-1X/100-118RE07MC5-16
PV7-1X/25-30RE01KC3-16
PV7-1X/10-20RE01MC5-10WG
PV7-1X/25-30RE01MW0-16
PV7-1X/16-20RE01MD3-16
PV7-1X/16-20RE01MC0-16-P110
PV7-1X/40-45RE37KD0-16-C3.1
PV7-1X/63-71RE07MC5-16WH
PV7-1X/16-30RE01KC0-08
PV7-1X/10-14RE01MD5-16
PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16
PV7-1X/10-14RE01MW0-16
PV7-1X/63-71RE07MC0-16-C3.1
PV7-1X/16-30RE01MW0-08WH
PV7-1X/100-150RE07MC0-08-A446
PV7-1X/25-30RE01MC5-16WG
PV7-1X/10-20RE01MC0-10-A497
PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
Frequently Asked Questions
What is the minimum tank liquid level requirement for PV7 pump operation?
Maintain 1/2-2/3 of the tank volume to avoid insufficient suction.
What filter precision is required for the PV7 pump's suction line?
≤25μm coarse filter; submerge the filter ≥5cm below the liquid level to prevent air inhalation.
Is a pressure filter required for the PV7 pump system?
Recommended: ≤10μm pressure filter to protect the pump and control components.
How often should hydraulic oil be changed for PV7 pumps?
  • 500 hours (break-in period): First oil change
  • 2000 hours (normal operation): Regular oil change; adjust based on working conditions
What happens if the hydraulic oil viscosity is too high for the PV7 pump?
Increased suction resistance, poor blade movement, reduced flow rate, and increased energy consumption.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)