logo
Casa ProdutosBomba hidráulica Rexroth

R902473184 AA10VSO71DFR1/31R-VPA42N00 Bomba de pistão Rexroth Bomba hidráulica alemã

Estou Chat Online Agora

R902473184 AA10VSO71DFR1/31R-VPA42N00 Bomba de pistão Rexroth Bomba hidráulica alemã

R902473184 AA10VSO71DFR1/31R-VPA42N00 Piston pump Rexroth German hydraulic pump
R902473184 AA10VSO71DFR1/31R-VPA42N00 Piston pump Rexroth German hydraulic pump

Imagem Grande :  R902473184 AA10VSO71DFR1/31R-VPA42N00 Bomba de pistão Rexroth Bomba hidráulica alemã

Detalhes do produto:
Lugar de origem: alemão
Marca: Rexroth
Certificação: ISO
Número do modelo: R902473184 AA10VSO71DFR1/31R-VPA42N00
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 1
Detalhes da embalagem: caixa de madeira
Tempo de entrega: 2 semanas
Termos de pagamento: Western Union,T/T,D/P,D/A,L/C
Habilidade da fonte: 100

R902473184 AA10VSO71DFR1/31R-VPA42N00 Bomba de pistão Rexroth Bomba hidráulica alemã

descrição
Flange de montagem: ISO 3019-2 / SAE 2 parafusos Pressão de pico: 350 bar (intermitente)
Tamanho nominal: NG 71 Direção de rotação: Lado direito (R, sentido horário, visto da extremidade do eixo)
Tipo de eixo: Eixo com chave paralela (DIN 6885)
Destacar:

Rexroth bomba de pistão hidráulica alemã

,

bomba de pistão AA10VSO71DFR1

,

bomba de pistão hidráulica com garantia

Parâmetro

Especificação

Fabricante / Série​

Rexroth A10VSO Série 31

Código do pedido​

R902473184

Modelo Completo​

AA10VSO71DFR1/31R-VPA42N00

Tipo de bomba​

Bomba Variável de Pistão Axial (Design Swashplate, Circuito Aberto)

Tipo de controle​

DFR1​ (Controle de Pressão e Fluxo/Detecção de Carga)

Máx. Deslocamento​

71 cm³/rotação

Pressão Nominal​

280 bar (contínuo)

Pressão de Pico​

350 bar (intermitente)

Tamanho nominal​

NG 71

Direção de rotação​

Lado direito (R, sentido horário, visto da extremidade do eixo)

Tipo de eixo​

Eixo com chave paralela (DIN 6885)

Portas​

S (Sucção), B (Pressão), L (Dreno da Caixa), X (Controle LS)

Tamanho da porta​

Código 42 (Flange SAE, Roscas Métricas)

Flange de montagem​

ISO 3019-2 / SAE 2 parafusos

Máx. Velocidade​

2.200 rpm (em Vg máx), 2.600 rpm (com deslocamento reduzido)

Máx. Fluxo​

~156 L/min (a 2.200 rpm)

Material de vedação​

FKM (Viton)

Fluido Hidráulico​

Óleos minerais (HL, HLP), HETG, HEES, HFDU

Temperatura operacional​

-20°C a +80°C

Peso​

Aprox. 35,2kg

País de origem​

Alemanha

R902473184 AA10VSO71DFR1/31R-VPA42N00 Bomba de pistão Rexroth Bomba hidráulica alemã 0

R910944067  UM A10VSO 71 DFLR/31R-PPA12N00
R910946787  UM A10VSO 71 DFR/31L-PPA12N00
R910960472  UM A10VSO 71 DFR/31R-PPA12K01
R910963914  UM A10VSO 71 DFR/31R-PPA12K02
R902416246  UM A10VSO 71 DFR/31R-PPA12K07
R902428830  UM A10VSO 71 DFR/31R-PPA12K52
R910942635  UM A10VSO 71 DFR/31R-PPA12N00
R902439238  UM A10VSO 71 DFR/31R-PSA12K07   -S1627
R910960746  UM A10VSO 71 DFR1/31L-PPA12N00
R910947985  UM A10VSO 71 DFR1/31R-PPA12K01
R910947872  UM A10VSO 71 DFR1/31R-PPA12K02
R910966909  UM A10VSO 71 DFR1/31R-PPA12K04
R910963378  UM A10VSO 71 DFR1/31R-PPA12K07
R910991723  UM A10VSO 71 DFR1/31R-PPA12KB3
R910978724  UM A10VSO 71 DFR1/31R-PPA12KB4
R910968700  UM A10VSO 71 DFR1/31R-PPA12KB5
R910944440  UM A10VSO 71 DFR1/31R-PPA12N00
R910947992  UM A10VSO 71 DFR1/31R-PPA12N00   -SO 20
R910968701  UM A10VSO 71 DFR1/31R-PSA12N00
R910986932  UM A10VSO 71 DFR1/31R-VPA12K01
R910992519  UM A10VSO 71 DFR1/31R-VPA12N00
R902473183  UM A10VSO 71 DFR1/31R-VPA42K27
R902488176  UM A10VSO 71 DFR1/31R-VPA42KB5   -SO 52
R902501568  UM A10VSO 71 DFR1/31R-VSA12N00
R910960333  UM A10VSO 71 DR /31L-VPA12N00
R910998793  UM A10VSO 71 DR /31R-PPA12N00   -SO108
R910947219  UM A10VSO 71 DR /31R-VPA12N00
R902473969  UM A10VSO 71 DR /31R-VPA42KB5
R902482660  UM A10VSO 71 DR /31R-VPA42N00
R910947898  UM A10VSO 71 DRG/31R-PPA12N00
R910992951  UM A10VSO 71 DRG/31R-PSA12N00
R902411494  UM A10VSO 71 DRG/31R-VPA12K02
R910947258  UM A10VSO 71 DRG/31R-VPA12N00
R902452789  UM A10VSO 71 DRS/32R-VPB22U99
R902486410  UM A10VSO 71 DRS/32R-VRB32U01   -SO 52
R902486409  UM A10VSO 71 DRS/32R-VRB32U68   -SO 52
R910961157  UM A10VSO 71 FHD/31R-PPA12N00
R902460926  UM A10VSO100 DFLR/31R-VPA12N00
R910907813  UM A10VSO100 DFR/31L-PPA12N00
R910917313  UM A10VSO100 DFR/31R-PPA12K01
R910998331  UM A10VSO100 DFR/31R-PPA12K07
R910942637  UM A10VSO100 DFR/31R-PPA12K27
R902417327  UM A10VSO100 DFR/31R-PPA12KB4
R902416469  UM A10VSO100 DFR/31R-PPA12KB5
R910939643  UM A10VSO100 DFR/31R-PPA12N00
R910991002  UM A10VSO100 DFR/31R-PSA12N00
R910920969  UM A10VSO100 DFR/31R-VPA12N00
R910986270  UM A10VSO100 DFR1/31L-PPA12KB4   -SO 32
R910911394  UM A10VSO100 DFR1/31R-PPA12K01
R910927083  UM A10VSO100 DFR1/31R-PPA12K02
R910983124  UM A10VSO100 DFR1/31R-PPA12KB3
R910984741  UM A10VSO100 DFR1/31R-PPA12KB4
R910985609  UM A10VSO100 DFR1/31R-PPA12KB5
R902403231  UM A10VSO100 DFR1/31R-PPA12KB6
R910922744  UM A10VSO100 DFR1/31R-PPA12N00
R902418759  UM A10VSO100 DFR1/31R-PSA12KB4
R910971805  UM A10VSO100 DFR1/31R-PSA12KB6
R910949826  UM A10VSO100 DFR1/31R-PSA12N00
R910922681  UM A10VSO100DR /31L-VPA12N00
R910968839  UM A10VSO100DR /31R-PPA12K04
R910916809  UM A10VSO100DR /31R-VPA12N00

Perguntas frequentes (FAQ)

Q1: Qual é a função do controle "DFR1"?

UM:​ ODFR1é um combinadoControlador de Pressão e Fluxo. Ele fornece duas funções principais:

  1. Limitação de pressão: Atua como compensador de pressão, destruindo a bomba quando a pressão do sistema atinge o valor ajustado.

  2. Detecção de Carga (Controle de Fluxo): Ajusta automaticamente o deslocamento para manter um diferencial de pressão constante (Δp, normalmente ~14 bar) através de um orifício a jusante, fornecendo controle de fluxo independente da carga para melhorar a eficiência energética.

P2: O que indica o sufixo "VPA42N00"?

UM:Este código define a configuração mecânica:

  • V:FKM (Viton)selos, oferecendo resistência química e à temperatura superior.

  • P: Padrãoeixo chave paralelo(DIN 6885).

  • A42:Código de tamanho da porta 42(Portas de flange SAE com roscas métricas).

  • N00:Sem passagem(extremidade do eixo sólida, não é possível montar bombas adicionais no eixo).

Q3: Qual é a principal diferença entre este A10VSO71 e o A10VSO45 mencionado anteriormente?

UM:A principal diferença é atamanho do deslocamento:

  • A10VSO71: 71 cm³/rev, proporcionando maior vazão (~156 L/min vs ~117 L/min na mesma velocidade).

  • A10VSO45: 45 cm³/rot, tamanho menor para menores necessidades de vazão.

    Ambos compartilham o mesmo tipo de controle DFR1 e design da Série 31.

Q4: Para que são utilizadas as portas X e L?

UM:​

  • Porta X (Controle):Feedback de detecção de carga (LS). Ele se conecta ao sistema a jusante para detectar a pressão de carga, permitindo que a bomba ajuste seu deslocamento para manter o Δp ajustado.

  • Porta L (dreno da caixa):Deve ser conectado diretamente ao tanque. Ele alivia a pressão de vazamento interna para proteger a vedação do eixo (contrapressão máxima normalmente 0,5-2 bar).

Q5: Esta bomba pode ser usada em um sistema de circuito fechado?

UM:​Não.​ O A10VSO DFR1 foi projetado exclusivamente paraaplicações de circuito aberto(bomba → válvula → atuador → tanque). Para transmissões hidrostáticas de circuito fechado, você precisaria de uma unidade da série A4VG ou A2FM.

Contacto
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Pessoa de Contato: Mr. liyun

Telefone: +8615280488899

Envie sua pergunta diretamente para nós (0 / 3000)