logo
Casa ProdutosValva de serviço MOOG

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Estou Chat Online Agora

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel
Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Imagem Grande :  Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Detalhes do produto:
Lugar de origem: alemão
Marca: MOOG
Certificação: ISO
Número do modelo: D634-1019 D634-1023 D634-1024 D634-1025 D634-1026 D634-1027 D634-1028 D634-1029 D634-1031 D634-1032
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 1
Preço: 2
Detalhes da embalagem: Caixa de madeira
Tempo de entrega: 2 semanas
Termos de pagamento: MoneyGram, Western Union, T/T, D/P, D/A, L/C.
Habilidade da fonte: 30

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

descrição
Estrutura: Bomba de pistão Depois de seri: vídeo online
Origem: CHINA Porta: Foshan, China
Selo: Lip ou Mecânico Combustível: óleo hidráulico
Tipo: Bomba de pistão axial Rotação: 0,2-cp pode ser transportado ao contrário
Posição do eixo da bomba: horizontal Aplicação: Máquinas móveis e industriais
Doença: Princípio de malha interna
Destacar:

Axial Piston Pump Structure Moog Servo Valve

,

Hydraulic Oil Fuel Electro Hydraulic Servo Valve

,

25cm Nominal Diameter Proportional Flow Control Valve

MOOG D634 Series Electric Hydraulic Servo Valve
Product Description

Original MOOG German hydraulic servo valves including models D634-1019 through D634-1032. High-performance electric hydraulic servo valves designed for precision control in industrial applications.

Technical Specifications
Specification Value
Nominal Diameter 25cm
Material Cast Iron
Place of Origin Germany
Functional Purpose Building Materials Industry
Operating Temperature 36°C
Customization Available Yes
Imported Yes
Available Models

D634-1019, D634-1023, D634-1024, D634-1025, D634-1026, D634-1027, D634-1028, D634-1029, D634-1031, D634-1032

Related Models

D633-308BR08KO1M0NSM2, D633-313BR16K01M0NSM2, D633-317B, D633-380B, D633-460B, D633-473BR08KO1F0VSX2, D633-500B, D633-7205, D633-7369, D633-E714A, D634-319CR40KO2M0NSP2, D634-341C, D634-371C, D634-381CR24K02MOVSP2, D634-501AR40KO2M0NSM2, D634-514A, D634-514C, D661-4070, D661-4108, D661-4209, D661-4303EG75JOCA6VSX2HA, D661-4359CG35J0AA5VSX2HA, D661-4443CG45JOAA6VSX2HA, D661-4444CG60JOAA6VSX2HA, D661-4455EG35H0C06VSX2HA, D661-4469CG75JOAA6VSX2HA+B97007-061, D661-4495E, D661-4506CG23JOAA6VSX2HA, D661-4538C, D661-4539C, D661-4546C, D661-4561C, D661-4577CG45H0AA4VSX2HA, D661-4591E G45HOCA4VSX2HO, D661-4636 G60KOAA5VSX2HA, D661-4651, D661-4652, G631-3016B, D661-4697C, D661-4770, D661-4900P60HAAM4VSX2-A, D661-4923P80HAAM7NSX2-A, D661-6428EG15KBC06NSX2HA, D661-6460C, D662-4010, D662-4014D01JABF6VSX2-A, D662-4049, D662-4069B, D662-4308K, D662-Z4334KP01JOMF6VSX2-A, D663-4007L03HABD6VSX2-A, D663Z4305KP03JXNF6VSX2-A, D663Z4323KP03JONF6VSX2-A, D664-P05JAMO5NSX2-O, D665-4753P15HAJM6SEA2-E, D691-072D-6, D761-4361BS63KOGA5VPL, D765-1099G, D791-4028S25JOQB6VSX2-B, D791-5017, D951-2105-10HPR18A1RKP019SM28F1Z00, D952-2009-10, D956-2003-10, D957-2003-10HPR18A7RPK140TM28R1Z00, G122-829A001, G631-3002B, G631-3016B, G631-3003AH20JOFM4VBR, G631-3004BH40J0FM4VBR, G631-3006BH75JOFM4VBR, G631-3008B, G761-3001B, G761-3002BH10JOFM4VPL, G761-3003BH19JOGM4VPL, G761-3004B, G761-3005BS63JOGM4VPL, G761-3008B, G761-3006B, G761-3007B, G761-3009B, G761-3033B

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel 0
Installation Requirements
  • Filtration: Install a precision filter with a rating of 5 microns or less upstream of the servo valve
  • System Flushing: Thoroughly flush the entire hydraulic system before installation
  • Mounting: Can be mounted in any orientation with proper port alignment
  • Connections: Use O-ring seal connections (SAE J1926)
Troubleshooting Guide
Symptom Possible Cause
Servovalve does not follow input command 1. Open coil or coil leads
2. Clogged inlet filter
Poor response 1. Clogged inlet orifices or nozzles
2. Partially clogged filter
3. "Sticky" spool
No response to electrical signal Shorted coil assembly
Low flow gain 1. Incorrect null adjustment
2. Partially plugged orifice or filter
Maintenance Requirements
  • Maintain hydraulic fluid cleanliness (ISO DIS 4406 Code 16/13 maximum)
  • Change oil every six months
  • Maintain oil temperature between 40°C to 50°C
  • Regular inspection, cleaning and lubrication
For inquiries: WhatsApp +85267220981

Contacto
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Pessoa de Contato: Mr. liyun

Telefone: +8615280488899

Envie sua pergunta diretamente para nós (0 / 3000)