logo
Thuis ProductenMOOG-servo-klep

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Ik ben online Chatten Nu

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel
Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Grote Afbeelding :  Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

Productdetails:
Plaats van herkomst: duits
Merknaam: MOOG
Certificering: ISO
Modelnummer: D634-1019 D634-1023 D634-1024 D634-1025 D634-1026 D634-1027 D634-1028 D634-1029 D634-1031 D634-1032
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 1
Prijs: 2
Verpakking Details: Houten doos
Levertijd: 2 weken
Betalingscondities: MoneyGram, Western Union, T/T, D/P, D/A, L/C
Levering vermogen: 30

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel

beschrijving
Structuur: Zuigerpomp Na Serive: Online video
Oorsprong: CHINA Haven: Foshan, China
Zegel: Lip of mechanisch Brandstof: hydraulische olie
Type: Axiale zuigerpomp Rotatie: 0,2-CP kan omgekeerd worden getransporteerd
Pompas positie: horizontaal Toepassing: Mobiele en industriële machines
Voorwaarde: Intern meshing -principe
Markeren:

Axial Piston Pump Structure Moog Servo Valve

,

Hydraulic Oil Fuel Electro Hydraulic Servo Valve

,

25cm Nominal Diameter Proportional Flow Control Valve

MOOG D634 Series Electric Hydraulic Servo Valve
Product Description

Original MOOG German hydraulic servo valves including models D634-1019 through D634-1032. High-performance electric hydraulic servo valves designed for precision control in industrial applications.

Technical Specifications
Specification Value
Nominal Diameter 25cm
Material Cast Iron
Place of Origin Germany
Functional Purpose Building Materials Industry
Operating Temperature 36°C
Customization Available Yes
Imported Yes
Available Models

D634-1019, D634-1023, D634-1024, D634-1025, D634-1026, D634-1027, D634-1028, D634-1029, D634-1031, D634-1032

Related Models

D633-308BR08KO1M0NSM2, D633-313BR16K01M0NSM2, D633-317B, D633-380B, D633-460B, D633-473BR08KO1F0VSX2, D633-500B, D633-7205, D633-7369, D633-E714A, D634-319CR40KO2M0NSP2, D634-341C, D634-371C, D634-381CR24K02MOVSP2, D634-501AR40KO2M0NSM2, D634-514A, D634-514C, D661-4070, D661-4108, D661-4209, D661-4303EG75JOCA6VSX2HA, D661-4359CG35J0AA5VSX2HA, D661-4443CG45JOAA6VSX2HA, D661-4444CG60JOAA6VSX2HA, D661-4455EG35H0C06VSX2HA, D661-4469CG75JOAA6VSX2HA+B97007-061, D661-4495E, D661-4506CG23JOAA6VSX2HA, D661-4538C, D661-4539C, D661-4546C, D661-4561C, D661-4577CG45H0AA4VSX2HA, D661-4591E G45HOCA4VSX2HO, D661-4636 G60KOAA5VSX2HA, D661-4651, D661-4652, G631-3016B, D661-4697C, D661-4770, D661-4900P60HAAM4VSX2-A, D661-4923P80HAAM7NSX2-A, D661-6428EG15KBC06NSX2HA, D661-6460C, D662-4010, D662-4014D01JABF6VSX2-A, D662-4049, D662-4069B, D662-4308K, D662-Z4334KP01JOMF6VSX2-A, D663-4007L03HABD6VSX2-A, D663Z4305KP03JXNF6VSX2-A, D663Z4323KP03JONF6VSX2-A, D664-P05JAMO5NSX2-O, D665-4753P15HAJM6SEA2-E, D691-072D-6, D761-4361BS63KOGA5VPL, D765-1099G, D791-4028S25JOQB6VSX2-B, D791-5017, D951-2105-10HPR18A1RKP019SM28F1Z00, D952-2009-10, D956-2003-10, D957-2003-10HPR18A7RPK140TM28R1Z00, G122-829A001, G631-3002B, G631-3016B, G631-3003AH20JOFM4VBR, G631-3004BH40J0FM4VBR, G631-3006BH75JOFM4VBR, G631-3008B, G761-3001B, G761-3002BH10JOFM4VPL, G761-3003BH19JOGM4VPL, G761-3004B, G761-3005BS63JOGM4VPL, G761-3008B, G761-3006B, G761-3007B, G761-3009B, G761-3033B

Moog Servo Valve with Axial Piston Pump Structure and 25cm Nominal Diameter for Hydraulic Oil Fuel 0
Installation Requirements
  • Filtration: Install a precision filter with a rating of 5 microns or less upstream of the servo valve
  • System Flushing: Thoroughly flush the entire hydraulic system before installation
  • Mounting: Can be mounted in any orientation with proper port alignment
  • Connections: Use O-ring seal connections (SAE J1926)
Troubleshooting Guide
Symptom Possible Cause
Servovalve does not follow input command 1. Open coil or coil leads
2. Clogged inlet filter
Poor response 1. Clogged inlet orifices or nozzles
2. Partially clogged filter
3. "Sticky" spool
No response to electrical signal Shorted coil assembly
Low flow gain 1. Incorrect null adjustment
2. Partially plugged orifice or filter
Maintenance Requirements
  • Maintain hydraulic fluid cleanliness (ISO DIS 4406 Code 16/13 maximum)
  • Change oil every six months
  • Maintain oil temperature between 40°C to 50°C
  • Regular inspection, cleaning and lubrication
For inquiries: WhatsApp +85267220981

Contactgegevens
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contactpersoon: Mr. liyun

Tel.: +8615280488899

Direct Stuur uw aanvraag naar ons (0 / 3000)