Szczegóły Produktu:
Miejsce pochodzenia: Niemcy
Nazwa handlowa: Rexroth
Orzecznictwo: ISO
Numer modelu: R901436328 2WFCE50S1500L-1X/M/24G1
Zapłata:
Minimalne zamówienie: 1
Szczegóły pakowania: drewniane pudełko
Czas dostawy: 2 tygodnie
Zasady płatności: Western Union, T/T, D/P, D/A, L/C
Możliwość Supply: 100

R901436328 2WFCE50S1500L-1X/M/24G1 Hydraulic proportional flow control valve Rexroth Germany

Opis
Producent/seria​: Seria Rexroth 2WFCE Kod zamówienia: R901436328
Pełny model: 2WFCE50S1500L-1X/M/24G1 Funkcja podstawowa: Proporcjonalne dławienie / kontrola przepływu przy wysokim przepływie; może służyć jako zawór kierun
Maks. Ciśnienie robocze: 420 barów (porty A, B)
Podkreślić:

Rexroth hydraulic flow control valve

,

proportional hydraulic valve Germany

,

Rexroth 2WFCE50S1500L valve

Parameter

Specification

Manufacturer / Series

Rexroth 2WFCE Series

Order Code

R901436328

Full Model

2WFCE50S1500L-1X/M/24G1

Valve Type

Pilot-Operated Proportional Directional Cartridge Valve (2/2-way)

Primary Function

High-flow proportional throttling / flow control; can be used as a directional valve.

Control Type

Proportional solenoid with Integrated Electronics (OBE)​ and position feedback.

Nominal Size

NG 50 (Cartridge size per ISO 7368)

Max. Operating Pressure

420 bar (Ports A, B)

Rated Flow (Qn)

1500 L/min (at Δp = 5 bar)

Flow Characteristic

Linear (L)

Pressure Compensation

No (Requires external pressure compensator for load-independent flow control).

Ports

A, B, X (Pilot), Y (Drain)

Mounting

Cartridge Insert (Cavity per ISO 7368)

Electrical Connection

Multi-pin connector (Integrated electronics)

Supply Voltage

24 V DC (Integrated electronics, no external amplifier needed)

Command Signal

4–20 mA (Analog input, corresponds to 0–100% valve opening)

Seal Material

NBR (Standard for mineral oils)

Hydraulic Fluid

Mineral oils (HL, HLP), HETG, HEES, HFDU

Operating Temperature

-20°C to +60°C

Weight

Approx. 10.8 kg

Country of Origin

Germany

R901436328 2WFCE50S1500L-1X/M/24G1  Hydraulic proportional flow control valve R</p>
<table style= R900938035 2FRE6B-2X/2QEK4MV R900954501 2FRE6B-2X/2QEK4RV R900933708 2FRE6B-2X/3QK4MV R900937872 2FRE6B-2X/3QK4RV R900937873 2FRE6B-2X/6QK4MV R900949742 2FRE6B-2X/6QK4RV R900937874 2FRE6B-2X/8LK4MV R900934070 2FRE6B-2X/8LK4RV 811403013 2FREX10B-1X/70L1G24-25N9Z4MM 811403123 2FREX6B-1X/15L1G24-25N9Z4MM 811403119 2FREX6B-1X/35L1G24-25N9Z4MM-254 811403118 2FREX6B-1X/7,5L1G24-25N9Z4MM-254 R900424887 2FRM10-3X/10L R900423250 2FRM10-3X/10LB R900427774 2FRM10-3X/10LV R900423251 2FRM10-3X/16L R900423252 2FRM10-3X/16LB R900423253 2FRM10-3X/16LV R900915817 2FRE10-4X/10LBK4M R900785983 2FRE10-4X/10LBK4V R900953546 2FRE10-4X/10LK4M R900949575 2FRE10-4X/10QBK4M R900963211 2FRE10-4X/10QK4M R900915825 2FRE10-4X/16LBK4M R900760386 2FRE10-4X/16LBK4V R900959337 2FRE10-4X/16LK4M R900976050 2FRE10-4X/16LK4V R900245908 2FRE10-4X/16QBK4M R900768728 2FRE10-4X/16QK4M R900915820 2FRE10-4X/25LBK4M R900249888 2FRE10-4X/25LBK4V R900932728 2FRE10-4X/25LK4M R900962961 2FRE10-4X/25QBK4M R900948692 2FRE10-4X/25QK4M R900764820 2FRE10-4X/2QEBK4M R900963481 2FRE10-4X/2QEK4M R900915815 2FRE10-4X/50LBK4M R901021448 2FRE10-4X/50LBK4V R900915813 2FRE10-4X/50LK4M R900244809 2FRE10-4X/50LK4V R900931237 2FRE10-4X/5LBK4M R900942938 2FRE10-4X/5LK4M R900962409 2FRE10-4X/5LK4V R900946937 2FRE10-4X/5QBK4M R900964806 2FRE10-4X/5QEBK4M R900962277 2FRE10-4X/5QEK4M R900915823 2FRE10-4X/60LBK4M R900976616 2FRE10-4X/60LBK4V R900915821 2FRE10-4X/60LK4M R900973066 2FRE10-4X/60LK4V R900915819 2FRE16-4X/100LBK4M R900785982 2FRE16-4X/100LBK4V R900915822 2FRE16-4X/100LK4M R900721995 2FRE16-4X/100LK4V R900927478 2FRE16-4X/125LBK4M R901040916 2FRE16-4X/125LBK4V R900915824 2FRE16-4X/125LK4M R900915814 2FRE16-4X/160LBK4M R900747708 2FRE16-4X/160LBK4V R900915816 2FRE16-4X/160LK4M R900973515 2FRE16-4X/160LK4V R900962297 2FRE16-4X/60LBK4M R900927479 2FRE16-4X/80LBK4M R901070659 2FRE16-4X/80LBK4V

Frequently Asked Questions (FAQ)

Q1: What is the key difference between the 2WFCE50 and the smaller 2WFCE40?

A:​ The primary difference is the size and flow capacity. The 2WFCE50​ (NG50) is designed for extremely high-flow systems (1500 L/min), making it suitable for massive presses, rolling mills, or marine equipment. It shares the same 420 bar pressure rating and OBE design but requires a larger ISO 7368 cavity.

Q2: Does this valve include built-in pressure compensation?

A:No.​ The 2WFCE50S1500L is a proportional directional/throttling valve. It does not​ have a built-in pressure compensator. To achieve load-independent flow control, you must install a separate pressure compensator​ (e.g., an FD-type pressure compensator) upstream or downstream of this valve.

Q3: What does the "24G1" suffix indicate?

A:24G1​ specifies the electrical interface:

  • 24: 24 V DC supply voltage.

  • G1: Analog command input of 4–20 mA​ (current signal). This interface also provides a "Ready" signal output for monitoring the valve's electronic status.

Q4: What happens if power is lost or the cable breaks?

A:​ The valve has a fail-safe closed​ function. If the supply voltage fails or drops below the threshold, or if the solenoid cable breaks, the main stage spool is pushed to its seat by spring force and system pressure, blocking flow between ports A and B.

Q5: What is the purpose of the X and Y ports?

A:Port X​ is the pilot supply​ port. It must be connected to a pressurized oil source (often from port A or B, or an external source) to operate the pilot stage. Port Y​ is the drain port​ for the pilot control oil and must be connected directly to the tank with minimal backpressure.