Szczegóły Produktu:
|
| Producent/seria: | Seria Rexroth 2WFCE | Kod zamówienia: | R901436328 |
|---|---|---|---|
| Pełny model: | 2WFCE50S1500L-1X/M/24G1 | Funkcja podstawowa: | Proporcjonalne dławienie / kontrola przepływu przy wysokim przepływie; może służyć jako zawór kierun |
| Maks. Ciśnienie robocze: | 420 barów (porty A, B) | ||
| Podkreślić: | Rexroth hydraulic flow control valve,proportional hydraulic valve Germany,Rexroth 2WFCE50S1500L valve |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth 2WFCE Series |
|
Order Code |
R901436328 |
|
Full Model |
2WFCE50S1500L-1X/M/24G1 |
|
Valve Type |
Pilot-Operated Proportional Directional Cartridge Valve (2/2-way) |
|
Primary Function |
High-flow proportional throttling / flow control; can be used as a directional valve. |
|
Control Type |
Proportional solenoid with Integrated Electronics (OBE) and position feedback. |
|
Nominal Size |
NG 50 (Cartridge size per ISO 7368) |
|
Max. Operating Pressure |
420 bar (Ports A, B) |
|
Rated Flow (Qn) |
1500 L/min (at Δp = 5 bar) |
|
Flow Characteristic |
Linear (L) |
|
Pressure Compensation |
No (Requires external pressure compensator for load-independent flow control). |
|
Ports |
A, B, X (Pilot), Y (Drain) |
|
Mounting |
Cartridge Insert (Cavity per ISO 7368) |
|
Electrical Connection |
Multi-pin connector (Integrated electronics) |
|
Supply Voltage |
24 V DC (Integrated electronics, no external amplifier needed) |
|
Command Signal |
4–20 mA (Analog input, corresponds to 0–100% valve opening) |
|
Seal Material |
NBR (Standard for mineral oils) |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HETG, HEES, HFDU |
|
Operating Temperature |
-20°C to +60°C |
|
Weight |
Approx. 10.8 kg |
|
Country of Origin |
Germany |
Q1: What is the key difference between the 2WFCE50 and the smaller 2WFCE40?
A: The primary difference is the size and flow capacity. The 2WFCE50 (NG50) is designed for extremely high-flow systems (1500 L/min), making it suitable for massive presses, rolling mills, or marine equipment. It shares the same 420 bar pressure rating and OBE design but requires a larger ISO 7368 cavity.
Q2: Does this valve include built-in pressure compensation?
A: No. The 2WFCE50S1500L is a proportional directional/throttling valve. It does not have a built-in pressure compensator. To achieve load-independent flow control, you must install a separate pressure compensator (e.g., an FD-type pressure compensator) upstream or downstream of this valve.
Q3: What does the "24G1" suffix indicate?
A: 24G1 specifies the electrical interface:
24: 24 V DC supply voltage.
G1: Analog command input of 4–20 mA (current signal). This interface also provides a "Ready" signal output for monitoring the valve's electronic status.
Q4: What happens if power is lost or the cable breaks?
A: The valve has a fail-safe closed function. If the supply voltage fails or drops below the threshold, or if the solenoid cable breaks, the main stage spool is pushed to its seat by spring force and system pressure, blocking flow between ports A and B.
Q5: What is the purpose of the X and Y ports?
A: Port X is the pilot supply port. It must be connected to a pressurized oil source (often from port A or B, or an external source) to operate the pilot stage. Port Y is the drain port for the pilot control oil and must be connected directly to the tank with minimal backpressure.
Osoba kontaktowa: Mr. liyun
Tel: +8615280488899