logo
제품 소개렉스트로 수압 밸브

R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth

제가 지금 온라인 채팅 해요

R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth

R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth
R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth

큰 이미지 :  R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth

제품 상세 정보:
원래 장소: 독일 사람
브랜드 이름: Rexroth
인증: ISO
모델 번호: R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00
결제 및 배송 조건:
최소 주문 수량: 1
포장 세부 사항: 나무 상자
배달 시간: 2주
지불 조건: 서부 동맹, T/T, D/P, D/A, L/C
공급 능력: 100

R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing valve Rexroth

설명
최대. 작동 압력​: 100bar(포트 P, A, B) 최대. 유량​: 15L/분(Δp = 50bar)
조정 가능한 압력 범위​: 0 – 25bar(신호에 비례) 제어 유형​: 전자 장치가 통합된 비례 솔레노이드(OBE)​
명령 신호​: ±10V(A1)

Parameter

Value / Description

Order Code

R900930264

Model

3DREPE6C-2X=25EG24N9K31/A1V=00

Type

Direct-operated proportional pressure reducing valve (3-way)

Size

NG6 (CETOP 3)

Max. Operating Pressure

100 bar (Ports P, A, B)

Max. Flow Rate

15 L/min (Δp = 50 bar)

Adjustable Pressure Range

0 – 25 bar (proportional to signal)

Mounting

Subplate (ISO 4401-03-02-0-05)

Control Type

Proportional solenoid with integrated electronics (OBE)

Supply Voltage

24 V DC

Command Signal

±10 V (A1)

Electrical Connector

7-pin (6+PE) per EN 175201-804 (K31)

Manual Override

Yes, concealed (N9)

Seals

FKM (Viton®)​ (V)

Weight

Approx. 2.2 kg

R900930264 3DREPE6C-2X=25EG24N9K31/A1V=00 German hydraulic proportional pressure reducing</p>
<table style= 3DREP6B-2X/25EG24N9K4/M 3DREP6B-2X/25EG24NJK31/M 3DREP6B-2X/45EG24K4/M 3DREP6B-2X/45EG24N9K4/M 3DREP6C-2X/16EG24K4/V 3DREP6C-2X/16EG24K4/M 3DREP6C-2X/16EG24N9K4/V 3DREP6C-2X/16EG24N9K4/M 3DREP6C-2X/25EG24K4/V 3DREP6C-2X/25EG24K4/M 3DREP6C-2X/25EG24N9K4/V 3DREP6C-2X/25EG24N9K4/M 3DREP6C-2X/25EG24JK31/V 3DREP6C-2X/25EG24JK31/M 3DREP6C-2X/25EG24NJK31/V 3DREP6C-2X/25EG24NJK31/M 3DREP6C-2X/45EG24K4/M 3DREP6C-2X/45EG24N9K4/V 3DREP6C-2X/45EG24N9K4/M 3DREP6C-2X/45EG24JK31/M 3DREPE6A-2X/16EG24K31/A1M 3DREPE6A-2X/16EG24N9K31/A1M 3DREPE6A-2X/25EG24K31/A1V 3DREPE6A-2X/25EG24K31/A1M 3DREPE6A-2X/25EG24N9K31/A1V 3DREPE6A-2X/25EG24N9K31/A1M 3DREPE6A-2X/45EG24K31/A1V 3DREPE6A-2X/45EG24K31/A1M 3DREPE6A-2X/45EG24N9K31/A1V 3DREPE6A-2X/45EG24N9K31/A1M 3DREPE6B-2X/25EG24K31/A1V 3DREPE6B-2X/25EG24K31/A1M 3DREPE6B-2X/25EG24N9K31/A1V 3DREPE6B-2X/25EG24N9K31/A1M 3DREPE6B-2X/45EG24N9K31/A1V 3DREPE6B-2X/45EG24N9K31/A1M 3DREPE6C-2X/16EG24K31/A1M 3DREPE6C-2X/16EG24N9K31/A1V 3DREPE6C-2X/16EG24N9K31/A1M 3DREPE6C-2X/25EG24K31/A1V 3DREPE6C-2X/25EG24K31/A1M 3DREPE6C-2X/25EG24N9K31/A1V 3DREPE6C-2X/25EG24N9K31/A1M 3DREPE6C-2X/25EG24NJK31/A1M 3DREPE6C-2X/45EG24K31/A1M 3DREPE6C-2X/45EG24N9K31/A1V 3DREPE6C-2X/45EG24N9K31/A1M 3DREPE6C-2X/45EG24NJK31/A1M 3DRE10P-6X/100YG24K4V 3DRE10P-6X/100XYG24K4V 3DRE10P-6X/200YG24K4V 3DRE10P-6X/200XYG24K4V 3DRE10P-6X/315YG24K4V 3DRE10P-6X/315XYG24K4V 3DREM10P-6X/50YG24K4V 3DREM10P-6X/100YG24K4V 3DREM10P-6X/100XYG24K4V 3DREM10P-6X/200YG24K4V 3DREM10P-6X/200XYG24K4V 3DREM10P-6X/315YG24K4V 3DREM10P-6X/315XYG24K4V 3DREE10P-6X/50YG24K31V 3DREE10P-6X/100YG24K31V 3DREE10P-6X/100XYG24K31V 3DREE10P-6X/200YG24K31V 3DREE10P-6X/200XYG24K31V 3DREE10P-6X/315YG24K31V 3DREE10P-6X/315XYG24K31V 3DREME10P-6X/50YG24K31V

FAQ: Rexroth 3DREPE6C-2X/25EG24N9K31/A1V

What is this valve?

It is a direct-operated, 3-way proportional pressure reducing valve with integrated electronics (OBE). It converts an electrical input signal into a precisely controlled, reduced hydraulic pressure for pilot or secondary circuits.

What are its key features?

  • Integrated Electronics (OBE):​ The amplifier is built into the solenoid, eliminating the need for an external amplifier card.

  • 3-Way Function:​ Can reduce pressure (P→A/B) or relieve pressure (A/B→T) based on the solenoid actuation.

  • High-Temp Seals:​ Equipped with FKM (Viton®) seals​ for use with phosphate ester fluids or in high-temperature environments.

  • Manual Override:​ Includes a concealed manual override (N9) for testing or emergency operation without electrical power.

How does it work?

The electrical command signal (±10V) controls the solenoid force. This force sets the reduced outlet pressure proportionally. When de-energized, the valve center position connects the outlet ports (A, B) to the tank (T) for safe pressure release.

Where is it typically used?

Commonly used in low-pressure pilot circuits, clamping applications, and secondary circuit pressure regulation where precise, variable control and compact design are required (e.g., machine tools, test stands).

How do I wire it?

  • Power & Signal:​ Supply 24V DC and the ±10V command signal directly to the 7-pin connector on the valve (no external amplifier needed).

  • Drain:​ Ensure the tank port (T) is connected directly to the reservoir with minimal backpressure.

What if the pressure is unstable or incorrect?

  • Verify the ±10V command signal is stable and within range.

  • Check for contamination, as the small orifices in direct-acting valves are highly sensitive to dirt.

  • Ensure the inlet pressure (P) is stable and significantly higher than the desired reduced pressure.

  • Confirm the tank line (T) is not blocked and has low backpressure.