Detail produk:
|
| Maks. Aliran: | ~156 L/mnt (pada 2200 rpm, teoritis) | Maks. Kecepatan: | 2200 rpm (pada perpindahan penuh) |
|---|---|---|---|
| Flensa Pemasangan: | ISO 3019-2 / SAE J744 2 baut | Ukuran Pelabuhan: | Kode 42 (port flensa SAE, ulir UNC) |
| Tekanan Puncak: | 350 bar (intermiten) |
|
Parameter |
Spesifikasi |
|---|---|
|
Pabrikan / Seri |
Rexroth A10VSO Seri 31 |
|
Kode Pesanan |
R902482660 |
|
Model Lengkap |
AA10VSO71DR/31R-VPA42N00 |
|
Tipe Pompa |
Pompa Variabel Piston Aksial (Desain Swashplate, Sirkuit Terbuka) |
|
Tipe Kontrol |
dr (Kontrol Tekanan / Kompensator Tekanan) |
|
Maks. Pemindahan |
71 cm³/putaran |
|
Tekanan Nominal |
280 batang |
|
Tekanan Puncak |
350 bar (intermiten) |
|
Ukuran Nominal |
NG 71 |
|
Arah Rotasi |
Sebelah kanan (R, dilihat dari ujung poros) |
|
Tipe Poros |
Poros meruncing 1:5 dengan kunci paralel (DIN 6885) |
|
Pelabuhan |
S (Hisap), B (Tekanan), L (Pembuangan Kotak) |
|
Ukuran Pelabuhan |
Kode 42 (port flensa SAE, ulir UNC) |
|
Flensa Pemasangan |
ISO 3019-2 / SAE J744 2 baut |
|
Maks. Kecepatan |
2200 rpm (pada perpindahan penuh) |
|
Maks. Mengalir |
~156 L/mnt (pada 2200 rpm, teoritis) |
|
Bahan Segel |
FKM (Viton) |
|
Cairan Hidraulik |
Minyak mineral (HL, HLP), HETG, HEES, HFDU |
|
Suhu Operasional |
-20°C hingga +80°C |
|
Berat |
Kira-kira. 35,2kg |
|
Negara Asal |
Jerman |
![]()
| R910948800 A A10VSO 71 DSLR/31R-PPA12K00 -SO290 |
| R910947239 A A10VSO 71 DSLR/31R-PPA12K01 |
| R910944067 A A10VSO 71 DSLR/31R-PPA12N00 |
| R910946787 A A10VSO 71 DFR /31L-PPA12N00 |
| R910960472 A A10VSO 71 DFR /31R-PPA12K01 |
| R910963914 A A10VSO 71 DFR /31R-PPA12K02 |
| R902416246 A A10VSO 71 DFR /31R-PPA12K07 |
| R902428830 A A10VSO 71 DFR /31R-PPA12K52 |
| R910942635 A A10VSO 71 DFR /31R-PPA12N00 |
| R902439238 A A10VSO 71 DFR /31R-PSA12K07 -S1627 |
| R910960746 A A10VSO 71 DFR1/31L-PPA12N00 |
| R910947985 A A10VSO 71 DFR1/31R-PPA12K01 |
| R910947872 A A10VSO 71 DFR1/31R-PPA12K02 |
| R910966909 A A10VSO 71 DFR1/31R-PPA12K04 |
| R910963378 A A10VSO 71 DFR1/31R-PPA12K07 |
| R910991723 A A10VSO 71 DFR1/31R-PPA12KB3 |
| R910978724 A A10VSO 71 DFR1/31R-PPA12KB4 |
| R910968700 A A10VSO 71 DFR1/31R-PPA12KB5 |
| R910944440 A A10VSO 71 DFR1/31R-PPA12N00 |
| R910947992 A A10VSO 71 DFR1/31R-PPA12N00 -JADI 20 |
| R910968701 A A10VSO 71 DFR1/31R-PSA12N00 |
| R910986932 A A10VSO 71 DFR1/31R-VPA12K01 |
| R910992519 A A10VSO 71 DFR1/31R-VPA12N00 |
| R902473183 A A10VSO 71 DFR1/31R-VPA42K27 |
| R902488176 A A10VSO 71 DFR1/31R-VPA42KB5 -JADI 52 |
| R902501568 A A10VSO 71 DFR1/31R-VSA12N00 |
| R910960333 A A10VSO 71 DR /31L-VPA12N00 |
| R910998793 A A10VSO 71 DR /31R-PPA12N00 -SO108 |
| R910947219 A A10VSO 71 DR /31R-VPA12N00 |
| R902473969 A A10VSO 71 DR /31R-VPA42KB5 |
| R902482660 A A10VSO 71 DR /31R-VPA42N00 |
| R910947898 A A10VSO 71 DRG /31R-PPA12N00 |
| R910992951 A A10VSO 71 DRG /31R-PSA12N00 |
| R902411494 A A10VSO 71 DRG /31R-VPA12K02 |
| R910947258 A A10VSO 71 DRG /31R-VPA12N00 |
| R902452789 A A10VSO 71 DRS /32R-VPB22U99 |
| R902486410 A A10VSO 71 DRS /32R-VRB32U01 -JADI 52 |
| R902486409 A A10VSO 71 DRS /32R-VRB32U68 -JADI 52 |
| R910961157 A A10VSO 71 FHD /31R-PPA12N00 |
| R902460926 A A10VSO100 DFLR/31R-VPA12N00 |
| R910907813 A A10VSO100 DFR /31L-PPA12N00 |
| R910917313 A A10VSO100 DFR /31R-PPA12K01 |
| R910998331 A A10VSO100 DFR /31R-PPA12K07 |
| R910942637 A A10VSO100 DFR /31R-PPA12K27 |
| R902417327 A A10VSO100 DFR /31R-PPA12KB4 |
| R902416469 A A10VSO100 DFR /31R-PPA12KB5 |
| R910939643 A A10VSO100 DFR /31R-PPA12N00 |
| R910991002 A A10VSO100 DFR /31R-PSA12N00 |
| R910920969 A A10VSO100 DFR /31R-VPA12N00 |
| R910986270 A A10VSO100 DFR1/31L-PPA12KB4 -JADI 32 |
| R910911394 A A10VSO100 DFR1/31R-PPA12K01 |
| R910927083 A A10VSO100 DFR1/31R-PPA12K02 |
| R910983124 A A10VSO100 DFR1/31R-PPA12KB3 |
Q1: Apa fungsi kontrol "DR"?
A: Itudradalah aKompensator Tekanan. Secara otomatis mengurangi perpindahan pompa (destroke) ketika tekanan sistem mencapai nilai yang telah ditentukan. Ini mempertahankan tekanan konstan sekaligus meminimalkan konsumsi energi dan pembangkitan panas.
Q2: Apa yang ditunjukkan oleh akhiran "VPA42N00"?
A: Kode ini mendefinisikan konfigurasi mekanis:
V:FKM (Viton)segel untuk suhu tinggi dan ketahanan kimia.
P:Poros meruncing (1:5) dengan kunci paralel.
A42:Kode ukuran port 42 (Port flensa SAE dengan ulir UNC).
N00:Tidak ada drive-through(ujung poros padat).
Q3: Apa perbedaan utama antara A10VSO71 ini dan A10VSO45 yang disebutkan sebelumnya?
A:Perbedaan utamanya adalahukuran perpindahan:
A10VSO71: 71 cm³/putaran, menghasilkan keluaran aliran yang lebih tinggi (~156 L/mnt vs ~117 L/mnt pada kecepatan yang sama).
A10VSO45: 45 cm³/rev, ukuran lebih kecil untuk kebutuhan aliran lebih rendah.
Model ini menggunakan yang lebih sederhanadr kontrol tekanan, sedangkan yang sebelumnya digunakanDFR1(tekanan + sensor beban).
Q4: Apa tujuan dari port L?
A: ItuPort L (Pembuangan Kasus)harus terhubung langsung ke tangki. Ini mengurangi tekanan kebocoran internal untuk melindungi segel poros. Tekanan balik maksimum yang diijinkan biasanya 2 bar.
Q5: Dapatkah pompa ini digunakan dalam sistem loop tertutup?
A:TIDAK. A10VSO DR dirancang khusus untukaplikasi sirkuit terbuka (pompa → katup → aktuator → tangki). Untuk transmisi hidrostatik loop tertutup, Anda memerlukan unit seri A4VG atau A2FM.