Produktdetails:
|
| Max. Fließen: | ~156 L/min (bei 2200 U/min, theoretisch) | Max. Geschwindigkeit: | 2200 U/min (bei vollem Hubraum) |
|---|---|---|---|
| Montageflansch: | ISO 3019-2 / SAE J744 2-Loch | Portgröße: | Code 42 (SAE-Flanschanschlüsse, UNC-Gewinde) |
| Spitzendruck: | 350 bar (intermittierend) |
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth A10VSO Series 31 |
|
Order Code |
R902482660 |
|
Full Model |
AA10VSO71DR/31R-VPA42N00 |
|
Pump Type |
Axial Piston Variable Pump (Swashplate Design, Open Circuit) |
|
Control Type |
DR (Pressure Control / Pressure Compensator) |
|
Max. Displacement |
71 cm³/rev |
|
Nominal Pressure |
280 bar |
|
Peak Pressure |
350 bar (intermittent) |
|
Nominal Size |
NG 71 |
|
Rotation Direction |
Right-hand (R, viewed from shaft end) |
|
Shaft Type |
Tapered shaft 1:5 with parallel key (DIN 6885) |
|
Ports |
S (Suction), B (Pressure), L (Case Drain) |
|
Port Size |
Code 42 (SAE flange ports, UNC threads) |
|
Mounting Flange |
ISO 3019-2 / SAE J744 2-bolt |
|
Max. Speed |
2200 rpm (at full displacement) |
|
Max. Flow |
~156 L/min (at 2200 rpm, theoretical) |
|
Seal Material |
FKM (Viton) |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HETG, HEES, HFDU |
|
Operating Temperature |
-20°C to +80°C |
|
Weight |
Approx. 35.2 kg |
|
Country of Origin |
Germany |
Q1: What is the function of the "DR" control?
A: The DR is a Pressure Compensator. It automatically reduces the pump's displacement (destrokes) when the system pressure reaches the preset value. This maintains constant pressure while minimizing energy consumption and heat generation.
Q2: What does the "VPA42N00" suffix indicate?
A: This code defines the mechanical configuration:
V: FKM (Viton) seals for high temperature and chemical resistance.
P: Tapered shaft (1:5) with a parallel key.
A42: Port size code 42 (SAE flange ports with UNC threads).
N00: No through-drive (solid shaft end).
Q3: What is the key difference between this A10VSO71 and the previously mentioned A10VSO45?
A: The primary difference is the displacement size:
A10VSO71: 71 cm³/rev, providing higher flow output (~156 L/min vs ~117 L/min at same speed).
A10VSO45: 45 cm³/rev, smaller size for lower flow requirements.
This model uses a simpler DR pressure control, whereas the previous ones used DFR1 (pressure + load sensing).
Q4: What is the purpose of the L port?
A: The L Port (Case Drain) must be connected directly to the tank. It relieves internal leakage pressure to protect the shaft seal. Maximum allowable backpressure is typically 2 bar.
Q5: Can this pump be used in a closed-loop system?
A: No. The A10VSO DR is designed exclusively for open-circuit applications (pump → valve → actuator → tank). For closed-loop hydrostatic transmissions, you would need an A4VG or A2FM series unit.
Ansprechpartner: Mr. liyun
Telefon: +8615280488899