Produktdetails:
|
| Modell: | DREE20-6X/315YMG24K31A1M | Einstellbarer Druckbereich: | ~2 – 315 bar (elektrisch proportional, 0–10 V) |
|---|---|---|---|
| Max. Durchflusskapazität: | 300 l/min | Versorgungsspannung: | 24V DC (G24) |
| Medientemperatur: | -20°C bis +80°C |
|
Parameter |
Specification |
|---|---|
|
Order Number |
R901278310 |
|
Model |
DREE20-6X/315YMG24K31A1M |
|
Type |
Pilot-operated proportional pressure reducing valve (2-way, B→A) |
|
Function |
Reduces inlet pressure (B) to controlled secondary pressure (A); excess flow internally drained |
|
Nominal Size |
NG20 (CETOP 7, Size 20) |
|
Max. Operating Pressure |
Port A & B: 315 bar |
|
Adjustable Pressure Range |
~2 – 315 bar (Electrically proportional, 0–10V) |
|
Max. Flow Capacity |
300 L/min |
|
Pilot Flow Consumption |
Approx. 0.8 – 1.2 L/min (Internal pilot supply) |
|
Valve Design |
Pilot-operated spool valve, with integrated electronics (OBE) |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
0 – +10 V (A1) |
|
Electrical Connector |
6-pin + PE (K31) per DIN EN 175201-804 |
|
Special Features |
Integrated electronics (OBE), Mechanical max. pressure limiter (M), External pilot drain (Y), No check valve (M) |
|
Mounting Interface |
ISO 5781-AG-10-2-A (NG20 subplate) |
|
Seal Material |
NBR (M) |
|
Suitable Media |
Mineral oils (HL, HLP), HLP-D, HVLP, HFC fluids |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
15 – 380 mm²/s (recommended 30–46 mm²/s) |
|
Ambient Temperature |
-20°C to +50°C (electronics) |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Control Performance |
Hysteresis ≤ ±3.5 %, Repeat accuracy < ±2 % |
|
Weight |
Approx. 6.1 – 6.2 kg |
FAQ:
Integrated Electronics (OBE)
The "E" in DREE confirms On-Board Electronics (OBE). This means the valve contains its own amplifier. You supply 24V DC power and a 0–10 V command signal directly to the valve's K31 connector. This simplifies wiring and eliminates the need for an external VT-VSPA amplifier.
Mechanical Maximum Pressure Limiter (M)
The "M" immediately after DREE20 indicates the valve includes a mechanical safety relief valve as a maximum pressure limiter. This is a safety feature that hydraulically limits the maximum pressure at port A to approximately 350 bar, protecting the system in case of an electrical control fault.
High Pressure & Flow Rating (315 bar / 300 L/min)
The "315" denotes the maximum electrically adjustable reduced pressure at port A. This is the highest pressure variant in the DREE20 series, capable of handling flows up to 300 L/min, making it suitable for high-power industrial systems.
External Pilot Drain (Y) & No Check Valve
"Y": The pilot control oil must be drained externally via port Y. This port must be connected directly to the tank with minimal backpressure. High backpressure at Y will cause inaccurate pressure regulation.
"M" at the end: The suffix "M" indicates no check valve is included between ports A and B. This means flow from port A back to port B is blocked by the spool design. If your application requires free reverse flow (A→B), you would need a variant without the final "M" code.
Critical Installation Notes
Port Y Drain: Must be piped separately to tank with a line diameter ≥ 5 mm and length < 2.5 m to avoid backpressure issues.
Zero Signal Pressure: With a 0 V command signal, the valve maintains a minimum pressure of approximately 2 bar at port A.
Subplate: Requires an NG20 subplate according to ISO 5781-AG-10-2-A (e.g., Rexroth RE 45102 series).
Correction: Your description mentioned "proportional relief valve", but this model is specifically a proportional pressure reducing valve. It controls the downstream (A-port) pressure, not the system relief pressure.