Product Details:
|
| Weight: | Approx. 1.4 Kg | Mounting Bolts: | 4 × M5 (ISO 4762, Grade 10.9), Torque ~8–10 Nm Cross Pattern |
|---|---|---|---|
| Drain Requirement: | External Drain Port Y → Tank (dedicated Line, Zero Backpressure) | Adjustable Flow Range: | ~3 – 32 L/min (Code /32Q = Max. Flow 32 L/min — Special/extended Range For NG6)* |
| Max. Drain Pressure (Y-port): | 160 Bar (recommend Zero Backpressure To Tank) | ||
| Highlight: | Rexroth speed control valve,genuine Rexroth hydraulic valve,Rexroth 2FRM6A36-2X valve |
||
|
Parameter Category |
Parameter |
Specification |
|---|---|---|
|
General Information |
Brand / Model |
Rexroth (Germany), 2FRM6A36-2X/32QRV |
|
Order Code (Material No.) |
R983032404 |
|
|
Valve Type |
2-way Pressure-Compensated Flow Control Valve (Sandwich Plate) |
|
|
Performance Parameters |
Nominal Size |
NG6 (D03 / ISO 4401-03-02-0-05) |
|
Max. Operating Pressure (P-port) |
315 bar |
|
|
Max. Drain Pressure (Y-port) |
160 bar (recommend zero backpressure to tank) |
|
|
Adjustable Flow Range |
~3 – 32 L/min (Code /32Q = max. flow 32 L/min — special/extended range for NG6)* |
|
|
Throttle Direction |
A → A₁ (Meter-In); Free return A₁ → A via integrated check ("A" version) |
|
|
Compensation |
Integrated pressure compensator (keeps ∆P across orifice constant, typ. 3–5 bar) |
|
|
Mechanical Interface |
Mounting Style |
Sandwich Plate (installed between NG6 directional valve and subplate) |
|
Mounting Bolts |
4 × M5 (ISO 4762, Grade 10.9), torque ~8–10 Nm cross pattern |
|
|
Adjustment Type |
Spindle with Scale & Lock Nut ("36" code) + Protective Cap |
|
|
Drain Requirement |
External drain port Y → Tank (dedicated line, zero backpressure) |
|
|
Weight |
Approx. 1.4 kg |
|
|
Media & Environment |
Seal Material |
FKM (Viton®) — suffix V |
|
Compatible Fluids |
Mineral Oils (HL/HLP), HFC (Water Glycol), HFD (Phosphate Ester — with FKM) |
|
|
Operating Temp. Range |
-20°C to +80°C (with FKM seals) |
|
|
Fluid Cleanliness |
ISO 4406 17/15/12 or cleaner |
|
|
Special Note |
IN001 = Internal Inspection Lot Reference (no functional difference) |
![]()
| R900960911 4WREE10WB50-2X/G24K31/F1V |
| R900960910 4WREE10WB50-2X/G24K31/F1V |
| R901268120 4WREE10WB75-2X/G24K31/A1V |
| R901244712 4WREE10XA00-2X/G24K31/A1V-953 |
| R900938420 4WREE6E04-2X/G24K31/A1V |
| R900978168 4WREE6E04-2X/G24K31/F1V |
| R900912156 4WREE6E08-2X/G24K31/A1V |
| R900974228 4WREE6E08-2X/G24K31/A1V-280 |
| R901354730 4WREE6E08-2X/G24K31/F1M |
| R900928726 4WREE6E08-2X/G24K31/F1V |
| R901394155 4WREE6E1-08-2X/G24K31/A1M |
| R900933794 4WREE6E1-08-2X/G24K31/A1V |
| R901354733 4WREE6E1-08-2X/G24K31/F1M |
| R900976811 4WREE6E1-08-2X/G24K31/F1V |
| R901394310 4WREE6E1-16-2X/G24K31/A1M |
| R900915686 4WREE6E1-16-2X/G24K31/A1V |
| R901155084 4WREE6E1-16-2X/G24K31/A1V-280 |
| R900617482 4WREE6E1-16-2X/G24K31/F1V |
| R901368370 4WREE6E1-32-2X/G24K31/A1M |
| R900928553 4WREE6E1-32-2X/G24K31/A1V |
| R901154930 4WREE6E1-32-2X/G24K31/A1V-280 |
| R901354735 4WREE6E1-32-2X/G24K31/F1M |
| R900949222 4WREE6E1-32-2X/G24K31/F1V |
| R901371016 4WREE6E16-2X/G24K31/A1M |
| R900920567 4WREE6E16-2X/G24K31/A1V |
| R900974920 4WREE6E16-2X/G24K31/A1V-280 |
| R900774364 4WREE6E16-2X/G24K31/A1V=LB |
| R900941623 4WREE6E16-2X/G24K31/F1V |
| R901312781 4WREE6E3-16-2X/G24K31/A1V |
| R900706670 4WREE6E3-32-2X/G24K31/A1V |
| R900957273 4WREE6E3-32-2X/G24K31/F1V |
| R900907114 4WREE6E32-2X/G24K31/A1V |
| R901220128 4WREE6E32-2X/G24K31/A1V-204=XV |
| R900974914 4WREE6E32-2X/G24K31/A1V-280 |
| R900975521 4WREE6E32-2X/G24K31/A1V=LB |
Q1: What is the difference between "A" and "B" versions of 2FRM6?
A:
2FRM6A… = Throttling in A → A₁ direction (meter-in on Port A side). Stacked between directional valve and subplate on the A-port.
2FRM6B… = Throttling in B → B₁ direction (meter-in on Port B side).
For independent speed control on both extend and retract, one A-version and one B-version are typically stacked. The reverse flow always passes through a free-flow check valve with no restriction.
Q2: Why is an external drain (Y port) required and what happens if I don't connect it?
A: The pressure compensator spool needs a tank-pressure reference. The Y port must be plumbed directly to the reservoir with zero backpressure. If Y is blocked or sees backpressure, the compensator cannot regulate → flow becomes pressure-sensitive and unstable. Never omit or plug the Y port on a 2FRM valve.
Q3: How is this different from a Z2FS6 needle throttle valve?
A: The 2FRM6 has a pressure compensator maintaining constant ∆P across the metering orifice, so set flow stays constant despite load pressure changes on P or A ports. A Z2FS6 is a simple needle throttle — flow varies with ∆P. Use 2FRM when consistent actuator speed under varying load is critical; use Z2FS for basic, cost-sensitive throttling.
Q4: What does the "32Q" flow code mean in practice?
A: /32Q sets the maximum adjustable flow to approx. 32 L/min — this is an extended-range orifice for NG6 size. The valve will regulate flow up to this value, but pressure drop will be considerable near max flow. For better efficiency at sustained high flows (>20 L/min), an NG10 (2FRM10) valve is recommended. For finer low-flow adjustment resolution, choose a smaller Q-code (/6Q, /10Q, /16Q).
Q5: Why FKM (Viton) seals — is NBR not enough?
A: The V suffix = FKM seals, required for:
Temperatures above +70°C (up to +80°C)
Water glycol (HFC) or phosphate ester (HFD) fire-resistant fluids
For standard mineral oil (HL/HLP) at normal temps, NBR is acceptable. The FKM version (this part R983032404) offers broader fluid compatibility and higher temp rating — select based on your actual hydraulic fluid.