Product Details:
|
| Porting Pattern: | ISO 4401-03-02-0-05 / DIN 24340 Form A | Mounting Bolts: | 4 × M5 (ISO 4762, Grade 10.9) |
|---|---|---|---|
| Adjustment Type: | Knob / Hex Spindle With Scale + Lock Nut ("36" Code = With Lock Nut & Scale) | Weight: | Approx. 1.4 Kg |
| Operating Temp. Range: | -20°C To +80°C (with FKM Seals) | ||
| Highlight: | Rexroth speed control valve,Rexroth hydraulic control valve,Germany-made Rexroth valve |
||
|
Parameter Category |
Parameter |
Specification |
|---|---|---|
|
General Information |
Brand / Model |
Rexroth (Germany), 2FRM6A36-2X/1.5QRV |
|
Order Code (Material No.) |
R983032394 |
|
|
Valve Type |
2-way Pressure-Compensated Flow Control Valve (Sandwich Plate) |
|
|
Performance Parameters |
Nominal Size |
NG6 (D03 / ISO 4401-03) |
|
Max. Operating Pressure |
315 bar (P-port), 160 bar (T-port / drain) |
|
|
Adjustable Flow Range |
0.03 – 1.5 L/min (1.5QR = max. flow 1.5 L/min) |
|
|
Flow Characteristic |
Temperature & Pressure Compensated (via integrated pressure compensator) |
|
|
Throttle Direction |
A → A₁ (meter-in); free return via integrated check (A₁ → A) — "A" version |
|
|
Mechanical Interface |
Mounting Style |
Sandwich Plate (between directional valve and subplate) |
|
Porting Pattern |
ISO 4401-03-02-0-05 / DIN 24340 Form A |
|
|
Mounting Bolts |
4 × M5 (ISO 4762, Grade 10.9) |
|
|
Adjustment Type |
Knob / Hex Spindle with Scale + Lock Nut ("36" code = with lock nut & scale) |
|
|
Drain Requirement |
External drain (Y port) to tank, zero backpressure |
|
|
Weight |
Approx. 1.4 kg |
|
|
Media & Environment |
Seal Material |
FKM (Viton®) — suffix V |
|
Compatible Fluids |
Mineral Oils (HL/HLP), HFC (Water Glycol), HFD (Phosphate Ester — with FKM) |
|
|
Operating Temp. Range |
-20°C to +80°C (with FKM seals) |
|
|
Fluid Cleanliness |
ISO 4406 17/15/12 or cleaner (tighter than standard due to small orifice) |
|
|
Special Note |
IN001 = Internal Note / Inspection Lot — typically a QC/batch traceability tag, no functional impact |
![]()
| R983032405 2FRM6B36-2X/0.2QRV-IN001 |
| R983032406 2FRM6B36-2X/0.6QMV-IN001 |
| R983032407 2FRM6B36-2X/0.6QRV-IN001 |
| R983032408 2FRM6B36-2X/1.5QMV-IN001 |
| R983032409 2FRM6B36-2X/1.5QRV-IN001 |
| R983032421 2FRM6B36-2X/3QMV-IN001 |
| R983032410 2FRM6B36-2X/3QRV-IN001 |
| R983032411 2FRM6B36-2X/6QMV-IN001 |
| R983032412 2FRM6B36-2X/6QRV-IN001 |
| R983032413 2FRM6B36-2X/10QMV-IN001 |
| R983032414 2FRM6B36-2X/10QRV-IN001 |
| R983032415 2FRM6B36-2X/16QMV-IN001 |
| R983032416 2FRM6B36-2X/16QRV-IN001 |
| R983032417 2FRM6B36-2X/25QMV-IN001 |
| R983032418 2FRM6B36-2X/25QRV-IN001 |
| R983032419 2FRM6B36-2X/32QMV-IN001 |
| R983032420 2FRM6B36-2X/32QRV-IN001 |
Q1: What is the difference between "A" and "B" versions of 2FRM6?
A:
2FRM6A… = Throttling in A → A₁ direction (meter-in control when valve is between directional valve and subplate on Port A). Free return A₁ → A via check valve.
2FRM6B… = Throttling in B → B₁ direction (meter-in on Port B).
Choose based on which actuator line you want to control. For bidirectional speed control, two valves (one A + one B) are typically stacked.
Q2: Why does this valve need an external drain (Y port)?
A: The integrated pressure compensator (which keeps ∆P across the orifice constant) requires a zero-backpressure drain to tank (Y port) to sense and balance correctly. If the Y line is blocked or sees backpressure, the compensator will malfunction and flow will become unstable. Run Y directly to the tank reservoir.
Q3: How accurate is the flow vs. a simple needle throttle (Z2FS6)?
A: Unlike the Z2FS needle valve (which is notpressure-compensated), the 2FRM6 has a pressure compensator that maintains a constant pressure drop across the orifice. This means the set flow stays nearly constant despite load-induced pressure fluctuations on P or A — ideal for consistent cylinder speed control. Accuracy is typically ±3–5% of set flow within rated ∆P.
Q4: The valve is set for 0.03–1.5 L/min — can it be used for higher flows?
A: No. The "1.5Q" code fixes the maximum flow at 1.5 L/min. For higher flows (e.g. 6 L/min, 16 L/min), select a 2FRM6 with a different Q-code (e.g. /6Q, /16Q). Oversizing the flow range reduces fine-adjustment resolution — match the Q-range to your application.
Q5: Why FKM (Viton) seals and what if I use mineral oil only?
A: The V suffix = FKM seals, required for:
Higher temperature service (up to +80°C)
Water glycol (HFC) or phosphate ester (HFD) fluids
For mineral oil only at ≤70°C, an NBR-sealed version is acceptable and slightly lower cost. The FKM version (this part R983032394) gives broader fluid compatibility and higher temp rating.
Contact Person: Mr. liyun
Tel: +8615280488899