Product Details:
|
| Order Code: | R902453681 | Full Model: | AA10VS010DR/52R-VPA14N00 |
|---|---|---|---|
| Pump Type: | Axial Piston Variable Pump (Swashplate Design, Open Circuit) | Displacement: | 10 Cm³/rev (approx. 10.5 Cm³/rev Geometric) |
| Control Type: | DR (Direct-Acting Pressure Control / Pressure Compensator) |
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth A10VSO Series 52 |
|
Order Code |
R902453681 |
|
Full Model |
AA10VSO10DR/52R-VPA14N00 |
|
Pump Type |
Axial Piston Variable Pump (Swashplate Design, Open Circuit) |
|
Displacement |
10 cm³/rev (approx. 10.5 cm³/rev geometric) |
|
Control Type |
DR (Direct-Acting Pressure Control / Pressure Compensator) |
|
Nominal Pressure |
250 bar |
|
Peak Pressure |
315 bar |
|
Nominal Size |
NG10 |
|
Rotation Direction |
Right-hand (R, viewed from shaft end) |
|
Shaft Type |
Parallel Keyed Shaft (DIN 6885) |
|
Ports |
S (Suction), B (Pressure), L (Case Drain), X (Control) |
|
Port Size |
Code 14 (Metric threads) |
|
Mounting Flange |
ISO 3019-2 (SAE 2-bolt) |
|
Max. Speed |
Approx. 3000 - 3600 rpm (dependent on inlet conditions) |
|
Seal Material |
FKM (Viton) |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HETG, HEES, HFDU |
|
Operating Temperature |
-20°C to +80°C |
|
Weight |
Approx. 9 kg |
|
Country of Origin |
Germany |
Q1: What is the main function of the "DR" control?
A: The DR control is a pressure compensator. It automatically adjusts the pump's swashplate angle (displacement) to maintain a constant preset system pressure. When system pressure reaches the DR setting, the pump de-strokes to near-zero flow, reducing energy consumption and heat generation. It is ideal for systems with long holding periods.
Q2: What does the "VPA14N00" suffix indicate?
A: This code defines the mechanical configuration:
V: FKM (Viton) seals, suitable for a wider range of fluids and higher temperatures than standard NBR.
P: Standard parallel key shaft (DIN 6885).
A14: Port size code 14 (metric threads) on the A side (rear).
N00: No through-drive capability (solid shaft end).
Q3: Can this pump be used as a motor?
A: No. The A10VSO series with DR control is designed specifically for open-circuit pump applications. It is not recommended for use as a hydraulic motor.
Q4: What is the purpose of the X port?
A: The X port is the external pilot port for the DR pressure control valve. It can be used to:
Remotely set pressure: Connect an external relief valve to control the pump's pressure setting remotely.
Unload the pump: By depressurizing the X port, the pump can be forced to zero pressure for unloading.
Q5: What are the key differences between A10VSO and A2FO series?
A:
|
Feature |
A10VSO (This Pump) |
A2FO (Previous Query) |
|---|---|---|
|
Design |
Swashplate, Variable Displacement |
Bent-Axis, Fixed Displacement |
|
Control |
Variable (DR pressure control) |
Fixed (Flow varies only with speed) |
|
Application |
Open circuit, pressure-controlled systems |
Open circuit, constant flow systems |
|
Efficiency |
High at partial flow (due to destroke) |
High at constant flow |
Contact Person: Mr. liyun