Product Details:
|
| Weight: | Approx. 1.8 - 2.1 Kg | Supply Voltage: | 24 V DC (via External Amplifier) |
|---|---|---|---|
| Max. Operating Pressure: | 210 Bar (Ports A, B) | Rated Flow (Qn): | 25 L/min |
| Primary Function: | Electronically Controlled, Pressure-compensated Flow Regulation For Precise Actuator Speed Control Independent Of Load Changes. | ||
| Highlight: | Rexroth hydraulic speed control valve,German Rexroth hydraulic valve,Rexroth 2FRE6B-2X valve |
||
|
Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth 2FRE 6 Series |
|
Order Code |
R900937870 |
|
Full Model |
2FRE 6 B-2X/25QK4MV |
|
Valve Type |
2-Way Proportional Flow Control Valve with Pressure Compensation |
|
Primary Function |
Electronically controlled, pressure-compensated flow regulation for precise actuator speed control independent of load changes. |
|
Control Type |
Proportional solenoid with inductive position transducer (requires external amplifier). |
|
Nominal Size |
NG6 |
|
Max. Operating Pressure |
210 bar (Ports A, B) |
|
Rated Flow (Qn) |
25 L/min |
|
Flow Characteristic |
Progressive (Q) |
|
Pressure Compensation |
Yes (Type B compensator) |
|
Check Valve |
No (Flow control direction A→B only, reverse flow blocked) |
|
Ports |
A, B |
|
Mounting |
Subplate Mounting (ISO 4401-03-02-0-05) |
|
Electrical Connection |
K4 (Individual 3-pin connector: 2 pins + PE) |
|
Seal Material |
FKM (Fluorocarbon Rubber) |
|
Supply Voltage |
24 V DC (via external amplifier) |
|
Hydraulic Fluid |
Mineral oils (HL, HLP), HETG, HEES, HFDU, HFDR |
|
Weight |
Approx. 1.8 - 2.1 kg |
|
Origin |
Germany |
Q1: What is the key advantage of the 2FRE valve over a standard throttle valve?
A: The 2FRE features built-in pressure compensation. This means it maintains a constant flow rate even if the system pressure (load) changes, ensuring consistent actuator speed. A standard throttle valve's flow would vary with pressure.
Q2: What does the "25Q" in the model number indicate?
A: 25 is the rated flow capacity (25 L/min). Q denotes a progressive flow characteristic, providing finer resolution and easier control at lower flow rates.
Q3: Does this valve allow free flow in the reverse direction?
A: No. The suffix "M" indicates there is no integrated check valve. Flow is controlled from A→B, and flow from B→A is blocked. If bidirectional flow is needed, a different variant (e.g., with suffix "V") must be selected.
Q4: What external equipment is needed to operate this valve?
A: This valve requires an external proportional amplifier (e.g., Rexroth VT-VRPA1 series). The amplifier provides the 24V DC power to the solenoid and processes the command signal (e.g., 0-10V) and the valve's position feedback.
Q5: How is the flow direction configured?
A: Flow is controlled in the direction from port A to port B (A→B). The valve's subplate or label will have a marked arrow indicating this direction. It cannot be reversed internally.