Product Details:
|
| Function: | 4/3-way (3 Positions, 4 Ports) | Spool Type: | W8 (Overlap Spool) With Electrical Position Feedback |
|---|---|---|---|
| Nominal Size: | NG16 (CETOP 7) | Max. Operating Pressure: | P, A, B: 350 Bar |
| Rated Flow: | 150 L/min (at Δp = 10 Bar Per Control Land) | ||
| Highlight: | Rexroth proportional directional valve,Rexroth hydraulic valve with warranty,German Rexroth 4WRDE16 valve |
||
|
Parameter |
Specification |
|---|---|
|
Order Number |
R901502770 |
|
Model |
4WRDE16W8-150L-6X/MXY/24A5 |
|
Type |
3-stage, pilot-operated high-response proportional directional valve |
|
Function |
4/3-way (3 positions, 4 ports) |
|
Spool Type |
W8 (Overlap spool) with electrical position feedback |
|
Nominal Size |
NG16 (CETOP 7) |
|
Max. Operating Pressure |
P, A, B: 350 bar |
|
Rated Flow |
150 L/min (at Δp = 10 bar per control land) |
|
Max. Flow |
Approx. 460 L/min |
|
Electronics |
Integrated On-Board Electronics (OBE) |
|
Supply Voltage |
24V DC (18...35 VDC, /24) |
|
Control Signal |
±10 V DC (Analog voltage input, /A5) |
|
Feedback Signal |
±10 V DC (Spool position actual value) |
|
Pilot Oil Supply |
External (X) |
|
Pilot Oil Return |
External (Y) |
|
Seal Material |
NBR (M) |
|
Electrical Connector |
7-pin plug (6 + PE, DIN EN 175201-804) |
|
Mounting Interface |
ISO 4401-07-07-0-05 (CETOP 7 subplate) |
|
Suitable Media |
Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR |
|
Media Temperature |
-20°C to +80°C (optimal 40–50°C) |
|
Viscosity Range |
20 to 380 mm²/s |
|
Weight |
Approx. 10.5 kg |
![]()
| 4WRZE25W6-220-72/6EG24N9K31/F1D3M |
| 4WRZE25W6-220-72/6EG24N9K31/F1D3V |
| 4WRZE25W6-220-72/6EG24N9K31/F1V |
| 4WRZE25W6-325-72/6EG24EK31/F1D3M |
| 4WRZE25W6-325-72/6EG24ETK31/A1D3M |
| 4WRZE25W6-325-72/6EG24ETK31/F1D3V |
| 4WRZE25W6-325-72/6EG24ETK31/F1M |
| 4WRZE25W6-325-72/6EG24K31/A1D3M |
| 4WRZE25W6-325-72/6EG24K31/A1M |
| 4WRZE25W6-325-72/6EG24K31/F1D3M |
| 4WRZE25W6-325-72/6EG24N9EK31/A1D3M |
| 4WRZE25W6-325-72/6EG24N9EK31/A1M |
| 4WRZE25W6-325-72/6EG24N9EK31/A1V |
| 4WRZE25W6-325-72/6EG24N9EK31/F1D3M |
| 4WRZE25W6-325-72/6EG24N9EK31/F1M |
| 4WRZE25W6-325-72/6EG24N9ETK31/A1D3M |
| 4WRZE25W6-325-72/6EG24N9ETK31/A1M |
| 4WRZE25W6-325-72/6EG24N9ETK31/F1D3M |
| 4WRZE25W6-325-72/6EG24N9K31/A1M |
| 4WRZE25W6-325-72/6EG24N9K31/A1V |
| 4WRZE25W6-325-72/6EG24N9K31/F1D3M |
| 4WRZE25W6-325-72/6EG24N9K31/F1D3V |
| 4WRZE25W6-325-72/6EG24N9K31/F1M |
| 4WRZE25W6-325-72/6EG24N9K31/F1V |
| 4WRZE25W6-325-72/6EG24N9TK31/A1D3M |
| 4WRZE25W6-325-72/6EG24N9TK31/F1D3V |
| 4WRZE25W8-220-72/6EG24EK31/A1D3M |
| 4WRZE25W8-220-72/6EG24EK31/F1D3M |
| 4WRZE25W8-220-72/6EG24ETK31/A1D3M |
| 4WRZE25W8-220-72/6EG24K31/A1D3M |
| 4WRZE25W8-220-72/6EG24K31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9EK31/A1D3M |
| 4WRZE25W8-220-72/6EG24N9EK31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9ETK31/F1D3M |
| 4WRZE25W8-220-72/6EG24N9ETK31/F1D3V |
| 4WRZE25W8-220-72/6EG24N9K31/A1D3V |
| 4WRZE25W8-220-72/6EG24N9K31/A1M |
| 4WRZE25W8-220-72/6EG24N9K31/F1D3M |
| 4WRZE25W8-325-72/6EG24EK31/A1D3M |
| 4WRZE25W8-325-72/6EG24EK31/F1D3M |
| 4WRZE25W8-325-72/6EG24ETK31/A1D3M |
| 4WRZE25W8-325-72/6EG24ETK31/F1M |
| 4WRZE25W8-325-72/6EG24K31/A1D3M |
| 4WRZE25W8-325-72/6EG24K31/A1M |
| 4WRZE25W8-325-72/6EG24N9EK31/A1D3M |
| 4WRZE25W8-325-72/6EG24N9EK31/A1D3V |
| 4WRZE25W8-325-72/6EG24N9EK31/A1V |
| 4WRZE25W8-325-72/6EG24N9EK31/F1D3M |
| 4WRZE25W8-325-72/6EG24N9EK31/F1D3V |
| 4WRZE25W8-325-72/6EG24N9ETK31/F1D3M |
| 4WRZE25W8-325-72/6EG24N9ETK31/F1D3V |
| 4WRZE25W8-325-72/6EG24N9K31/A1D3M |
| 4WRZE25W8-325-72/6EG24N9K31/A1M |
| 4WRZE25W8-325-72/6EG24N9K31/F1D3M |
FAQ:
3-Stage Design & High Dynamics
Unlike standard 2-stage valves, the 4WRDE series uses a 3-stage amplification (pilot + main spool). The pilot stage is a high-response nozzle-flapper system (4WS2EM6), which provides exceptional dynamic response and is ideal for servo-grade applications.
Control Signal (/A5)
The /A5 suffix indicates a ±10 V DC voltage input for the command signal. This valve also outputs a ±10 V DC actual value signal representing the main spool position, enabling full closed-loop control via an external controller.
Pilot Oil Configuration (/MXY)
This valve requires external pilot oil supply (X port) and external pilot oil return (Y port). You must provide clean, filtered pilot oil to the X port and ensure the Y port drains directly to the tank with minimal backpressure (typically < 10 bar).
Spool Type (W8)
The W8 spool is an overlap spool (positive overlap). This design minimizes internal leakage when the valve is in the center position but requires a higher deadband control signal to initiate movement. It is suitable for applications where holding position and minimal leakage are critical.
Critical Installation Notes
Drain Line: The external pilot drain (Y port) must be connected directly to the tank with a dedicated line. Backpressure on Y must be kept low.
Cleanliness: Maintain high oil cleanliness (recommended NAS 1638 Class 8 or ISO 4406 20/18/15) due to the sensitive nozzle-flapper pilot stage.
Pilot Supply: Provide clean, regulated pilot pressure to the X port (typically 25–315 bar).
Contact Person: Mr. liyun
Tel: +8615280488899