logo
Home ProductsRexroth Hydraulic Pump

PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

I'm Online Chat Now

PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16	
PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump
PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16	
PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16	
PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

Large Image :  PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

Description
What Is The Weight Range Of The Pilot-operated PV7 Series?: 10–35 Kg (depends On Displacement And Control Type) What Is The Control Type Of The PV7-A Series?: Direct-acting Pressure Compensation
Model Range: PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 Maximum Operating Pressure: 210 Bar (continuous), 250 Bar (peak)
Viscosity Range: 10–1000 Mm²/s (operation); 2–1500 Mm²/s (start-up)
Highlight:

Rexroth PV7 vane pump

,

German imported hydraulic pump

,

original Rexroth spot pump

PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16    
PV7-1X/10-14RE01MW0-16 PV7 series original Rexroth German imported spot hydraulic vane pump

Parameter Specification
Model Series PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typical models)
Displacement per Revolution 10–25 cm³/rev (varies by specific model)
Maximum Operating Pressure 210 bar (continuous), 250 bar (peak)
Maximum Speed 1800–3600 rpm (depends on displacement and fluid viscosity)
Minimum Speed 600 rpm (ensures stable operation)
Fluid Medium Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended)
Fluid Temperature Range -20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range 10–1000 mm²/s (operation); 2–1500 mm²/s (start-up)
Volumetric Efficiency ≥90% (at rated pressure and speed)
Total Efficiency ≥80% (at rated working condition)
Noise Level ≤65 dB(A) (at 1 m distance under rated operation)
Suction Pressure -0.8 bar to +1 bar (absolute pressure: 0.2–1.1 bar)
Mounting Type Flange mounting (ISO 3019-2 standard), foot mounting (optional)
Shaft Connection Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Seal Type Viton® or NBR shaft seals (resistant to high temperature and oil)
Inlet/Outlet Port BSPP, BSPT or SAE thread (port size matches displacement)
Weight 8–15 kg (varies by model and configuration)

PV7-1X/6</p>
<table style= PV7-1X/40-45RE37MC0-16-P90 PV7-1X/25-30RE01MC0-16-P100Q38 PV7-1X/100-150RE07MC0-08-A464 PV7-1X/100-118RE07MD0-16 PV7-1X/10-14RE01MN0-16 PV7-1X/40-45RE37MC5-16 PV7-1X/100-118RE07MC5-16 PV7-1X/25-30RE01KC3-16 PV7-1X/10-20RE01MC5-10WG PV7-1X/25-30RE01MW0-16 PV7-1X/16-20RE01MD3-16 PV7-1X/16-20RE01MC0-16-P110 PV7-1X/40-45RE37KD0-16-C3.1 PV7-1X/63-71RE07MC5-16WH PV7-1X/16-30RE01KC0-08 PV7-1X/10-14RE01MD5-16 PV7-1X/63-71RE07MC6-16 PV7-1X/16-20RE01KD0-16 PV7-1X/10-14RE01MW0-16 PV7-1X/63-71RE07MC0-16-C3.1 PV7-1X/16-30RE01MW0-08WH PV7-1X/100-150RE07MC0-08-A446 PV7-1X/25-30RE01MC5-16WG PV7-1X/10-20RE01MC0-10-A497 PV7-1X/100-150RE07KC0-08 PV7-1X/100-150RE07MD5-08 PV7-1X/25-45RE01MC0-08-P25Q50 PV7-1X/40-71RE37MC5-08 PV7-1X/10-14RE01KD0-16 PV7-1X/16-20RE01MC0-16-P120 PV7-1X/100-150RE07MW0-08WH PV7-1X/16-20RE01MC5-16WG PV7-1X/10-20RE01MW0-10WH PV7-1X/63-94RE07KD0-08 PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 PV7-1X/63-94RE07MC0-08-P80Q114 PV7-1X/40-45RE37MC5-16WH PV7-1X/10-14RE01KN0-16 PV7-1X/25-30RE01MC5-16WH PV7-1X/63-71RE07KC0-16 PV7-1X/10-20RE01MC3-10 PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 PV7-1X/63-71RE07KD0-16 PV7-1X/16-20RE01MC8-16 PV7-1X/40-71RE37MW0-08WH PV7-1X/40-45RE37MD0-16-P50Q36 PV7-1X/40-45RE37MC7-16WG PV7-1X/100-118RE07MN5-16 PV7-1X/25-45RE01MC7-08WG PV7-1X/63-71RE07MC7-16 PV7-1X/100-150RE07MC3-08 PV7-1X/40-45RE37KC0-16 PV7-1X/63-94RE07MC5-08 PV7-1X/16-20RE01MC0-16-P60Q26 PV7-1X/16-20RE01MC5-16 PV7-1X/40-71RE37MC5-08WG PV7-1X/25-45RE01MC7-08 PV7-1X/25-30RE01MW5-16WH PV7-1X/10-20RE01MD0-10 PV7-1X/63-71RE07MD0-16-Q90 PV7-1X/16-30RE01MC3-08 PV7-1X/100-150RE07MC7-08 PV7-1X/100-118RE07MN0-16 PV7-1X/10-20RE01MC5-10 PV7-1X/25-30RE01MC5-16WH-A234 PV7-1X/100-150RE07MC5-08WH PV7-1X/25-30RE01MW0-16WH PV7-1X/10-20RE01MC7-10WH PV7-1X/25-45RE01MC5-08 PV7-1X/40-45RE37MC8-16 PV7-1X/16-20RE01MW0-16WH PV7-1X/16-20RE01MC3-16-P50Q25 PV7-1X/100-118RE07KC0-16 PV7-1X/40-71RE37MC5-08WH PV7-1X/100-118RE07MC6-16 PV7-1X/40-71RE37MC3-08 PV7-1X/40-71RE37MC7-08WH PV7-1X/10-14RE01MW0-16WH PV7-1X/10-20RE01MC3-10-A497 PV7-1X/16-20RE01MC3-16 PV7-1X/16-20RE01MC5-16WH PV7-1X/63-71RE07MC3-06-A460 PV7-1X/16-30RE01MC5-08WH PV7-1X/10-14RE01MC0-16-P100 PV7-1X/63-94RE07MC5-08WH PV7-1X/10-14RE01MC3-16 PV7-1X/40-45RE37MD0-16 PV7-1X/100-118RE07MC7-16WH PV7-1X/25-45RE01MC5-08WH PV7-1X/16-20RE01MC0-16 PV7-1X/63-71RE07MC5-16WG PV7-1X/63-71RE07KC3-16 PV7-1X/10-20RE01MC5-10WH PV7-1X/16-20RE01MC7-16 PV7-1X/10-14RE01MC7-16 PV7-1X/63-94RE07MC0-08 PV7-1X/16-20RE01MC0-16-P100Q29 PV7-1X/25-30RE01MC0-16-P100Q36 PV7-1X/40-45RE37MW5-16WH PV7-1X/10-14RE01MC0-16-P45 PV7-1X/25-45RE01MN0-08 PV7-1X/25-30RE01MC0-16 PV7-1X/63-94RE07MC0-08-P75 PV7-1X/63-71RE07MW5-16WH PV7-1X/25-30RE01MC5-16 PV7-1X/40-71RE37MD0-08 PV7-1X/100-150RE07MD0-08 PV7-1X/10-20RE01MC7-10 PV7-1X/10-14RE01MD3-16 PV7-1X/100-118RE07MW0-16WH PV7-1X/100-118RE07KD0-16 PV7-1X/10-14RE01MC5-16 PV7-1X/63-94RE07MN0-08 PV7-1X/10-14RE01KC0-16 PV7-1X/40-45RE37MC3-16 PV7-1X/40-45RE37MC7-16 PV7-1X/16-20RE01MC0-16-C3.1 PV7-1X/40-45RE37MC0-16-A446 PV7-1X/100-118RE07MW0-16WG PV7-1X/100-150RE07MC0-08 PV7-1X/63-94RE07MC5-08WG PV7-1X/16-20RE01KC0-16 PV7-1X/40-55RE37MC0-08-A449 PV7-1X/63-94RE07MD0-08 PV7-1X/16-20RE01MD0-16-Q25 PV7-1X/40-45RE37MD0-16-P50Q39 PV7-1X/63-71RE07MD0-16-Q65 PV7-1X/16-30RE01MC0-08 PV7-1X/40-45RE37MW0-16 PV7-1X/40-71RE37MC0-08 PV7-1X/100-118RE07MW6-16WH PV7-1X/16-30RE01MC5-08WG PV7-1X/10-20RE01MC0-10 PV7-1X/63-71RE07MW0-16 PV7-1X/63-94RE07KC0-08 PV7-1X/40-45RE37MC7-16WH PV7-1X/10-14RE01MC0-16-P60Q15 PV7-1X/63-71RE07KW0-16WG PV7-1X/100-118RE07KC5-16 PV7-1X/25-30RE01MC7-16 PV7-1X/63-71RE07MC5-16 PV7-1X/25-30RE01KD0-16 PV7-1X/10-14RE01MC5-16WH PV7-1X/10-20RE01MC0-10-P45 PV7-1X/16-20RE01MW0-16 PV7-1X/16-30RE01MD0-08 PV7-1X/25-45RE01MD0-08

FAQ:

1. Q: What types of hydraulic oil are compatible with PV7 series pumps?
A: It is compatible with mineral-based hydraulic oils, synthetic hydraulic oils, and biodegradable hydraulic oils that meet the requirements of ISO 6743-4 (category HM, HV, HG). The recommended viscosity range is 10–40 mm²/s at operating temperature.

2. Q: How to select the appropriate displacement model of PV7 series pumps?
A: Select according to the system’s required flow rate and working pressure. The displacement range of PV7 series is 4–180 cm³/rev; calculate the flow rate via the formula: Flow (L/min) = Displacement (cm³/rev) × Speed (rpm) ÷ 1000, and match it with the system’s actual flow demand.

3. Q: Can the PV7 series pumps be operated in both clockwise and counterclockwise directions?
A: Most standard PV7 models are designed for fixed rotational direction, but customized models with reversible rotation are available upon request; confirm the rotation direction requirements with the supplier before purchase.

4. Q: What is the recommended oil temperature range for PV7 series pumps during operation?
A: The optimal operating oil temperature is 40–60 °C; the allowable short-term maximum temperature should not exceed 80 °C, and the minimum temperature should not be lower than 10 °C to avoid viscosity abnormalities affecting performance.

5. Q: What causes abnormal noise during the operation of PV7 series pumps?
A: Common causes include insufficient oil suction (such as clogged suction filters, too-small suction pipe diameters), air mixed in the hydraulic oil, excessive oil viscosity, worn pump internal components, or loose mounting bolts.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)