PV7 Series Hydraulic Oil Pumps
PV7-1X/06-14RE01MA3-07, PV7-1X/06-14RA01MA0-04, PV7-1X/06-14RG01MA0-07 - High-performance hydraulic oil pumps from the PV7 series, imported blade pumps manufactured by Rexroth, Germany.
Technical Specifications
| Parameter |
Specification |
| Model Series |
PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typical models) |
| Displacement per Revolution |
10-25 cm³/rev (varies by specific model) |
| Maximum Operating Pressure |
210 bar (continuous), 250 bar (peak) |
| Maximum Speed |
1800-3600 rpm (depends on displacement and fluid viscosity) |
| Minimum Speed |
600 rpm (ensures stable operation) |
| Fluid Medium |
Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended) |
| Fluid Temperature Range |
-20 °C to +80 °C (operation); -40 °C to +90 °C (storage) |
| Viscosity Range |
10-1000 mm²/s (operation); 2-1500 mm²/s (start-up) |
![PV7-1X/06
<div class=]()
Available Models
PV7-1X/40-45RE37KC0-16, PV7-1X/63-94RE07MC5-08, PV7-1X/16-20RE01MC0-16-P60Q26, PV7-1X/16-20RE01MC5-16, PV7-1X/40-71RE37MC5-08WG, PV7-1X/25-45RE01MC7-08, PV7-1X/25-30RE01MW5-16WH, PV7-1X/10-20RE01MD0-10, PV7-1X/63-71RE07MD0-16-Q90, PV7-1X/16-30RE01MC3-08, PV7-1X/100-150RE07MC7-08, PV7-1X/100-118RE07MN0-16, PV7-1X/10-20RE01MC5-10, PV7-1X/25-30RE01MC5-16WH-A234, PV7-1X/100-150RE07MC5-08WH, PV7-1X/25-30RE01MW0-16WH, PV7-1X/10-20RE01MC7-10WH, PV7-1X/25-45RE01MC5-08, PV7-1X/40-45RE37MC8-16, PV7-1X/16-20RE01MW0-16WH, PV7-1X/16-20RE01MC3-16-P50Q25, PV7-1X/100-118RE07KC0-16, PV7-1X/40-71RE37MC5-08WH, PV7-1X/100-118RE07MC6-16, PV7-1X/40-71RE37MC3-08, PV7-1X/40-71RE37MC7-08WH, PV7-1X/10-14RE01MW0-16WH, PV7-1X/10-20RE01MC3-10-A497, PV7-1X/16-20RE01MC3-16, PV7-1X/16-20RE01MC5-16WH, PV7-1X/63-71RE07MC3-06-A460, PV7-1X/16-30RE01MC5-08WH, PV7-1X/10-14RE01MC0-16-P100, PV7-1X/63-94RE07MC5-08WH, PV7-1X/10-14RE01MC3-16, PV7-1X/40-45RE37MD0-16, PV7-1X/100-118RE07MC7-16WH, PV7-1X/25-45RE01MC5-08WH, PV7-1X/16-20RE01MC0-16, PV7-1X/63-71RE07MC5-16WG, PV7-1X/63-71RE07KC3-16, PV7-1X/10-20RE01MC5-10WH, PV7-1X/16-20RE01MC7-16, PV7-1X/10-14RE01MC7-16, PV7-1X/63-94RE07MC0-08, PV7-1X/16-20RE01MC0-16-P100Q29, PV7-1X/25-30RE01MC0-16-P100Q36, PV7-1X/40-45RE37MW5-16WH, PV7-1X/10-14RE01MC0-16-P45, PV7-1X/25-45RE01MN0-08, PV7-1X/25-30RE01MC0-16, PV7-1X/63-94RE07MC0-08-P75, PV7-1X/63-71RE07MW5-16WH, PV7-1X/25-30RE01MC5-16, PV7-1X/40-71RE37MD0-08, PV7-1X/100-150RE07MD0-08, PV7-1X/10-20RE01MC7-10, PV7-1X/10-14RE01MD3-16, PV7-1X/100-118RE07MW0-16WH, PV7-1X/100-118RE07KD0-16, PV7-1X/10-14RE01MC5-16, PV7-1X/63-94RE07MN0-08, PV7-1X/10-14RE01KC0-16, PV7-1X/40-45RE37MC3-16, PV7-1X/40-45RE37MC7-16, PV7-1X/16-20RE01MC0-16-C3.1, PV7-1X/40-45RE37MC0-16-A446, PV7-1X/100-118RE07MW0-16WG, PV7-1X/100-150RE07MC0-08, PV7-1X/63-94RE07MC5-08WG, PV7-1X/16-20RE01KC0-16, PV7-1X/40-55RE37MC0-08-A449, PV7-1X/63-94RE07MD0-08, PV7-1X/16-20RE01MD0-16-Q25, PV7-1X/40-45RE37MD0-16-P50Q39, PV7-1X/63-71RE07MD0-16-Q65, PV7-1X/16-30RE01MC0-08, PV7-1X/40-45RE37MW0-16, PV7-1X/40-71RE37MC0-08, PV7-1X/100-118RE07MW6-16WH, PV7-1X/16-30RE01MC5-08WG, PV7-1X/10-20RE01MC0-10, PV7-1X/63-71RE07MW0-16, PV7-1X/63-94RE07KC0-08, PV7-1X/40-45RE37MC7-16WH, PV7-1X/10-14RE01MC0-16-P60Q15, PV7-1X/63-71RE07KW0-16WG, PV7-1X/100-118RE07KC5-16, PV7-1X/25-30RE01MC7-16, PV7-1X/63-71RE07MC5-16, PV7-1X/25-30RE01KD0-16, PV7-1X/10-14RE01MC5-16WH, PV7-1X/10-20RE01MC0-10-P45, PV7-1X/16-20RE01MW0-16, PV7-1X/16-30RE01MD0-08, PV7-1X/25-45RE01MD0-08, PV7-1X/100-118RE07MC7-16, PV7-1X/10-14RE01MC0-16-P90, PV7-1X/16-20RE01MC7-16WH, PV7-1X/40-45RE37MD0-16-C3.1, PV7-1X/40-45RE37MW0-16WG, PV7-1X/40-45RE37KD0-16, PV7-1X/40-45RE37MC0-16-P80, PV7-1X/16-30RE01MC5-08, PV7-1X/100-150RE07KD0-08, PV7-1X/40-45RE37MW0-16WH, PV7-1X/10-14RE01MD0-16, PV7-1X/100-150RE07MC5-08WG, PV7-1X/16-30RE01MC7-08, PV7-1X/63-71RE07MC0-06-A460, PV7-1X/10-14RE01MC0-16, PV7-1X/16-30RE01MN0-08, PV7-1X/25-45RE01KC0-08, PV7-1X/63-71RE07MD0-16-Q85, PV7-1X/100-150RE07MN0-08, PV7-1X/63-94RE07MC3-08, PV7-1X/16-20RE01MW0-16WG
Frequently Asked Questions
What is the pressure control response time of the PV7 series?
Rise time: 20-40ms; Fall time: 60-85ms (direct-acting models)
What is the normal operating noise level of PV7 pumps?
≤65 dB(A) at 1m distance under rated conditions; ≤75 dB(A) for special models
How to perform a load test on the PV7 pump?
Gradually load to 25%→50%→75%→100% of rated pressure, running stably for 5-10 minutes per stage
Can the PV7 pump operate at peak pressure continuously?
No, peak pressure (e.g., 250 bar) is for short-term overload; long-term operation at rated pressure is recommended
What is the allowable suction pressure range for PV7 pumps?
-0.8 bar to +1 bar (absolute pressure: 0.2-1.1 bar)