logo
Home ProductsRexroth Hydraulic Pump

PV7-1X/06-10RG01MA0-10 PV7-2X/20-25RE01MA3-10 PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump

I'm Online Chat Now

PV7-1X/06-10RG01MA0-10 PV7-2X/20-25RE01MA3-10 PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump

PV7-1X/06-10RG01MA0-10
PV7-2X/20-25RE01MA3-10	
PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump
PV7-1X/06-10RG01MA0-10
PV7-2X/20-25RE01MA3-10	
PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump PV7-1X/06-10RG01MA0-10
PV7-2X/20-25RE01MA3-10	
PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump

Large Image :  PV7-1X/06-10RG01MA0-10 PV7-2X/20-25RE01MA3-10 PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: PV7-1X/06-10RG01MA0-10 PV7-2X/20-25RE01MA3-10 PV7-1X/06-10RG01MA3-10
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

PV7-1X/06-10RG01MA0-10 PV7-2X/20-25RE01MA3-10 PV7-1X/06-10RG01MA3-10 German PV7 series Rexroth hydraulic oil pump in stock hydraulic pump

Description
What Is The Maximum Flow Rate Of The Direct-acting PV7 Series At 1800 Rpm?: 36 L/min (calculated At Rated Displacement) What Is The Maximum Flow Rate Of The Pilot-operated PV7 Series At 1800 Rpm?: 270 L/min (calculated At Rated Displacement)
What Is The Volumetric Efficiency Of The Direct-acting PV7 Series Under Rated Conditions?: ≥90% (at 160 Bar, 1800 Rpm, ISO VG 46 Oil) What Is The Volumetric Efficiency Of The Pilot-operated PV7 Series Under Rated Conditions?: ≥92% (at 160 Bar, 1800 Rpm, ISO VG 46 Oil)
What Is The Total Efficiency Of The Direct-acting PV7 Series Under Nominal Operation?: ≥80% (includes Mechanical & Volumetric Efficiency)
Highlight:

Rexroth PV7 hydraulic oil pump

,

German Rexroth vane pump

,

hydraulic pump with warranty

Rexroth PV7 Series Hydraulic Oil Pump
Available Models
  • PV7-1X/06-10RG01MA0-10
  • PV7-2X/20-25RE01MA3-10
  • PV7-1X/06-10RG01MA3-10
Technical Specifications
Parameter Specification
Model Series PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typical models)
Displacement per Revolution 10-25 cm³/rev (varies by specific model)
Maximum Operating Pressure 210 bar (continuous), 250 bar (peak)
Maximum Speed 1800-3600 rpm (depends on displacement and fluid viscosity)
Minimum Speed 600 rpm (ensures stable operation)
Fluid Medium Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended)
Fluid Temperature Range -20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range 10-1000 mm²/s (operation); 2-1500 mm²/s (start-up)
PV7-1X/0
</section>
<section>
<div class=Additional Model Variants
  • PV7-1X/06-14RA01MA0-07-P65
  • PV7-1X/06-14RA01MA0-07-P70
  • PV7-2X/20-20RA01MA0-10-P65
  • PV7-2X/20-20RA01MA0-05-P25
  • PV7-2X/20-20RA01MA0-05-P50
  • PV7-1X/06-14RA01MA0-10-A473
  • PV7-1X/06-10RA01MA0-10-P100
  • PV7-1X/06-14RA01MA0-10-A492
  • PV7-2X/20-20RA01MA0-10-C3.1
  • PV7-2X/20-20RA01MA0-05-A480
  • PV7-2X/20-20RA01MA0-10-A480
  • PV7-1X/06-10RA01MA0-10-C3.1
  • PV7-2X/20-20RA01MA0-10-P100
  • PV7-2X/20-25RA01MA0-05-P24Q30
  • PV7-1X/06-10RA01MA0-05-P35Q11
  • PV7-2X/20-25RA01MA0-05-P30Q25
  • PV7-1X/06-10RA01MA0-05-P40Q11
  • PV7-2X/20-25RA01MA0-05-P30Q36
  • PV7-1X/06-10RA01MA0-05-P50Q15
  • PV7-2X/20-25RA01MA0-05-P45Q35
  • PV7-1X/06-10RA01MA0-10-P55Q12
  • PV7-2X/20-25RA01MA0-05-P45Q36
  • PV7-1X/06-10RA01MA0-10-P65Q12
  • PV7-2X/20-25RA01MA0-10-P63Q35
  • PV7-1X/06-10RA01MA0-10-P70Q12
  • PV7-1X/06-10RA01MA0-05-P15Q08
  • PV7-1X/06-14RA01MA0-07-P70Q18
  • PV7-1X/06-10RA01MA0-05-P25Q09
  • PV7-1X/06-14RA01MA0-04-P30Q19
  • PV7-1X/06-10RA01MA0-05-P25Q11
  • PV7-1X/06-10RA01MA0-10-P100Q10
  • PV7-1X/06-10RA01MA0-05-P35Q09
Extended Model Range
  • PV7-1X/63-71RE07MC3-16
  • PV7-1X/100-118RE07MD3-16
  • PV7-1X/63-71RE07MW0-16WG
  • PV7-1X/10-20RE01MD5-10
  • PV7-1X/25-30RE01MW0-16WG
  • PV7-1X/40-45RE37MW5-16WG
  • PV7-1X/100-118RE07MC5-16WG
  • PV7-1X/63-94RE07MC7-08WG
  • PV7-1X/40-45RE37MW6-16WH
  • PV7-1X/100-118RE07MD6-16
  • PV7-1X/40-45RE37MC5-16WG
  • PV7-1X/100-118RE07MC0-16
  • PV7-1X/63-71RE07MD0-16
  • PV7-1X/40-45RE37MC0-16-P90
  • PV7-1X/25-30RE01MC0-16-P100Q38
  • PV7-1X/100-150RE07MC0-08-A464
  • PV7-1X/100-118RE07MD0-16
  • PV7-1X/10-14RE01MN0-16
  • PV7-1X/40-45RE37MC5-16
  • PV7-1X/100-118RE07MC5-16
  • PV7-1X/25-30RE01KC3-16
  • PV7-1X/10-20RE01MC5-10WG
  • PV7-1X/25-30RE01MW0-16
  • PV7-1X/16-20RE01MD3-16
  • PV7-1X/16-20RE01MC0-16-P110
  • PV7-1X/40-45RE37KD0-16-C3.1
  • PV7-1X/63-71RE07MC5-16WH
  • PV7-1X/16-30RE01KC0-08
  • PV7-1X/10-14RE01MD5-16
  • PV7-1X/63-71RE07MC6-16
  • PV7-1X/16-20RE01KD0-16
  • PV7-1X/10-14RE01MW0-16
  • PV7-1X/63-71RE07MC0-16-C3.1
  • PV7-1X/16-30RE01MW0-08WH
  • PV7-1X/100-150RE07MC0-08-A446
  • PV7-1X/25-30RE01MC5-16WG
  • PV7-1X/10-20RE01MC0-10-A497
  • PV7-1X/100-150RE07KC0-08
  • PV7-1X/100-150RE07MD5-08
  • PV7-1X/25-45RE01MC0-08-P25Q50
  • PV7-1X/40-71RE37MC5-08
  • PV7-1X/10-14RE01KD0-16
  • PV7-1X/16-20RE01MC0-16-P120
  • PV7-1X/100-150RE07MW0-08WH
  • PV7-1X/16-20RE01MC5-16WG
  • PV7-1X/10-20RE01MW0-10WH
  • PV7-1X/63-94RE07KD0-08
  • PV7-1X/63-71RE07MW0-16WH
  • PV7-1X/63-71RE07MC7-16WH
  • PV7-1X/40-45RE37MC0-16
  • PV7-1X/63-94RE07MC0-08-P80Q114
  • PV7-1X/40-45RE37MC5-16WH
  • PV7-1X/10-14RE01KN0-16
  • PV7-1X/25-30RE01MC5-16WH
  • PV7-1X/63-71RE07KC0-16
  • PV7-1X/10-20RE01MC3-10
  • PV7-1X/16-20RE01MN0-16
  • PV7-1X/25-45RE01MW0-08WH
  • PV7-1X/63-71RE07MN0-16
  • PV7-1X/63-71RE07KD0-16
  • PV7-1X/16-20RE01MC8-16
  • PV7-1X/40-71RE37MW0-08WH
Frequently Asked Questions
Should the PV7 pump be pre-filled with oil before commissioning?
Yes, fill the housing through the drain port to prevent dry running and component wear.
How to bleed the PV7 pump system?
Loosen the vent screw, manually rotate the coupling or jog the motor, and stop when bubble-free oil flows out.
What is the recommended no-load running time for PV7 pumps?
5-10 minutes to check vibration, leakage, and temperature rise.
How to adjust the pressure of a direct-acting PV7 pump?
  • Clockwise rotation of the adjusting screw: Increase pressure
  • Counterclockwise rotation: Decrease pressure
How to adjust the flow rate of the PV7 pump?
  • Clockwise rotation of the flow adjusting screw: Decrease flow
  • Counterclockwise rotation: Increase flow

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)