logo
Home ProductsRexroth Hydraulic Pump

Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil

I'm Online Chat Now

Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil

Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil
Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil

Large Image :  Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil

Product Details:
Place of Origin: German
Brand Name: Rexroth
Certification: ISO
Model Number: PGH5-3X/080RR11VU2 PGH4-2X/025RR11WU2 PGH2-1X/008RE47MU2 PGH4-21/020LE11VU2 PGH2-1X/008RF47MK0
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 1
Packaging Details: wooden box
Delivery Time: 2 weeks
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100

Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil

Description
Warranty: One Year Rotation: Clockwise Or Counterclockwise
Fuel: +85267220981 Type: Axial Piston Pump
Certifisaarion: ISO9001 Transport Package: Wooden Box
Weight: 13.8 Kg Max Pressure: 280 Bar
Condition: Internal Meshing Principle After Serive: Online Video
Shaft Type: Splined Shaft
Highlight:

Internal Meshing Principle Gear Pump

,

Splined Shaft Hydraulic Pump

,

Filter Diesel Oil Rexroth Gear Pump

PGH Series Quantitative Gear Pumps
Product Models
  • PGH5-3X/080RR11VU2
  • PGH4-2X/025RR11WU2
  • PGH2-1X/008RE47MU2
  • PGH4-21/020LE11VU2
  • PGH2-1X/008RF47MK0
Product Description

Original quantitative gear pump, Rexroth German made hydraulic pump.

Contact: whatsapp +85267220981 | email yli97584@gmail.com
Brand Name Rexroth
Place of Origin Germany
Warranty 12 Months
Video outgoing-inspection Provided
Machinery Test Report Provided
Application Machinery Repair Shops
Material Iron
Condition Original
Quality 100% Tested Great Performance
Certification ISO
Feature Long Life Low Noise
Function Filter Diesel Oil
Power Hydraulic Power
Payment Term T/T 100%
Original Quantitative Rexroth Gear Pump with Internal Meshing Principle and Splined Shaft for Filter Diesel Oil 0
Available Models
R901062757 PGH5-2X/100RE11VU2-A445
R900951303 PGH3-2X/011RE07VU2
R900951301 PGH2-2X/006RE07VU2
R900932175 PGH5-2X/125RE11VE4
R900932166 PGH4-2X/080RE07VE4
R900932165 PGH4-2X/063RE07VE4
R900932159 PGH4-2X/050RE11VU2
R900932141 PGH4-2X/032RE11VU2
R900932140 PGH4-2X/025RE11VU2
R900932139 PGH4-2X/020RE11VU2
R900245596 PGH4-2X/025RE11VU2-A280B
R900204884 PGH5-2X/200RE07VE4-A388
R900064616 PGH3-1X/010LE07MU2
R900061672 PGH2-1X/006RE07ME4
R900057641 PGH5-2X/250RE07VU2-A388
R900086557 PGH5-2X/200RE07VE4
R900086556 PGH5-2X/160RE07VE4
R900086518 PGH5-2X/125RR11VU2
R900086321 PGH4-2X/040RE11VU2
R900961549 PGH2-2X/006RR07VU2
R900961547 PGH2-2X/006LE07VU2
R900961550 PGH2-2X/006LR07VU2
R900951302 PGH2-2X/008RE07VU2
R900961551 PGH2-2X/008RR07VU2
R900961548 PGH2-2X/008LE07VU2
R900961552 PGH2-2X/008LR07VU2
R900961553 PGH3-2X/011LE07VU2
R900961559 PGH3-2X/011LR07VU2
R900951304 PGH3-2X/013RE07VU2
R900961554 PGH3-2X/013LE07VU2
R900961560 PGH3-2X/013LR07VU2
R900951305 PGH3-2X/016RE07VU2
R900961558 PGH3-2X/016RR07VU2
R900961555 PGH3-2X/016LE07VU2
R900961561 PGH3-2X/016LR07VU2
R900086397 PGH4-2X/020RE11VE4
R900086356 PGH4-2X/020RR11VU2
R900086338 PGH4-2X/020LE11VU2
R900086379 PGH4-2X/020LR11VU2
R900086398 PGH4-2X/025RE11VE4
R900086357 PGH4-2X/025RR11VU2
R900086339 PGH4-2X/025LE11VU2
R900086380 PGH4-2X/025LR11VU2
R900932161 PGH4-2X/032RE11VE4
R900086358 PGH4-2X/032RR11VU2
R900086340 PGH4-2X/032LE11VU2
R900086381 PGH4-2X/032LR11VU2
R900932162 PGH4-2X/040RE11VE4
R900086359 PGH4-2X/040RR11VU2
R900086341 PGH4-2X/040LE11VU2
R900086382 PGH4-2X/040LR11VU2
R900932163 PGH4-2X/050RE11VE4
R900086360 PGH4-2X/050RR11VU2
R900086342 PGH4-2X/050LE11VU2
R900086383 PGH4-2X/050LR11VU2
R900086362 PGH4-2X/063RR07VU2
R900086344 PGH4-2X/063LE07VU2
R900086385 PGH4-2X/063LR07VU2
R900086363 PGH4-2X/080RR07VU2
R900086345 PGH4-2X/080LE07VU2
R900086386 PGH4-2X/080LR07VU2
R900086405 PGH4-2X/100RE07VE4
R900086364 PGH4-2X/100RR07VU2
R900086346 PGH4-2X/100LE07VU2
R900086387 PGH4-2X/100LR07VU2
R900086551 PGH5-2X/063RE11VE4
R900932172 PGH5-2X/063RR11VU2
R900086496 PGH5-2X/063LE11VU2
R900086533 PGH5-2X/063LR11VU2
R900932173 PGH5-2X/080RE11VE4
R900086516 PGH5-2X/080RR11VU2
R900086497 PGH5-2X/080LE11VU2
R900086534 PGH5-2X/080LR11VU2
R900932174 PGH5-2X/100RE11VE4
R900086517 PGH5-2X/100RR11VU2
R900086498 PGH5-2X/100LE11VU2
R900086535 PGH5-2X/100LR11VU2
R900932175 PGH5-2X/125RE11VE4
R900086499 PGH5-2X/125LE11VU2
R900086536 PGH5-2X/125LR11VU2
R900086556 PGH5-2X/160RE07VE4
R900086520 PGH5-2X/160RR07VU2
R900086501 PGH5-2X/160LE07VU2
R900086538 PGH5-2X/160LR07VU2
R900086557 PGH5-2X/200RE07VE4
R900086521 PGH5-2X/200RR07VU2
R900086503 PGH5-2X/200LE07VU2
R900086539 PGH5-2X/200LR07VU2
R900932176 PGH5-2X/250RE07VE4
R900086522 PGH5-2X/250RR07VU2
R900086504 PGH5-2X/250LE07VU2
R900086540 PGH5-2X/250LR07VU2
R901147115 PGH5-3X/063RE11VU2
R901147122 PGH5-3X/063RE11VE4
R901147129 PGH5-3X/063RR11VU2
R901147116 PGH5-3X/080RE11VU2
R901147123 PGH5-3X/080RE11VE4
R901147130 PGH5-3X/080RR11VU2
R901147117 PGH5-3X/100RE11VU2
R901147124 PGH5-3X/100RE11VE4
R901147131 PGH5-3X/100RR11VU2
R901147118 PGH5-3X/125RE11VU2
R901147125 PGH5-3X/125RE11VE4
R901147132 PGH5-3X/125RR11VU2
R901147119 PGH5-3X/160RE11VU2
R901147126 PGH5-3X/160RE11VE4
R901147133 PGH5-3X/160RR11VU2
R901147120 PGH5-3X/200RE07VU2
R901147127 PGH5-3X/200RE07VE4
R901147134 PGH5-3X/200RR07VU2
Frequently Asked Questions
Cavitation

This occurs when the pump is starved of fluid, often due to a clogged inlet filter, restricted suction line, or low fluid level, leading to noise and damage.

Q5: How can I troubleshoot low or no flow from my PGH pump?
  • Check that the reservoir fluid level is adequate.
  • Inspect the suction line and inlet filter for blockages or clogs and clean them if necessary.
  • Ensure the fluid viscosity is within the recommended range for the operating temperature.
  • Check for air leaks in the suction line and ensure all connections are tight.
  • Verify that the pump's rotation direction is correct.
  • Inspect internal components (gears, shaft seal) for excessive wear.
Q6: How can I resolve issues with low system pressure or pressure fluctuations?
  • Internal Leakage: Check for worn gears, pump housing, or side plates, which can cause internal leaks and pressure loss. Replacing worn parts is often necessary.
  • System Relief Valve: A malfunctioning or incorrectly set relief valve can cause low pressure. Verify its setting and functionality.
  • Fluid Contamination: Contaminated fluid can damage precision surfaces and cause erratic pressure. Check filters and change the fluid if needed.

Contact Details
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Contact Person: Mr. liyun

Tel: +8615280488899

Send your inquiry directly to us (0 / 3000)