|
Подробная информация о продукте:
|
| WhatsApp: | +85267220981 | Торговая марка: | Мак |
|---|---|---|---|
| Размер порта: | 1 дюйм | Структура: | Поршневой насос |
| Давление: | Высокое давление | Максимум СКОРОСТЬ: | 2800 об / мин |
| Режим привода: | Механически управляемый насос | Положение насоса: | горизонтальный |
| Зарядка: | Micro5p | После снятия: | онлайн -видео |
| Ротация: | 0,2-CP можно транспортировать в обратном направлении | Скорость: | Гидравлическое масло, водный этиленгликол |
| Выделить: | 1 inch Port Size Moog Servo Valve,0.2-cp Reverse Rotation Electrohydraulic Servo Valve,Advanced Alloy Steel/Cast Iron Material Proportional Flow Control Valve |
||
| Parameter | Value |
|---|---|
| Rated Current | 1A |
| Voltage | 24V/220V |
| Power | 0.1 kW |
| Brand | MOOG |
| Place of Origin | Germany |
| Application | LED touch control |
| Material | PVC, Steel, Copper |
| Rated Frequency | 50 Hz |
| Type | Servo proportional valve |
| Control | Electro hydraulic/Proportional |
An electrohydraulic servo valve is a precision component that acts as an interface between the electrical control system and the hydraulic power system. It receives a low-power electrical analog signal and converts it into a proportional, high-power hydraulic output (flow and pressure). This makes it a crucial control core in electrohydraulic servo systems, responsible for both electrical-to-hydraulic signal conversion and power amplification.
A Moog servo valve typically consists of a polarized electrical torque motor and a two-stage hydraulic amplifier.
Proper installation is critical for performance and longevity.
Common faults can be categorized as follows:
Here is a brief troubleshooting chart based on symptoms:
| Potential Trouble | Probable Cause |
|---|---|
| Servovalve does not follow input command | 1. Open coil or coil leads. 2. Clogged inlet filter. |
| Poor response | 1. Clogged inlet orifices or nozzles. 2. Partially clogged filter. 3. "Sticky" spool. |
| No response to electrical signal | Shorted coil assembly. |
| Low flow gain | 1. Incorrect null adjustment. 2. Partially plugged orifice or filter. |
Routine maintenance focuses on preventing common faults:
The mechanical null adjustment allows you to calibrate the valve's flow null (the spool position where no flow passes to the actuator when the input signal is zero) independently of other system parameters. This is done by rotating an eccentric bushing retainer pin with an Allen wrench, which can adjust the flow null by at least ±20%. This adjustment should be performed if system components are drifting or stuck in a hardover position.
Контактное лицо: Mr. liyun
Телефон: +8615280488899